Fibre-selective recording from peripheral nerves using a multiple-contact cuff: Report on pilot pig experiments
Open accessAbstract
A single cuff electrode with multiple-contacts permits fibre selective recording from peripheral nerves. This has been demonstrated in frog nerve in vitro and earth worm before. In this paper we apply this method successfully to the peripheral median nerve of pig in vivo. Compound action potentials (CAPs) were electrically excited at the median nerve close to the wrist of the forelimb. The CAPs were recorded by a recording nerve cuff located proximal to the stimulation cuff. Applying simple mathematical routines allowed for generating a profile of nerve fibre activation as a function of propagation velocity.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The ability of velocity selection recording to discriminate recorded activity by fiber type has been validated in several acute in vivo studies.
“The ability of VSR to discriminate recorded activity based on fiber type has been validated in several acute in vivo studies [123, 124, 153]; demonstrating this technique in a chronically implanted model would represent a major advancement.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [123]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
Self-citationPolyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · see citing works
Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording
Taylor, J. T., Donaldson, N., & Winter, J. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347545 · Cited by 79 · see citing works
Self-citationDesign of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · see citing works
Self-citationSingle unit conduction velocities from averaged nerve cuff electrode records in freely moving cats
Hoffer, J. A., Loeb, G. E., & Pratt, C. A. (1981) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(81)90033-9 · Cited by 73 · see citing works
Yoshida, K., Kurstjens, G. A. M., & Hennings, K. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.08.005 · Cited by 43 · see citing works
Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode
Schüettler, M., Seetohul, V., Taylor, J. T., & Donaldson, N. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260335 · Cited by 15 · see citing works
Self-citationA summary of the theory of velocity selective neural recording
Taylor, J. T., Schüettler, M., Clarke, C., et al. (2011) · doi:10.1109/iembs.2011.6091151 · Cited by 10 · see citing works
Self-citationReducing stiffness and electrical losses of high channel hybrid nerve cuff electrodes
Schüettler, M., Stieglitz, T., Gross, M., Altpeter, D., Staiger, A., Doerge, T., & Katzenberg, F. (2001) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1019054 · Cited by 7 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [7][7] Schuettler, M., Doerge, T, Wien, S.L., Becker, S., Staiger, A., Hanauer, M., Kammer, S., Stieglitz, T.: 'Cytotoxicity of Platinum Black'. Proceedings of the IFESS, pp. 343-345, 2005. -
- [10][10] Taylor J, Schuettler, M., Clarke, C., Donaldson, N.: "Improving Selectivity of Velocity Selective Nerve Cuff Recordings by Band-Pass Filtering", Transactions IEEE EMBC, 2011.
Cited by
Sorted by citations
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123 · see citing works
Self-citationImplantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50 · see citing works
Self-citationNielsen, T. N., Sevcencu, C., & Struijk, J. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278479 · Cited by 15 · see citing works
- Authors
- Schuettler, M., Seetohul, V., Rijkhoff, N. J. M., Moeller, F. V., Donaldson, N., & Taylor, J.
- Affiliations
- Imperial College London (GB)
- Aalborg University (DK)
- University College London (GB)
- University of Bath (GB)
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 3103-3106
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W1980779131
- Cited by
- 19
- References
- 9
- Citations by year
- 2024: 1 · 2022: 1 · 2021: 3 · 2020: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 4
- FWCI
- 7.23
- Type
- conference paper
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Pure (University of Bath) (publishedVersion, other-oa)
- The University of Bath Online Publications Store (The University of Bath) (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Funders
- Deutscher Akademischer Austauschdienst
- Engineering and Physical Sciences Research Council
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- peripheral nerves, median nerve, compound action potential, propagation velocity, pigs, neural recording
- MeSH terms
- Animals, Electrodes, Female, Peripheral Nerves, Swine, Models, Animal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review