Rotation sensing and gesture control of a robot joint via triboelectric quantization sensor
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In human-machine interaction, robotic hands are expected to work like human's hands and to be even more powerful or delicate in certain situations. To operate robotic hands via human gesture instead of handle or button will make this human-robot interface more natural and precise. Here, we designed a joint motion triboelectric quantization sensor (jmTQS) for constructing a robotic hand synchronous control system. Based on the ultrahigh sensitivity of a triboelectric nanogenerator (TENG) to mechanical displacement, the jmTQS designed as grating-sliding mode realized directly quantifying a joint's flexion-extension degree/speed. Through counting the pulses induced by jmTQS and signing the positive/negative of the pulses to represent flexion/extension, the joint's angular position can be determined with absolute value on the basis of the initial human-robotic synchronizing position value. In the whole operating course, the intuitionistic human-robotic hand two-dimensional motion mapping can be preserved. The minimum resolution angle of the fabricated jmTQSs is 3.8° and can be further improved by decreasing the grating width. This direct quantization and intuitionistic mapping at the sensing stage greatly simplified the signal processing and classification algorithms, which contributes to achieving the natural, high-precision and real-time interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
The grand challenges of Science Robotics
Yang, G.-Z., Bellingham, J., Dupont, P. E., Fischer, P., Floridi, L., Full, R., Jacobstein, N., Kumar, V., McNutt, M., Merrifield, R., et al. (2018) · Science Robotics · doi:10.1126/scirobotics.aar7650 · Cited by 1,177
Self-citationWen, Z., Yeh, M.-H., Guo, H., Wang, J., Zi, Y., Xu, W., Deng, J., Zhu, L., Wang, X., Hu, C., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600097 · Cited by 854
Self-citationQuaternion-Based Gesture Recognition Using Wireless Wearable Motion Capture Sensors
Alavi, S., Arsenault, D., & Whitehead, A. (2016) · Sensors · doi:10.3390/s16050605 · Cited by 47
Cited by
Dong, K., Peng, X., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.201902549 · Cited by 1,322
Self-citationZhu, M., Sun, Z., Zhang, Z., Shi, Q., He, T., Liu, H., Chen, T., & Lee, C. (2020) · Science Advances · doi:10.1126/sciadv.aaz8693 · Cited by 784
“The reported devices usually used two external materials to conduct either the contact and separation of the arch-shaped structure ( 36 ) or the sliding of grating patterned strips ( 23 ).”
Wearable Sensors‐Enabled Human–Machine Interaction Systems: From Design to Application
Yin, R., Wang, D., Zhao, S., Lou, Z., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008936 · Cited by 769
Triboelectric nanogenerator sensors for soft robotics aiming at digital twin applications
Jin, T., Sun, Z., Li, L., Zhang, Q., Zhu, M., Zhang, Z., Yuan, G., Chen, T., Tian, Y., Hou, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19059-3 · Cited by 695
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Sun, Z., Zhu, M., Shan, X., & Lee, C. (2022) · Nature Communications · doi:10.1038/s41467-022-32745-8 · Cited by 532
Wearable and Implantable Triboelectric Nanogenerators
Liu, Z., Li, H., Shi, B., Fan, Y., Wang, Z. L., & Li, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808820 · Cited by 514
Self-citationWen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Wen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Enhancement of Triboelectric Charge Density by Chemical Functionalization
Liu, Y., Mo, J., Fu, Q., Lu, Y., Zhang, N., Wang, S., & Nie, S. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004714 · Cited by 386
Progress in TENG technology—A journey from energy harvesting to nanoenergy and nanosystem
Zhu, J., Zhu, M., Shi, Q., Wen, F., Liu, L., Dong, B., Haroun, A., Yang, Y., Vachon, P., Guo, X., et al. (2020) · EcoMat · doi:10.1002/eom2.12058 · Cited by 370
Sun, H., Zhao, Y., Wang, C., Zhou, K., Yan, C., Zheng, G., Huang, J., Dai, K., Liu, C., & Shen, C. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105035 · Cited by 364
Tao, K., Chen, Z., Yu, J., Zeng, H., Wu, J., Wu, Z., Jia, Q., Li, P., Fu, Y., Chang, H., et al. (2022) · Advanced Science · doi:10.1002/advs.202104168 · Cited by 330
Self-Powered Sensors and Systems Based on Nanogenerators
Wu, Z., Cheng, T., & Wang, Z. L. (2020) · Sensors · doi:10.3390/s20102925 · Cited by 323
Self-citationShi, Q., He, T., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.002 · Cited by 318
Technology evolution from self-powered sensors to AIoT enabled smart homes
Dong, B., Shi, Q., Yang, Y., Wen, F., Zhang, Z., & Lee, C. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105414 · Cited by 313
Electronic skin as wireless human-machine interfaces for robotic VR
Liu, Y., Yiu, C., Song, Z., Huang, Y., Yao, K., Wong, T., Zhou, J., Zhao, L., Huang, X., Nejad, S. K., et al. (2022) · Science Advances · doi:10.1126/sciadv.abl6700 · Cited by 304
Zhu, M., Yi, Z., Yang, B., & Lee, C. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101016 · Cited by 295
Leveraging triboelectric nanogenerators for bioengineering
Zhang, S., Bick, M., Xiao, X., Chen, G., Nashalian, A., & Chen, J. (2021) · Matter · doi:10.1016/j.matt.2021.01.006 · Cited by 288
Self-citationZhu, M., He, T., & Lee, C. (2020) · Applied Physics Reviews · doi:10.1063/5.0016485 · Cited by 287
Recent advancements for improving the performance of triboelectric nanogenerator devices
Lone, S. A., Lim, K. C., Kaswan, K., Chatterjee, S., Fan, K.-P., Choi, D., Lee, S., Zhang, H., Cheng, J., & Lin, Z.-H. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107318 · Cited by 270
Triboelectric nanogenerators as wearable power sources and self-powered sensors
Pu, X., Zhang, C., & Wang, Z. L. (2023) · National Science Review · doi:10.1093/nsr/nwac170 · Cited by 267
Self-citationShi, Q., Zhang, Z., Chen, T., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.05.033 · Cited by 202
Shi, Q., & Lee, C. (2019) · Advanced Science · doi:10.1002/advs.201900617 · Cited by 174
Design, manufacturing and applications of wearable triboelectric nanogenerators
Wang, H., Han, M., Song, Y., & Zhang, H. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105627 · Cited by 179
Metadata
- Authors
- Pu, X., Guo, H., Tang, Q., Chen, J., Feng, L., Liu, G., Wang, X., Xi, Y., Hu, C., & Wang, Z. L.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 54
- Pages
- 453-460
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2898584555
- Cited by
- 244
- References
- 5
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.