Towards limb position invariant myoelectric pattern recognition using time-dependent spectral features
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 6×
“The control scheme denoted as myoelectric control employs a pattern recognition approach to discriminate between the EMG signals that belong to different arm movements (Hudgins et al., 1993).”
BackgroundMethodInfluentialA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 2×
“…from human muscles, utilizing these in developing various applications including a control source for powered prosthetic and rehabilitation devices (Englehart & Hudgins, 2003; Hudgins, Parker, & Scott, 1993; Merletti & Parker, 2004), speech recognition (Chan, Englehart, Hudgins, & Lovely, 2002;…”
MethodEEG analysis based on time domain properties
Hjorth, B. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90143-4 · Cited by 1,504
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 19×
“However before proceeding to describe our proposed method, we proceed first with a background review on feature extraction in EMG classification before linking the effect of limb position changes with variations in the EMG signal characteristics.”
BackgroundMethodInfluentialA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“The rationale for the choice of the 100 ms window size is that it is generally well-known that the total delay in any EMG-driven system needs to be kept below 300 ms to achieve real-time control (Englehart et al., 2001; Oskoei & Hu, 2007).”
BackgroundControl of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Energy supply and muscle fatigue in humans
SAHLIN, K., TONKONOGI, M., & SÖDERLUND, K. (1998) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.1998.0298f.x · Cited by 419
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Cited by
Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors
Phinyomark, A., N. Khushaba, R., & Scheme, E. (2018) · Sensors · doi:10.3390/s18051615 · Cited by 352
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
Self-citationParajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“Khushaba et al [113] recently proposed a robust spectral feature set for limb position invariance, but this has not yet been applied to real-time control.”
BackgroundMethodInfluentialShi, W.-T., Lyu, Z.-J., Tang, S.-T., Chia, T.-L., & Yang, C.-Y. (2018) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2017.11.001 · Cited by 178
Naik, G. R., Al-Timemy, A. H., & Nguyen, H. T. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2478138 · Cited by 160
“Among these are an impractically large number of EMG sensors [10], variations in limb position [3], [11] and force variation [12], [13].”
BackgroundTriwiyanto, T., Pawana, I. P. A., & Purnomo, M. H. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2999505 · Cited by 67
“Other studies assembled two or more features as the input of the classifier to improve the accuracy of machine learning [14]–[16].”
BackgroundTigrini, A., Verdini, F., Fioretti, S., & Mengarelli, A. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3320260 · Cited by 27
“…of this study are still valuable also in a real-time usage scenario, since it has been reported that spectral moments can be retrieved directly in time domain, without the need for applying the Fourier transform and thus changing the representation domain, by relying on the Parseval’s theorem [29].”
BackgroundMethod
Metadata
- Authors
- Khushaba, R. N., Takruri, M., Miro, J. V., & Kodagoda, S.
- Venue
- Neural Networks
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 55
- Pages
- 42-58
- ISSN
- 0893-6080 (ISSN-L)
- OpenAlex
- W2013463953
- Cited by
- 204
- References
- 10
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.