The DOI matches its Crossref record.
Zn-Li alloy after extrusion and drawing: Structural, mechanical characterization, and biodegradation in abdominal aorta of rat
Open accessAbstract
Zinc shows great promise as a bioabsorbable metal. Our early in vivo investigations implanting pure zinc wires into the abdominal aorta of Sprague-Dawley rats revealed that metallic zinc does not promote restenotic responses and may suppress the activities of inflammatory and smooth muscle cells. However, the low tensile strength of zinc remains a major concern. A cast billet of the Zn-Li alloy was produced in a vacuum induction caster under argon atmosphere, followed by a wire drawing process. Two phases of the binary alloy identified by x-ray diffraction include the zinc phase and intermetallic LiZn4 phase. Mechanical testing proved that incorporating 3 at.% of Li into Zn increased its ultimate tensile strength from 116 ± 13 MPa (pure Zn) to 274 ± 61 MPa while the ductility was held at 17 ± 7%. Implantation of 10 mm Zn-3Li wire segments into abdominal aorta of rats revealed an excellent biocompatibility of this material in the arterial environment. The biodegradation rate for Zn-3Li was found to be about 0.008 mm/yr and 0.045 mm/yr at 2 and 12 months, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Self-citationZinc-based biomaterials for regeneration and therapy
Su, Y., Cockerill, I., Wang, Y., Qin, Y.-X., Chang, L., Zheng, Y., & Zhu, D. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.10.009 · Cited by 417
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
The Prospects of Zinc as a Structural Material for Biodegradable Implants—A Review Paper
Katarivas Levy, G., Goldman, J., & Aghion, E. (2017) · Metals · doi:10.3390/met7100402 · Cited by 340
Self-citationCurrent status and perspectives of zinc-based absorbable alloys for biomedical applications
Hernández-Escobar, D., Champagne, S., Yilmazer, H., Dikici, B., Boehlert, C. J., & Hermawan, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.034 · Cited by 309
Additively manufactured biodegradable porous iron
Li, Y., Jahr, H., Lietaert, K., Pavanram, P., Yilmaz, A., Fockaert, L. I., Leeflang, M. A., Pouran, B., Gonzalez-Garcia, Y., Weinans, H., et al. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.07.011 · Cited by 299
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Self-citationKannan, M. B., Moore, C., Saptarshi, S., Somasundaram, S., Rahuma, M., & Lopata, A. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-15873-w · Cited by 79
Metadata
- Authors
- Zhao, S., Seitz, J.-M., Eifler, R., Maier, H. J., Guillory, R. J., Earley, E. J., Drelich, A., Goldman, J., & Drelich, J. W.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2017-07
- Volume
- 76
- Pages
- 301-312
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2594627979
- Cited by
- 251
- References
- 0
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.