ISLES 2015 - A public evaluation benchmark for ischemic stroke lesion segmentation from multispectral MRI
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
&NA; Ischemic stroke is the most common cerebrovascular disease, and its diagnosis, treatment, and study relies on non‐invasive imaging. Algorithms for stroke lesion segmentation from magnetic resonance imaging (MRI) volumes are intensely researched, but the reported results are largely incomparable due to different datasets and evaluation schemes. We approached this urgent problem of comparability with the Ischemic Stroke Lesion Segmentation (ISLES) challenge organized in conjunction with the MICCAI 2015 conference. In this paper we propose a common evaluation framework, describe the publicly available datasets, and present the results of the two sub‐challenges: Sub‐Acute Stroke Lesion Segmentation (SISS) and Stroke Perfusion Estimation (SPES). A total of 16 research groups participated with a wide range of state‐of‐the‐art automatic segmentation algorithms. A thorough analysis of the obtained data enables a critical evaluation of the current state‐of‐the‐art, recommendations for further developments, and the identification of remaining challenges. The segmentation of acute perfusion lesions addressed in SPES was found to be feasible. However, algorithms applied to sub‐acute lesion segmentation in SISS still lack accuracy. Overall, no algorithmic characteristic of any method was found to perform superior to the others. Instead, the characteristics of stroke lesion appearances, their evolution, and the observed challenges should be studied in detail. The annotated ISLES image datasets continue to be publicly available through an online evaluation system to serve as an ongoing benchmarking resource (www.isles‐challenge.org). HighlightsEvaluation framework for automatic stroke lesion segmentation from MRIPublic multi‐center, multi‐vendor, multi‐protocol databases releasedOngoing fair and automated benchmark with expert created ground truth setsComparison of 14+7 groups who responded to an open challenge in MICCAISegmentation feasible in acute and unsolved in sub‐acute cases Graphical abstract Figure. No caption available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Geurts, P., Ernst, D., & Wehenkel, L. (2006) · Machine Learning · doi:10.1007/s10994-006-6226-1 · Cited by 9,300
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Self-citationAVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“images as input and includes two preprocessing steps: (1) Cor1033 rection of bias field using the N3 bias field correction algo1034 rithm (Sled et al., 1998) and (2) normalization of the inten1035 sity values of each MRI modality to the interval [0, 1], done 1036 by applying linear histogram stretching.”
MethodElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Efficient Inference in Fully Connected CRFs with Gaussian Edge Potentials
Krähenbühl, P., & Koltun, V. (2012) · arXiv · doi:10.48550/arxiv.1210.5644 · Cited by 2,908
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335 · cited 2×
“414 Second, the STAPLE algorithm (Warfield et al., 2004), which 415 performs a simultaneous truth and performance level estima416 tion, that calculates a global weight for each rater and attempts 417 to remove the negative influence of poor algorithms during ma418”
BackgroundMethod
Research works printed but not linked: 12
- Dastidar, 2000, Volumetric measurements of right cerebral hemisphere infarction: use of a semiautomatic MRI segmentation technique, Comput. Biol. Med., 30, 41, 10.1016/S0010-4825(99)00022-0 · doi:10.1016/s0010-4825(99)00022-0
- Forkert, 2013, Comparison of 10 TTP and Tmax estimation techniques for MR perfusion-diffusion mismatch quantification in acute stroke, Am. J. Neuroradiol., 34, 1697, 10.3174/ajnr.A3460 · doi:10.3174/ajnr.a3460
- Maier, O., Reyes, M., Menze, B., Handels, H. (Eds.), 2015. In: ISLES 2015: Ischemic Stroke Lesion Segmentation - Proceedings.
- Muda, 2015, Brain lesion segmentation using fuzzy C-means on diffusion-weighted imaging, ARPN J. Eng. Appl. Sci., 10
- Neumann, 2009, Interrater agreement for final infarct MRI lesion delineation, Stroke, 40, 3768, 10.1161/STROKEAHA.108.545368 · doi:10.1161/strokeaha.108.545368
- Olivot, 2009, Perfusion MRI (Tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patients, Neurology, 72, 1140, 10.1212/01.wnl.0000345372.49233.e3 · doi:10.1212/01.wnl.0000345372.49233.e3
- Prakash, 2006, Identification, segmentation, and image property study of acute infarcts in diffusion-weighted images by using a probabilistic neural network and adaptive Gaussian mixture model, Acad. Radiol., 13, 1474, 10.1016/j.acra.2006.09.045 · doi:10.1016/j.acra.2006.09.045
- Rudyanto, 2014, Comparing algorithms for automated vessel segmentation in computed tomography scans of the lung: the VESSEL12 study, Med. Image Anal., 18, 1217, 10.1016/j.media.2014.07.003 · DOI
- Salli, 2001, Contextual clustering for analysis of functional MRI data, IEEE Trans. Med. Imag., 20, 403, 10.1109/42.925293 · DOI
- Soltanian-Zadeh, 2007, Multiparametric iterative self-organizing data analysis of ischemic lesions using pre- or post-Gd T1 MRI, Cerebrovasc. Dis., 23, 91, 10.1159/000097044 · doi:10.1159/000097044
- Takasawa, 2008, How reliable is perfusion MR in acute stroke? Validation and determination of the penumbra threshold against quantitative PET, Stroke, 39, 870, 10.1161/STROKEAHA.107.500090 · doi:10.1161/strokeaha.107.500090
- Tsai, 2014, Automatic detection and quantification of acute cerebral infarct by fuzzy clustering and histographic characterization on diffusion weighted MR imaging and apparent diffusion coefficient map, Biomed. Res. Int., 2014, 13, 10.1155/2014/963032 · doi:10.1155/2014/963032
Cited by
Efficient multi-scale 3D CNN with fully connected CRF for accurate brain lesion segmentation
Kamnitsas, K., Ledig, C., Newcombe, V. F. J., Simpson, J. P., Kane, A. D., Menon, D. K., Rueckert, D., & Glocker, B. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.10.004 · Cited by 3,498
“That method perfomed less well on this challenging task (Maier et al. (2017)).”
MethodSelf-citationBakas, S., Reyes, M., Jakab, A., Bauer, S., Rempfler, M., Crimi, A., Shinohara, R. T., Berger, C., Ha, S. M., Rozycki, M., et al. (2018) · Apollo - University of Cambridge Repository · doi:10.17863/cam.38755 · Cited by 1,441
Self-citationBakas, S., Reyes, M., Jakab, A., Bauer, S., Rempfler, M., Crimi, A., Shinohara, R. T., Berger, C., Ha, S. M., Rozycki, M., et al. (2018) · arXiv · doi:10.48550/arxiv.1811.02629 · Cited by 1,441
Self-citationMedical image segmentation using deep learning: A survey
Wang, R., Lei, T., Cui, R., Zhang, B., Meng, H., & Nandi, A. K. (2022) · IET Image Processing · doi:10.1049/ipr2.12419 · Cited by 892
VoxResNet: Deep voxelwise residual networks for brain segmentation from 3D MR images
Chen, H., Dou, Q., Yu, L., Qin, J., & Heng, P.-A. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.041 · Cited by 768
Heller, N., Isensee, F., Maier-Hein, K. H., Hou, X., Xie, C., Li, F., Nan, Y., Mu, G., Lin, Z., Han, M., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101821 · Cited by 579
Self-citationAdvances in medical image analysis with vision Transformers: A comprehensive review
Azad, R., Kazerouni, A., Heidari, M., Aghdam, E. K., Molaei, A., Jia, Y., Jose, A., Roy, R., & Merhof, D. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103000 · Cited by 485
Understanding Deep Learning Techniques for Image Segmentation
Ghosh, S., Das, N., Das, I., & Maulik, U. (2020) · ACM Computing Surveys · doi:10.1145/3329784 · Cited by 476
Kwon, Y., Won, J.-H., Kim, B. J., & Paik, M. C. (2020) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2019.106816 · Cited by 424
Hi-Net: Hybrid-Fusion Network for Multi-Modal MR Image Synthesis
Zhou, T., Fu, H., Chen, G., Shen, J., & Shao, L. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2975344 · Cited by 399
Why rankings of biomedical image analysis competitions should be interpreted with care
Maier-Hein, L., Eisenmann, M., Reinke, A., Onogur, S., Stankovic, M., Scholz, P., Arbel, T., Bogunovic, H., Bradley, A. P., Carass, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07619-7 · Cited by 380
Self-citationDeep convolutional neural networks for brain image analysis on magnetic resonance imaging: a review
Bernal, J., Kushibar, K., Asfaw, D. S., Valverde, S., Oliver, A., Martí, R., & Lladó, X. (2019) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2018.08.008 · Cited by 368
Longitudinal multiple sclerosis lesion segmentation: Resource and challenge
Carass, A., Roy, S., Jog, A., Cuzzocreo, J. L., Magrath, E., Gherman, A., Button, J., Nguyen, J., Prados, F., Sudre, C. H., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.064 · Cited by 357
Self-citationDeepMedic for Brain Tumor Segmentation
Kamnitsas, K., Ferrante, E., Parisot, S., Ledig, C., Nori, A. V., Criminisi, A., Rueckert, D., & Glocker, B. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-55524-9_14 · Cited by 346
Self-citationJiao, R., Zhang, Y., Ding, L., Xue, B., Zhang, J., Cai, R., & Jin, C. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107840 · Cited by 345
Fully automatic acute ischemic lesion segmentation in DWI using convolutional neural networks
Chen, L., Bentley, P., & Rueckert, D. (2017) · NeuroImage: Clinical · doi:10.1016/j.nicl.2017.06.016 · Cited by 304
Self-citationConvolutional neural networks for multi-class brain disease detection using MRI images
Talo, M., Yildirim, O., Baloglu, U. B., Aydin, G., & Acharya, U. R. (2019) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2019.101673 · Cited by 301
A survey on U-shaped networks in medical image segmentations
Liu, L., Cheng, J., Quan, Q., Wu, F.-X., Wang, Y.-P., & Wang, J. (2020) · Neurocomputing · doi:10.1016/j.neucom.2020.05.070 · Cited by 286
A large, open source dataset of stroke anatomical brain images and manual lesion segmentations
Liew, S.-L., Anglin, J. M., Banks, N. W., Sondag, M., Ito, K. L., Kim, H., Chan, J., Ito, J., Jung, C., Khoshab, N., et al. (2018) · Scientific Data · doi:10.1038/sdata.2018.11 · Cited by 283
RETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
Deep learning based synthesis of MRI, CT and PET: Review and analysis
Dayarathna, S., Islam, K. T., Uribe, S., Yang, G., Hayat, M., & Chen, Z. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103046 · Cited by 265
Missing MRI Pulse Sequence Synthesis Using Multi-Modal Generative Adversarial Network
Sharma, A., & Hamarneh, G. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2945521 · Cited by 254
“1) ISLES2015 dataset is a publicly available database with multi-spectral MR images [46].”
InfluentialFully convolutional network ensembles for white matter hyperintensities segmentation in MR images
Li, H., Jiang, G., Zhang, J., Wang, R., Wang, Z., Zheng, W.-S., & Menze, B. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.005 · Cited by 209
“The Ischemic Stroke Lesion Segmentation Challenge (ISLES) from 2015 to 2017 organized by Maier et al. (2017) provides a platform for fair comparison of stroke lesion segmentation algorithms.”
Self-citationAutomatic Segmentation of Acute Ischemic Stroke From DWI Using 3-D Fully Convolutional DenseNets
Zhang, R., Zhao, L., Lou, W., Abrigo, J. M., Mok, V. C. T., Chu, W. C. W., Wang, D., & Shi, L. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2821244 · Cited by 209
“For example, in the well-known Ischemic Stroke Lesion Segmentation (ISLES) [10] challenge, DeepMedic [11] ranked first on the task of sub-acute ischemic stroke segmentation (SSIS), which integrated a multi-scale 3D CNN model and a fully connected conditional random field (CRF) post-processing step.”
MethodMachine Learning for Detecting Early Infarction in Acute Stroke with Non–Contrast-enhanced CT
Qiu, W., Kuang, H., Teleg, E., Ospel, J. M., Sohn, S. I., Almekhlafi, M., Goyal, M., Hill, M. D., Demchuk, A. M., & Menon, B. K. (2020) · Radiology · doi:10.1148/radiol.2020191193 · Cited by 195
ISLES 2022: A multi-center magnetic resonance imaging stroke lesion segmentation dataset
Hernandez Petzsche, M. R., de la Rosa, E., Hanning, U., Wiest, R., Valenzuela, W., Reyes, M., Meyer, M., Liew, S.-L., Kofler, F., Ezhov, I., et al. (2022) · Scientific Data · doi:10.1038/s41597-022-01875-5 · Cited by 193
“The goal of SISS (with a total of 64 cases for training and testing) was to segment subacute stroke lesions using conventional post-stroke MRI sequences, including T2 and T1 weighted imaging, fluid attenuated inversion recover (FLAIR), and diffusion weighted imaging (DWI) [26].”
Self-citationEvaluating White Matter Lesion Segmentations with Refined Sørensen-Dice Analysis
Carass, A., Roy, S., Gherman, A., Reinhold, J. C., Jesson, A., Arbel, T., Maier, O., Handels, H., Ghafoorian, M., Platel, B., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-64803-w · Cited by 185
Self-citationmustGAN: multi-stream Generative Adversarial Networks for MR Image Synthesis
Yurt, M., Dar, S. U., Erdem, A., Erdem, E., Oguz, K. K., & Çukur, T. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101944 · Cited by 171
Amin, J., Sharif, M., Yasmin, M., Saba, T., Anjum, M. A., & Fernandes, S. L. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1453-8 · Cited by 147
A systematic collection of medical image datasets for deep learning
Li, J., Zhu, G., Hua, C., Feng, M., BasheerBennamoun, Li, P., Lu, X., Song, J., Shen, P., Xu, X., et al. (2021) · arXiv · doi:10.48550/arxiv.2106.12864 · Cited by 61
Artificial intelligence in glioma imaging: Challenges and advances
Jin, W., Fatehi, M., Abhishek, K., Mallya, M., Toyota, B., & Hamarneh, G. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8131 · Cited by 55
“Brain imaging datasets (blue dots in the figure): ADNI (Alzheimer’s Disease Neuroimaging Initiative) [31], ABIDE (Autism Brain Imaging Data Exchange) [32, 33], BraTS (Brain Tumor Segmentation) [34], and ISLES (Ischemic Stroke Lesion Segmentation) [35].”
MethodUzunova, H., Ehrhardt, J., Kepp, T., & Handels, H. (2019) · Medical Imaging 2019: Image Processing · doi:10.1117/12.2511964 · Cited by 39
Self-citationLiang, Z., Guo, X., Xu, W., Ibrahim, Y., Voets, N., Pretorius, P. M., Noble, J. A., & Kamnitsas, K. (2026) · Medical Image Analysis · doi:10.1016/j.media.2025.103763 · Cited by 10
Self-citationLiang, Z., Guo, X., Noble, J. A., & Kamnitsas, K. (2024) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-72111-3_32 · Cited by 10
Self-citationFragemann, J., Ardizzone, L., Egger, J., Kleesiek, J., & Workshop, M. (2022) · doi:10.36227/techrxiv.19364897.v1 · Cited by 6
Liang, Z., Guo, X., Xu, W., Ibrahim, Y., Voets, N., Pretorius, P. M., Noble, J. A., & Kamnitsas, K. (2025) · arXiv
Self-citation
Metadata
- Authors
- Maier, O., Menze, B. H., von der Gablentz, J., Häni, L., Heinrich, M. P., Liebrand, M., Winzeck, S., Basit, A., Bentley, P., Chen, L., Christiaens, D., Dutil, F., Egger, K., Feng, C., Glocker, B., Götz, M., Haeck, T., Halme, H.-L., Havaei, M., Iftekharuddin, K. M., Jodoin, P.-M., Kamnitsas, K., Kellner, E., Korvenoja, A., Larochelle, H., Ledig, C., Lee, J.-H., Maes, F., Mahmood, Q., Maier-Hein, K. H., McKinley, R., Muschelli, J., Pal, C., Pei, L., Rangarajan, J. R., Reza, S. M. S., Robben, D., Rueckert, D., Salli, E., Suetens, P., Wang, C.-W., Wilms, M., Kirschke, J. S., Krämer, U. M., Münte, T. F., Schramm, P., Wiest, R., Handels, H., & Reyes, M.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 35
- Pages
- 250-269
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2484736472
- Cited by
- 524
- References
- 63
- FWCI
- 33.77
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- Northeastern University (20150310)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.