The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Abstract
The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Rheingold, H. (1991) · Cited by 1,867
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Sensor Networks for Emergency Response: Challenges and Opportunities
Lorincz, K., Malan, D. J., Fulford-Jones, T. R. F., Nawoj, A., Clavel, A., Shnayder, V., Mainland, G., Welsh, M., & Moulton, S. (2004) · IEEE Pervasive Computing · doi:10.1109/mprv.2004.18 · Cited by 1,034
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Medical instrumentation: Application and design
Undar, A., Calhoon, J. H., & Rocha, A. D. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,015
System architecture of a wireless body area sensor network for ubiquitous health monitoring
Otto, C., Milenković, A., Sanders, C., & Jovanov, E. (2005) · Journal of Multimedia · doi:10.5555/2010498.2010502 · Cited by 729
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707 · cited 2×
“[2] Anliker U, Ward JA, Lukowicz P, Troster G, Dolveck F, Baer M, et al.”
BackgroundEnhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 614
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Wearable and implantable wireless sensor network solutions for healthcare monitoring
Darwish, A., & Hassanien, A. E. (2011) · Sensors · doi:10.3390/s110605561 · Cited by 556
Smart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R., Slomian, J., Reginster, J. Y., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 448
Kakria, P., Tripathi, N. K., & Kitipawang, P. (2015) · International Journal of Telemedicine and Applications · doi:10.1155/2015/373474 · Cited by 410
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare
Andreu-Perez, J., Leff, D. R., Ip, H. M. D., & Yang, G.-Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422751 · Cited by 383
Wireless sensor network based wearable smart shirt for ubiquitous health and activity monitoring
Lee, Y.-D., & Chung, W.-Y. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.040 · Cited by 382
Elderly Fall Detection Systems: A Literature Survey
Wang, X., Ellul, J., & Azzopardi, G. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.00071 · Cited by 380
Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
Mercuri, M., Lorato, I. R., Liu, Y.-H., Wieringa, F., Hoof, C. V., & Torfs, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0258-6 · Cited by 354
Baig, M. M., GholamHosseini, H., Moqeem, A. A., Mirza, F., & Lindén, M. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0760-1 · Cited by 351
Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
Alam, M. M., Malik, H., Khan, M. I., Pardy, T., Kuusik, A., & Le Moullec, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2853148 · Cited by 272
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
Using Smartphones and Wearable Devices to Monitor Behavioral Changes During COVID-19
Sun, S., Folarin, A. A., Ranjan, Y., Rashid, Z., Conde, P., Stewart, C., Cummins, N., Matcham, F., Dalla Costa, G., Simblett, S., et al. (2020) · Journal of Medical Internet Research · doi:10.2196/19992 · Cited by 256
A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health
Sahoo, P., Thakkar, H., & Lee, M.-Y. (2017) · Sensors · doi:10.3390/s17040711 · Cited by 81
Gaura, E., Kemp, J., & Brusey, J. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2254485 · Cited by 32
A neural algorithm for the non-uniform and adaptive sampling of biomedical data
Mesin, L. (2016) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.02.004 · Cited by 22
Villarejo, M., Zapirain, B., & Zorrilla, A. (2013) · Sensors · doi:10.3390/s130506141 · Cited by 20
Piezoelectric based Biosignal Transmission using Xbee
Jalil, M., Al, M., Saleh, A., Al, O., Ahmed, S., Shakhatreh, W., & Al, M. (2018) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2018.090836
Metadata
- Authors
- Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2007-09-14
- Volume
- 30
- Issue
- 4
- Pages
- 466-477
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2065105236
- Cited by
- 423
- References
- 46
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.