The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Wearable sweat monitoring system with integrated micro-supercapacitors
Abstract
Abstract Flexible and attachable body fluid monitoring smart systems are considered to be one of the most important wearable electronic devices for personal health. In this work, we fabricated a wearable self-powered-like sweat monitoring system with integrated micro-supercapacitors (MSCs). The monitoring system composes of NiCo2O4/chitosan based glucose sensor, ion selective membrane based [Na+] and [K+] sensors, and NiCo2O4-based MSCs as the power source of the sensor arrays. As-fabricated NiCo2O4-based MSCs displayed excellent electrochemical performance with an energy density of 0.64 μW/cm2 at the power density of 0.09 mW/cm2. The designed wearable sweat monitoring system showed high sensitivities of 0.5 μA/μM for glucose, 0.031 nF/mM for [Na+] and 0.056 nF/mM for [K+], respectively. By further integrating with signal transduction, conditioning and wireless transmission technology (WiFi), the smart system can easily and accurately realize the real-time monitoring of perspiration displayed on individual cellphone for assessment of personal physiological state. The designed wearable smart monitoring system presented potential applications in personalized diagnostic and physiological health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Health monitoring in the home of the future
Korhonen, I., Parkka, J., & Van Gils, M. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213628 · Cited by 486
Recent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
Research works printed but not linked: 23
- Yeo, 2013, Adv. Mater., 25, 2773, 10.1002/adma.201204426 · DOI · Paper page
- Hattori, 2014, Adv. Healthc. Mater., 3, 1597, 10.1002/adhm.201400073 · DOI · Paper page
- Wang, 2017, Chem. Soc. Rev., 46, 6764, 10.1039/C7CS00278E · DOI · Paper page
- Wang, 2014, Adv. Mater., 26, 1336, 10.1002/adma.201304248 · DOI · Paper page
- Dagdeviren, 2014, Nat. Commun., 5, 4496, 10.1038/ncomms5496 · DOI · Paper page
- Chen, 2014, Nat. Commun., 5, 5028, 10.1038/ncomms6028 · DOI · Paper page
- Pang, 2015, Adv. Mater., 27, 634, 10.1002/adma.201403807 · DOI · Paper page
- Takei, 2015, Adv. Healthc. Mater., 4, 487, 10.1002/adhm.201400546 · DOI · Paper page
- Chortos, 2014, Mater. Today, 17, 321, 10.1016/j.mattod.2014.05.006 · DOI · Paper page
- Lee, 2017, Sci. Adv., 3, e1601314, 10.1126/sciadv.1601314 · DOI · Paper page
- Patterson, 2002, Acta Physiol. Scand., 174, 41, 10.1046/j.1365-201x.2002.00927.x · DOI
- Shirreffs, 1997, J. Appl. Physiol., 82, 336, 10.1152/jappl.1997.82.1.336 · DOI · Paper page
- Nakata, 2017, ACS Sens., 2, 443, 10.1021/acssensors.7b00047 · DOI · Paper page
- Li, 2017, Nano Energy, 41, 261, 10.1016/j.nanoen.2017.08.060 · DOI
- Wang, 2013, J. Mater. Chem. A, 1, 2468, 10.1039/c2ta01283a · doi:10.1039/c2ta01283a
- Han, 2015, Adv. Sci., 2, 10.1002/advs.201500067 · DOI
- Naik, 2015, RSC Adv., 5, 74585, 10.1039/C5RA13833G · DOI
- Liu, 2015, Biosens. Bioelectron., 64, 147, 10.1016/j.bios.2014.08.062 · DOI · Paper page
- Xue, 2017, Electrochim. Acta, 239, 36, 10.1016/j.electacta.2017.04.005 · DOI
- Lv, 2017, Sens. Actuators B: Chem., 248, 630, 10.1016/j.snb.2017.04.052 · DOI
- Dong, 2012, ACS Nano, 6, 3206, 10.1021/nn300097q · DOI · Paper page
- Li, 2015, Small, 11, 731, 10.1002/smll.201400830 · DOI
- Segev-Bar, 2013, ACS Nano, 7, 8366, 10.1021/nn402728g · DOI · Paper page
Cited by
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Self-citation
Metadata
- Authors
- Lu, Y., Jiang, K., Chen, D., & Shen, G.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 58
- Pages
- 624-632
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W2914796289
- Cited by
- 199
- References
- 12
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- National Natural Science Foundation of China (51672308, 61625404, 61888102)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable sweat monitoring system with integrated micro-supercapacitors. https://app.cochat.ai/papers/10.1016/j.nanoen.2019.01.084
- The paper
- Lu, Y., Jiang, K., Chen, D., & Shen, G. (2019). Wearable sweat monitoring system with integrated micro-supercapacitors. Nano Energy. https://doi.org/10.1016/j.nanoen.2019.01.084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.