fMRI at 1.5, 3 and 7 T: Characterising BOLD signal changes
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
Yablonskiy, D. A., & Haacke, E. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320610 · Cited by 1,198
Triantafyllou, C., Hoge, R. D., Krueger, G., Wiggins, C. J., Potthast, A., Wiggins, G. C., & Wald, L. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.007 · Cited by 648
Experimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448 · cited 24×
“Hence it is expected that higher spatial specificity can be obtained in BOLD data acquired at high field as the intra-vascular signal contribution from draining veins is reduced (Duong et al., 2003a; Gati et al., 1997; Ogawa et al., 1998; Yacoub et al., 2001).”
InfluentialWeisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Cited by
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“Since the value of the transverse relaxation rate (R2*) and its change (ΔR2*) increases with higher MR field strengths, the signal change of the BOLD response to neuronal activity also increases (van der Zwaag et al., 2009).”
Human Primary Auditory Cortex Follows the Shape of Heschl's Gyrus
Da Costa, S., van der Zwaag, W., Marques, J. P., Frackowiak, R. S. J., Clarke, S., & Saenz, M. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2000-11.2011 · Cited by 294
Self-citationA Hitchhiker's Guide to Functional Magnetic Resonance Imaging
Soares, J. M., Magalhães, R., Moreira, P. S., Sousa, A., Ganz, E., Sampaio, A., Alves, V., Marques, P., & Sousa, N. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00515 · Cited by 272
Ultra-high field MRI: Advancing systems neuroscience towards mesoscopic human brain function
Dumoulin, S. O., Fracasso, A., van der Zwaag, W., Siero, J. C. W., & Petridou, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.028 · Cited by 223
“In addition, the amplitude of the BOLD responses increases supralinearly with field strength (van der Zwaag et al., 2009a; Yacoub et al., 2001), while the venous contribution is reduced because of the short venous T2 * (Koopmans et al., 2008; van der Zwaag et al., 2015b), leading to larger, and…”
Self-citation7‐T MR—from research to clinical applications?
Moser, E., Stahlberg, F., Ladd, M. E., & Trattnig, S. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1794 · Cited by 187
“The T1 effect can be used advantageously for arterial spin labelling (28) and, perhaps with more general impact, for MR angiography owing to improved background suppression (16).”
BackgroundImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“…leads to increased volume acquisition times (TR) necessitating compromises such as large slices, inter-slice gaps or sacrificed temporal resolution (e.g., (Bianciardi et al., 2009a, 2009b, 2009c; Poser and Norris, 2009; van der Zwaag et al., 2009a; van der Zwaag et al., 2009b; Poser et al., 2010)).”
BackgroundThe timing of the cognitive cycle
Madl, T., Baars, B. J., & Franklin, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0014803 · Cited by 116
The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2500-8 · Cited by 94
“Of the 22 studies (15 %) that did provide some sensitivity and specificity information, 7 calculated accuracy on a per patient basis [17, 26–31], 9 calculated accuracy on a per lesion basis [32–40], 4 calculated both [16, 41–43] and in two studies, sensitivity and specificity were irrelevant [44, 45], precluding a for…”
BackgroundSpadoni, A. D., Simmons, A. N., Yang, T. T., & Tapert, S. F. (2013) · The American Journal of Drug and Alcohol Abuse · doi:10.3109/00952990.2013.818680 · Cited by 30
“Although data were collected on disparate field strengths, the relative relationships between the ROIs should be proportionately scaled (67).”
Metadata
- Authors
- van der Zwaag, W., Francis, S., Head, K., Peters, A., Gowland, P., Morris, P., & Bowtell, R.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 47
- Issue
- 4
- Pages
- 1425-1434
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2040400998
- Cited by
- 281
- References
- 34
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.