Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 524

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

ISLES 2015 - A public evaluation benchmark for ischemic stroke lesion segmentation from multispectral MRI

Open access
Maier, Oskar, Menze, Bjoern H., von der Gablentz, Janina, Häni, Levin, Heinrich, Mattias P., Liebrand, Matthias, Winzeck, Stefan, Basit, Abdul, Bentley, Paul, Chen, Liang, Christiaens, Daan, Dutil, Francis, Egger, Karl, Feng, Chaolu, Glocker, Ben, Götz, Michael, Haeck, Tom, Halme, Hanna-Leena, Havaei, Mohammad, Iftekharuddin, Khan M., Jodoin, Pierre-Marc, Kamnitsas, Konstantinos, Kellner, Elias, Korvenoja, Antti, Larochelle, Hugo, Ledig, Christian, Lee, Jia-Hong, Maes, Frederik, Mahmood, Qaiser, Maier-Hein, Klaus H., McKinley, Richard, Muschelli, John, Pal, Chris, Pei, Linmin, Rangarajan, Janaki Raman, Reza, Syed M.S., Robben, David, Rueckert, Daniel, Salli, Eero, Suetens, Paul, Wang, Ching-Wei, Wilms, Matthias, Kirschke, Jan S., Krämer, Ulrike M., Münte, Thomas F., Schramm, Peter, Wiest, Roland, Handels, Heinz, Reyes, Mauricio · 2017 · Medical Image Analysis

Abstract

&NA; Ischemic stroke is the most common cerebrovascular disease, and its diagnosis, treatment, and study relies on non‐invasive imaging. Algorithms for stroke lesion segmentation from magnetic resonance imaging (MRI) volumes are intensely researched, but the reported results are largely incomparable due to different datasets and evaluation schemes. We approached this urgent problem of comparability with the Ischemic Stroke Lesion Segmentation (ISLES) challenge organized in conjunction with the MICCAI 2015 conference. In this paper we propose a common evaluation framework, describe the publicly available datasets, and present the results of the two sub‐challenges: Sub‐Acute Stroke Lesion Segmentation (SISS) and Stroke Perfusion Estimation (SPES). A total of 16 research groups participated with a wide range of state‐of‐the‐art automatic segmentation algorithms. A thorough analysis of the obtained data enables a critical evaluation of the current state‐of‐the‐art, recommendations for further developments, and the identification of remaining challenges. The segmentation of acute perfusion lesions addressed in SPES was found to be feasible. However, algorithms applied to sub‐acute lesion segmentation in SISS still lack accuracy. Overall, no algorithmic characteristic of any method was found to perform superior to the others. Instead, the characteristics of stroke lesion appearances, their evolution, and the observed challenges should be studied in detail. The annotated ISLES image datasets continue to be publicly available through an online evaluation system to serve as an ongoing benchmarking resource (www.isles‐challenge.org). HighlightsEvaluation framework for automatic stroke lesion segmentation from MRIPublic multi‐center, multi‐vendor, multi‐protocol databases releasedOngoing fair and automated benchmark with expert created ground truth setsComparison of 14+7 groups who responded to an open challenge in MICCAISegmentation feasible in acute and unsolved in sub‐acute cases Graphical abstract Figure. No caption available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2016.07.009

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 12

  1. Dastidar, 2000, Volumetric measurements of right cerebral hemisphere infarction: use of a semiautomatic MRI segmentation technique, Comput. Biol. Med., 30, 41, 10.1016/S0010-4825(99)00022-0 · doi:10.1016/s0010-4825(99)00022-0
  2. Forkert, 2013, Comparison of 10 TTP and Tmax estimation techniques for MR perfusion-diffusion mismatch quantification in acute stroke, Am. J. Neuroradiol., 34, 1697, 10.3174/ajnr.A3460 · doi:10.3174/ajnr.a3460
  3. Maier, O., Reyes, M., Menze, B., Handels, H. (Eds.), 2015. In: ISLES 2015: Ischemic Stroke Lesion Segmentation - Proceedings.
  4. Muda, 2015, Brain lesion segmentation using fuzzy C-means on diffusion-weighted imaging, ARPN J. Eng. Appl. Sci., 10
  5. Neumann, 2009, Interrater agreement for final infarct MRI lesion delineation, Stroke, 40, 3768, 10.1161/STROKEAHA.108.545368 · doi:10.1161/strokeaha.108.545368
  6. Olivot, 2009, Perfusion MRI (Tmax and MTT) correlation with xenon CT cerebral blood flow in stroke patients, Neurology, 72, 1140, 10.1212/01.wnl.0000345372.49233.e3 · doi:10.1212/01.wnl.0000345372.49233.e3
  7. Prakash, 2006, Identification, segmentation, and image property study of acute infarcts in diffusion-weighted images by using a probabilistic neural network and adaptive Gaussian mixture model, Acad. Radiol., 13, 1474, 10.1016/j.acra.2006.09.045 · doi:10.1016/j.acra.2006.09.045
  8. Rudyanto, 2014, Comparing algorithms for automated vessel segmentation in computed tomography scans of the lung: the VESSEL12 study, Med. Image Anal., 18, 1217, 10.1016/j.media.2014.07.003 · doi:10.1016/j.media.2014.07.003
  9. Salli, 2001, Contextual clustering for analysis of functional MRI data, IEEE Trans. Med. Imag., 20, 403, 10.1109/42.925293 · DOI
  10. Soltanian-Zadeh, 2007, Multiparametric iterative self-organizing data analysis of ischemic lesions using pre- or post-Gd T1 MRI, Cerebrovasc. Dis., 23, 91, 10.1159/000097044 · doi:10.1159/000097044
  11. Takasawa, 2008, How reliable is perfusion MR in acute stroke? Validation and determination of the penumbra threshold against quantitative PET, Stroke, 39, 870, 10.1161/STROKEAHA.107.500090 · doi:10.1161/strokeaha.107.500090
  12. Tsai, 2014, Automatic detection and quantification of acute cerebral infarct by fuzzy clustering and histographic characterization on diffusion weighted MR imaging and apparent diffusion coefficient map, Biomed. Res. Int., 2014, 13, 10.1155/2014/963032 · doi:10.1155/2014/963032

Cited by

See all 524

Metadata

Authors
Maier, O., Menze, B. H., von der Gablentz, J., Häni, L., Heinrich, M. P., Liebrand, M., Winzeck, S., Basit, A., Bentley, P., Chen, L., Christiaens, D., Dutil, F., Egger, K., Feng, C., Glocker, B., Götz, M., Haeck, T., Halme, H.-L., Havaei, M., Iftekharuddin, K. M., Jodoin, P.-M., Kamnitsas, K., Kellner, E., Korvenoja, A., Larochelle, H., Ledig, C., Lee, J.-H., Maes, F., Mahmood, Q., Maier-Hein, K. H., McKinley, R., Muschelli, J., Pal, C., Pei, L., Rangarajan, J. R., Reza, S. M. S., Robben, D., Rueckert, D., Salli, E., Suetens, P., Wang, C.-W., Wilms, M., Kirschke, J. S., Krämer, U. M., Münte, T. F., Schramm, P., Wiest, R., Handels, H., & Reyes, M.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2017-01
Volume
35
Pages
250-269
ISSN
1361-8415 (ISSN-L)
OpenAlex
W2484736472
Cited by
524
References
63
FWCI
33.77
Type
journal article
Language
en
Open access
green
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Funders
Northeastern University (20150310)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.