The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Motion artifacts in functional near-infrared spectroscopy: A comparison of motion correction techniques applied to real cognitive data
Open accessAbstract
Motion artifacts are a significant source of noise in many functional near-infrared spectroscopy (fNIRS) experiments. Despite this, there is no well-established method for their removal. Instead, functional trials of fNIRS data containing a motion artifact are often rejected completely. However, in most experimental circumstances the number of trials is limited, and multiple motion artifacts are common, particularly in challenging populations. Many methods have been proposed recently to correct for motion artifacts, including principle component analysis, spline interpolation, Kalman filtering, wavelet filtering and correlation-based signal improvement. The performance of different techniques has been often compared in simulations, but only rarely has it been assessed on real functional data. Here, we compare the performance of these motion correction techniques on real functional data acquired during a cognitive task, which required the participant to speak aloud, leading to a low-frequency, low-amplitude motion artifact that is correlated with the hemodynamic response. To compare the efficacy of these methods, objective metrics related to the physiology of the hemodynamic response have been derived. Our results show that it is always better to correct for motion artifacts than reject trials, and that wavelet filtering is the most effective approach to correcting this type of artifact, reducing the area under the curve where the artifact is present in 93% of the cases. Our results therefore support previous studies that have shown wavelet filtering to be the most promising and powerful technique for the correction of motion artifacts in fNIRS data. The analyses performed here can serve as a guide for others to objectively test the impact of different motion correction algorithms and therefore select the most appropriate for the analysis of their own fNIRS experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Kalman Filtering and Neural Networks
(2001) · Wiley eBooks · doi:10.1002/0471221546 · Cited by 2,386
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Kalman Filtering: Theory and Practice Using Matlab®
S. Grewal, M., & P. Andrews, A. (2014) · doi:10.1002/9781118984987 · Cited by 2,117
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationCope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Self-citationCui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/004 · Cited by 683
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
Self-citationZhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852552 · Cited by 373
Self-citationNon-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Plichta, M. M., Heinzel, S., Ehlis, A.-C., Pauli, P., & Fallgatter, A. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.028 · Cited by 281
Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering
İzzetoğlu, M., Chitrapu, P. R., Bunce, S. C., & Onaral, B. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-16 · Cited by 164
Using near-infrared spectroscopy to assess neural activation during object processing in infants
Wilcox, T., Bortfeld, H., Woods, R., Wruck, E., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852551 · Cited by 154
Self-citationFunctional near Infrared Optical Imaging in Cognitive Neuroscience: An Introductory Review
Cutini, S., Moro, S. B., & Bisconti, S. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.969 · Cited by 151
Self-citationMotion Artifact Removal for Functional Near Infrared Spectroscopy: A Comparison of Methods
Robertson, F. C., Douglas, T. S., & Meintjes, E. M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038667 · Cited by 150
In Vivo Optical Imaging of Brain Function
Frostig, R. D. (2002) · CRC Press eBooks · doi:10.1201/9781420038491 · Cited by 143
A new method based on ICBM152 head surface for probe placement in multichannel fNIRS
Cutini, S., Scatturin, P., & Zorzi, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.030 · Cited by 115
Self-citationSelective activation of the superior frontal gyrus in task-switching: An event-related fNIRS study
Cutini, S., Scatturin, P., Menon, E., Bisiacchi, P. S., Gamberini, L., Zorzi, M., & Dell’Acqua, R. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.013 · Cited by 112
Self-citationVirtanen, J., Kotilahti, K. M., Ilmoniemi, R. J., Noponen, T., & Virtanen, J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3606576 · Cited by 100
Cutini, S., Scarpa, F., Scatturin, P., Dell’Acqua, R., & Zorzi, M. (2012) · Cerebral Cortex · doi:10.1093/cercor/bhs321 · Cited by 96
Self-citationTupak, S. V., Badewien, M., Dresler, T., Hahn, T., Ernst, L. H., Herrmann, M. J., Fallgatter, A. J., & Ehlis, A. (2012) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2012.03.009 · Cited by 94
The cortical control of cycling exercise in stroke patients: An fNIRS study
Lin, P., Chen, J. J., & Lin, S.-I. (2012) · Human Brain Mapping · doi:10.1002/hbm.22072 · Cited by 88
Noninvasive Imaging of Cerebral Activation with Diffuse Optical Tomography
Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2009) · Frontiers in neuroscience · doi:10.1201/9781420076851.ch14 · Cited by 66
Self-citationDissociation of processing of featural and spatiotemporal information in the infant cortex
Wilcox, T., Haslup, J. A., & Boas, D. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.064 · Cited by 64
Self-citationTaga, G., Watanabe, H., & Homae, F. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0238 · Cited by 46
Non-invasive optical imaging of stroke
Obrig, H., & Steinbrink, J. M. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0252 · Cited by 43
Affective perception and imagery: a NIRS study.
Köchel, A., Plichta, M. M., Schäfer, A., Leutgeb, V., Scharmüller, W., Fallgatter, A. J., & Schienle, A. (2011) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2011.03.006 · Cited by 37
Exploring the role of primary and supplementary motor areas in simple motor tasks with fNIRS
Brigadoi, S., Cutini, S., Scarpa, F., Scatturin, P., & Dell’Acqua, R. (2012) · Cognitive Processing · doi:10.1007/s10339-012-0446-z · Cited by 18
Self-citation
Cited by
Pinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Twenty years of functional near-infrared spectroscopy: introduction for the special issue
Boas, D. A., Elwell, C. E., Ferrari, M., & Taga, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.033 · Cited by 561
Self-citationTemporal Derivative Distribution Repair (TDDR): A motion correction method for fNIRS
Fishburn, F. A., Ludlum, R. S., Vaidya, C. J., & Medvedev, A. V. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.025 · Cited by 516
Best practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Metadata
- Authors
- Brigadoi, S., Ceccherini, L., Cutini, S., Scarpa, F., Scatturin, P., Selb, J., Gagnon, L., Boas, D. A., & Cooper, R. J.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 85
- Pages
- 181-191
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W1999340799
- Cited by
- 557
- References
- 32
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.