The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Reconstruction of fetal brain MRI with intensity matching and complete outlier removal
Open accessAbstract
We propose a method for the reconstruction of volumetric fetal MRI from 2D slices, comprising super-resolution reconstruction of the volume interleaved with slice-to-volume registration to correct for the motion. The method incorporates novel intensity matching of acquired 2D slices and robust statistics which completely excludes identified misregistered or corrupted voxels and slices. The reconstruction method is applied to motion-corrupted data simulated from MRI of a preterm neonate, as well as 10 clinically acquired thick-slice fetal MRI scans and three scan-sequence optimized thin-slice fetal datasets. The proposed method produced high quality reconstruction results from all the datasets to which it was applied. Quantitative analysis performed on simulated and clinical data shows that both intensity matching and robust statistics result in statistically significant improvement of super-resolution reconstruction. The proposed novel EM-based robust statistics also improves the reconstruction when compared to previously proposed Huber robust statistics. The best results are obtained when thin-slice data and the correct approximation of the point spread function is used. This paper addresses the need for a comprehensive reconstruction algorithm of 3D fetal MRI, so far lacking in the scientific literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Deterministic edge-preserving regularization in computed imaging
Charbonnier, P., Blanc-Feraud, L., Aubert, G., & Barlaud, M. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.551699 · Cited by 1,301
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Scattered data interpolation with multilevel B-splines
Lee, S., Wolberg, G., & Shin, S. Y. (1997) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.620490 · Cited by 1,046
Automated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
Super-Resolution in Medical Imaging
Greenspan, H. (2008) · The Computer Journal · doi:10.1093/comjnl/bxm075 · Cited by 564
Primary cortical folding in the human newborn: an early marker of later functional development
Dubois, J., Benders, M., Borradori-Tolsa, C., Cachia, A., Lazeyras, F., Ha-Vinh Leuchter, R., Sizonenko, S. V., Warfield, S. K., Mangin, J. F., & Hüppi, P. S. (2008) · Brain · doi:10.1093/brain/awn137 · Cited by 491
Tolsa, C. B., Zimine, S., Warfield, S. K., Freschi, M., Rossignol, A. S., Lazeyras, F., Hanquinet, S., Pfizenmaier, M., & Hüppi, P. S. (2004) · Pediatric Research · doi:10.1203/01.pdr.0000128983.54614.7e · Cited by 484
Gholipour, A., Estroff, J. A., & Warfield, S. K. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2051680 · Cited by 360
Ammari, H. M., Fitzpatrick, B., Kang, H., Ruiz, M., Yu, S., & Zhang, H. F. (2018) · Mathematical surveys and monographs · doi:10.1090/surv/235/10 · Cited by 304
Early Folding Patterns and Asymmetries of the Normal Human Brain Detected from in Utero MRI
Habas, P. A., Scott, J. A., Roosta, A., Rajagopalan, V., Kim, K., Rousseau, F., Barkovich, A. J., Glenn, O. A., & Studholme, C. (2012) · Cerebral Cortex · doi:10.1093/cercor/bhr053 · Cited by 255
Registration-Based Approach for Reconstruction of High-Resolution In Utero Fetal MR Brain Images
Rousseau, F., Glenn, O. A., Iordanova, B., Rodriguez-Carranza, C., Vigneron, D. B., Barkovich, J. A., & Studholme, C. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.05.003 · Cited by 239
Jiang, S., Xue, H., Glover, A., Rutherford, M., Rueckert, D., & Hajnal, J. V. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.895456 · Cited by 199
Self-citation(2017) · CRC Press eBooks · doi:10.1201/9781439819319 · Cited by 176
Intersection Based Motion Correction of Multislice MRI for 3-D in Utero Fetal Brain Image Formation
Kim, K., Habas, P. A., Rousseau, F., Glenn, O. A., Barkovich, A. J., & Studholme, C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2030679 · Cited by 170
Local Tissue Growth Patterns Underlying Normal Fetal Human Brain Gyrification Quantified In Utero
Rajagopalan, V., Scott, J., Habas, P. A., Kim, K., Corbett-Detig, J., Rousseau, F., Barkovich, A. J., Glenn, O. A., & Studholme, C. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.5458-10.2011 · Cited by 167
Quantitative in vivo MRI measurement of cortical development in the fetus
Clouchoux, C., Kudelski, D., Gholipour, A., Warfield, S. K., Viseur, S., Bouyssi-Kobar, M., Mari, J.-L., Evans, A. C., du Plessis, A. J., & Limperopoulos, C. (2012) · Brain Structure and Function · doi:10.1007/s00429-011-0325-x · Cited by 164
Fetal MRI: techniques and protocols
Prayer, D., Brugger, P., & Prayer, L. (2004) · Pediatric Radiology · doi:10.1007/s00247-004-1246-0 · Cited by 163
Studholme, C. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124654 · Cited by 98
MR imaging methods for assessing fetal brain development
Rutherford, M., Jiang, S., Allsop, J. M., Perkins, L., Srinivasan, L., Hayat, T. T. A., Kumar, S., & Hajnal, J. V. (2008) · Developmental Neurobiology · doi:10.1002/dneu.20614 · Cited by 82
Self-citationFetal brain volumetry through MRI volumetric reconstruction and segmentation
Gholipour, A., Estroff, J. A., Barnewolt, C. E., Connolly, S. A., & Warfield, S. K. (2010) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-010-0512-x · Cited by 78
On Super-Resolution for Fetal Brain MRI
Rousseau, F., Kim, K., Studholme, C., Koob, M., & Dietemann, J. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15745-5_44 · Cited by 72
BTK: An open-source toolkit for fetal brain MR image processing
Rousseau, F., Oubel, E., Pontabry, J., Schweitzer, M., Studholme, C., Koob, M., & Dietemann, J. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.08.007 · Cited by 71
Incremental volume reconstruction and rendering for 3-D ultrasound imaging
Ohbuchi, R., Chen, D., & Fuchs, H. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.131087 · Cited by 62
A Review of Adaptive Image Representations
Gabriel Peyré, A. (2011) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2011.2120592 · Cited by 56
Advancing Fetal Brain MRI: Targets for the Future
Limperopoulos, C., & Clouchoux, C. (2009) · Seminars in Perinatology · doi:10.1053/j.semperi.2009.04.002 · Cited by 52
Kim, K., Habas, P. A., Rajagopalan, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2143724 · Cited by 39
Leemput, K. V., Maes, F., Vandermeulen, D., et al. (1999) · Cited by 19
Rajagopalan, V., Scott, J. A., Habas, P. A., Kim, K., Rousseau, F., Glenn, O. A., Barkovich, A. J., & Studholme, C. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_58 · Cited by 9
Cited by
Makropoulos, A., Robinson, E. C., Schuh, A., Wright, R., Fitzgibbon, S., Bozek, J., Counsell, S. J., Steinweg, J., Vecchiato, K., Passerat-Palmbach, J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.054 · Cited by 554
Self-citationGholipour, A., Rollins, C. K., Velasco-Annis, C., Ouaalam, A., Akhondi-Asl, A., Afacan, O., Ortinau, C. M., Clancy, S., Limperopoulos, C., Yang, E., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00525-w · Cited by 363
Multimodal surface matching with higher-order smoothness constraints
Robinson, E. C., Garcia, K., Glasser, M. F., Chen, Z., Coalson, T. S., Makropoulos, A., Bozek, J., Wright, R., Schuh, A., Webster, M., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.037 · Cited by 324
Self-citationEbner, M., Wang, G., Li, W., Aertsen, M., Patel, P. A., Aughwane, R., Melbourne, A., Doel, T., Dymarkowski, S., De Coppi, P., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116324 · Cited by 288
Fast Volume Reconstruction From Motion Corrupted Stacks of 2D Slices
Kainz, B., Steinberger, M., Wein, W., Kuklisova-Murgasova, M., Malamateniou, C., Keraudren, K., Torsney-Weir, T., Rutherford, M., Aljabar, P., Hajnal, J. V., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2415453 · Cited by 200
Self-citation
Metadata
- Authors
- Kuklisova-Murgasova, M., Quaghebeur, G., Rutherford, M. A., Hajnal, J. V., & Schnabel, J. A.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2012-12
- Volume
- 16
- Issue
- 8
- Pages
- 1550-1564
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2024251722
- Cited by
- 426
- References
- 34
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.