CoChat

Optimization of PET–MR registrations for nonhuman primates using mutual information measures: A Multi-Transform Method (MTM)

Open access
Sandiego, Christine M., Weinzimmer, David, Carson, Richard E. · 2013 · NeuroImage
Cited by 30

The DOI matches its Crossref record.

Abstract

An important step in PET brain kinetic analysis is the registration of functional data to an anatomical MR image. Typically, PET-MR registrations in nonhuman primate neuroreceptor studies used PET images acquired early post-injection, (e.g., 0–10 min) to closely resemble the subject’s MR image. However, a substantial fraction of these registrations (~25%) fail due to the differences in kinetics and distribution for various radiotracer studies and conditions (e.g., blocking studies). The Multi-Transform Method (MTM) was developed to improve the success of registrations between PET and MR images. Two algorithms were evaluated, MTM-I and MTM-II. The approach involves creating multiple transformations by registering PET images of different time intervals, from a dynamic study, to a single reference (i.e., MR image) (MTM-I) or to multiple reference images (i.e., MR and PET images pre-registered to the MR) (MTM-II). Normalized mutual information was used to compute similarity between the transformed PET images and the reference image(s) to choose the optimal transformation. This final transformation is used to map the dynamic dataset into the animal’s anatomical MR space, required for kinetic analysis. The chosen transformed from MTM-I and MTM-II were evaluated using visual rating scores to assess the quality of spatial alignment between the resliced PET and reference. One hundred twenty PET datasets involving eleven different tracers from 3 different scanners were used to evaluate the MTM algorithms. Studies were performed with baboons and rhesus monkeys on the HR+, HRRT, and Focus-220. Successful transformations increased from 77.5%, 85.8%, to 96.7% using the 0–10 min method, MTM-I, and MTM-II, respectively, based on visual rating scores. The Multi-Transform Methods proved to be a robust technique for PET-MR registrations for a wide range of PET studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2012.08.051

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 28

  1. Baare, 2001, Quantitative genetic modeling of variation in human brain morphology, Cereb. Cortex, 11, 816, 10.1093/cercor/11.9.816 · DOI · Paper page
  2. Black, 2004, Atlas template images for nonhuman primate neuroimaging: baboon and macaque, Methods Enzymol., 385, 91, 10.1016/S0076-6879(04)85006-7 · DOI
  3. Cheverud, 1990, Heritability of brain size and surface features in rhesus macaques (Macaca mulatta), J. Hered., 81, 51, 10.1093/oxfordjournals.jhered.a110924 · DOI · Paper page
  4. Collignon, 1995, Automated multi-modality image registration based on information theory, Inf. Process. Med. Imaging, 3, 263
  5. Cosgrove, 2011, Assessing the sensitivity of [11C]P943, a novel 5-HT(1B) radioligand, to endogenous serotonin release, Synapse, 65, 1113, 10.1002/syn.20942 · DOI
  6. Davatzikos, 2001, Accuracy and sensitivity of detection of activation foci in the brain via statistical parametric mapping: a study using a PET simulator, Neuroimage, 13, 176, 10.1006/nimg.2000.0655 · DOI
  7. Gallezot, 2011, Evaluation of [(11)C]MRB for assessment of occupancy of norepinephrine transporters: studies with atomoxetine in non-human primates, Neuroimage, 56, 268, 10.1016/j.neuroimage.2010.09.040 · DOI · Paper page
  8. Gholipour, 2007, Brain functional localization: a survey of image registration techniques, IEEE Trans. Med. Imaging, 26, 427, 10.1109/TMI.2007.892508 · DOI · Paper page
  9. Graff-Guerrero, 2008, Brain region binding of the D2/3 agonist [11C]-(+)-PHNO and the D2/3 antagonist [11C]raclopride in healthy humans, Hum. Brain Mapp., 29, 400, 10.1002/hbm.20392 · DOI · Paper page
  10. Huang, 2004, A new positron emission tomography imaging agent for the serotonin transporter: synthesis, pharmacological characterization, and kinetic analysis of [11C]2-[2-(dimethylaminomethyl)phenylthio]-5-fluoromethylphenylamine ([11C]AFM), Nucl. Med. Biol., 31, 543, 10.1016/j.nucmedbio.2003.11.008 · DOI
  11. Jenkinson, 2002, Improved optimization for the robust and accurate linear registration and motion correction of brain images, Neuroimage, 17, 825, 10.1006/nimg.2002.1132 · DOI · Paper page
  12. Kiebel, 1997, MRI and PET coregistration — a cross validation of statistical parametric mapping and automated image registration, Neuroimage, 5, 271, 10.1006/nimg.1997.0265 · DOI
  13. Lehnert, 2006, Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner, Phys. Med. Biol., 51, 4003, 10.1088/0031-9155/51/16/008 · doi:10.1088/0031-9155/51/16/008
  14. Maintz, 1998, A survey of medical image registration, Med. Image Anal., 2, 1, 10.1016/S1361-8415(01)80026-8 · DOI · Paper page
  15. McLaren, 2009, A population-average MRI-based atlas collection of the rhesus macaque, Neuroimage, 45, 52, 10.1016/j.neuroimage.2008.10.058 · DOI · Paper page
  16. Myers, 2002, The application of PET–MR image registration in the brain, Br. J. Radiol., 75, S31, 10.1259/bjr.75.suppl_9.750031 · DOI
  17. Nabulsi, 2010, High-resolution imaging of brain 5-HT 1B receptors in the rhesus monkey using [11C]P943, Nucl. Med. Biol., 37, 205, 10.1016/j.nucmedbio.2009.10.007 · DOI · Paper page
  18. Nabulsi, 2011, [(11)C]GR103545: novel one-pot radiosynthesis with high specific activity, Nucl. Med. Biol., 38, 215, 10.1016/j.nucmedbio.2010.08.014 · DOI
  19. Skerl, 2006, A protocol for evaluation of similarity measures for rigid registration, IEEE Trans. Med. Imaging, 25, 779, 10.1109/TMI.2006.874963 · DOI · Paper page
  20. Studholme, 1997, Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures, Med. Phys., 24, 25, 10.1118/1.598130 · DOI · Paper page
  21. Studholme, 1999, An overlap invariant entropy measure of 3D medical image alignment, Pattern Recognit., 32, 71, 10.1016/S0031-3203(98)00091-0 · DOI · Paper page
  22. van Velden, 2009, HRRT versus HR+ human brain PET studies: an interscanner test–retest study, J. Nucl. Med., 50, 693, 10.2967/jnumed.108.058628 · DOI
  23. Wand, 2011, Naloxone-induced cortisol predicts mu opioid receptor binding potential in specific brain regions of healthy subjects, Psychoneuroendocrinology, 36, 1453, 10.1016/j.psyneuen.2011.03.019 · DOI
  24. Wang, 2007, Synthesis and preliminary biological evaluation of 3-[(18)F]fluoro-5-(2-pyridinylethynyl)benzonitrile as a PET radiotracer for imaging metabotropic glutamate receptor subtype 5, Synapse, 61, 951, 10.1002/syn.20445 · DOI
  25. Wilson, 2008, Radiosynthesis and initial evaluation of [18F]-FEPPA for PET imaging of peripheral benzodiazepine receptors, Nucl. Med. Biol., 35, 305, 10.1016/j.nucmedbio.2007.12.009 · DOI · Paper page
  26. Wong, 2010, Quantification of cerebral cannabinoid receptors subtype 1 (CB1) in healthy subjects and schizophrenia by the novel PET radioligand [11C]OMAR, Neuroimage, 52, 1505, 10.1016/j.neuroimage.2010.04.034 · DOI · Paper page
  27. Woods, 1993, MRI–PET registration with automated algorithm, J. Comput. Assist. Tomogr., 17, 536, 10.1097/00004728-199307000-00004 · DOI · Paper page
  28. Zamuner, 2012, A pharmacokinetic PET study of NK receptor occupancy, Eur. J. Nucl. Med. Mol. Imaging, 39, 226, 10.1007/s00259-011-1954-2 · DOI

Cited by

See all 30

Metadata

Authors
Sandiego, C. M., Weinzimmer, D., & Carson, R. E.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2013-01
Volume
64
Pages
571-581
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2105888777
Cited by
30
References
0
FWCI
2.89
Type
journal article
Language
en
Open access
green
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
  • National Center for Advancing Translational Sciences
  • National Institutes of Health
  • National Center for Research Resources

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimization of PET–MR registrations for nonhuman primates using mutual information measures: A Multi-Transform Method (MTM). https://app.cochat.ai/papers/10.1016/j.neuroimage.2012.08.051
The paper
Sandiego, C. M., Weinzimmer, D., & Carson, R. E. (2013). Optimization of PET–MR registrations for nonhuman primates using mutual information measures: A Multi-Transform Method (MTM). NeuroImage. https://doi.org/10.1016/j.neuroimage.2012.08.051

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.