The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Relaxation effects in the quantification of fat using gradient echo imaging
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds
Coleman, T. F., & Li, Y. (1996) · SIAM Journal on Optimization · doi:10.1137/0806023 · Cited by 3,320
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Two-Dimensional Phase Unwrapping: Theory, Algorithms, and Software
Ghiglia, D. C., & Pritt, M. D. (1998) · Medical Entomology and Zoology · Cited by 2,031
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
Vanhamme, L., van den Boogaart, A., & Van Huffel, S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1244 · Cited by 1,627
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Coleman, T. F., & Li, Y. (1994) · Mathematical Programming · doi:10.1007/bf01582221 · Cited by 1,135
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Coleman, T. F., & Li, Y. (1992) · Cited by 551
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S. (2005) · Radiology · doi:10.1148/radiol.2373041639 · Cited by 277
Ma, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20146 · Cited by 249
Patton, H. M., Sirlin, C., Behling, C., Middleton, M., Schwimmer, J. B., & Lavine, J. E. (2006) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000239995.58388.56 · Cited by 237
Self-citationIntroduction of fast MR imaging in the assessment of hepatic steatosis
Fishbein, M. H., Gardner, K. G., Potter, C. J., Schmalbrock, P., & Smith, M. A. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00224-x · Cited by 226
Cramér–Rao bounds for three‐point decomposition of water and fat
Pineda, A. R., Reeder, S. B., Wen, Z., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20623 · Cited by 215
Westwood, M. A., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Lorenz, C. H., Wonke, B., & Pennell, D. J. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10396 · Cited by 166
Liver Fat: Effect of Hepatic Iron Deposition on Evaluation with Opposed-Phase MR Imaging
Westphalen, A. C. A., Qayyum, A., Yeh, B. M., Merriman, R. B., Lee, J. A., Lamba, A., Lu, Y., & Coakley, F. V. (2007) · Radiology · doi:10.1148/radiol.2422052024 · Cited by 165
Venkatesan, R., Lin, W., & Haacke, E. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400412 · Cited by 151
Combination of signals from array coils using image‐based estimation of coil sensitivity profiles
Bydder, M., Larkman, D. J., & Hajnal, J. V. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10092 · Cited by 122
Self-citationIn vivo Quantitative characterization of trabecular bone by NMR
Ford, J. C., & Wehrli, F. W. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170225 · Cited by 88
Cited by
Noninvasive assessment of liver disease in patients with nonalcoholic fatty liver disease
Castera, L., Friedrich-Rust, M., & Loomba, R. (2019) · Gastroenterology · doi:10.1053/j.gastro.2018.12.036 · Cited by 1,494
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Noninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH Trials
Caussy, C., Reeder, S. B., Sirlin, C. B., & Loomba, R. (2018) · Hepatology · doi:10.1002/hep.29797 · Cited by 563
Self-citationNoureddin, M., Lam, J., Peterson, M. R., Middleton, M., Hamilton, G., Le, T.-A., Bettencourt, R., Changchien, C., Brenner, D. A., Sirlin, C., et al. (2013) · Hepatology · doi:10.1002/hep.26455 · Cited by 550
Self-citation
Metadata
- Authors
- Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 26
- Issue
- 3
- Pages
- 347-359
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2154312373
- Cited by
- 394
- References
- 21
- FWCI
- 19.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.