A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology
Open accessThe DOI matches its Crossref record; 212 of the 212 references it cites were found in a registry or an index.
Abstract
This year marks the 20th anniversary of functional near-infrared spectroscopy and imaging (fNIRS/fNIRI). As the vast majority of commercial instruments developed until now are based on continuous wave technology, the aim of this publication is to review the current state of instrumentation and methodology of continuous wave fNIRI. For this purpose we provide an overview of the commercially available instruments and address instrumental aspects such as light sources, detectors and sensor arrangements. Methodological aspects, algorithms to calculate the concentrations of oxy- and deoxyhemoglobin and approaches for data analysis are also reviewed. From the single-location measurements of the early years, instrumentation has progressed to imaging initially in two dimensions (topography) and then three (tomography). The methods of analysis have also changed tremendously, from the simple modified Beer-Lambert law to sophisticated image reconstruction and data analysis methods used today. Due to these advances, fNIRI has become a modality that is widely used in neuroscience research and several manufacturers provide commercial instrumentation. It seems likely that fNIRI will become a clinical tool in the foreseeable future, which will enable diagnosis in single subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical parametric maps in functional imaging: A general linear approach
Friston, K. J., Holmes, A. P., Worsley, K. J., Poline, J. ‐., Frith, C. D., & Frackowiak, R. S. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020402 · Cited by 9,688 · cited 2×
“The use of a model-based fNIRI analysis approach by means of the general linear model (GLM) methodology (Bullmore et al., 1996; Friston et al., 1995; Worsley and Friston, 1995) was reported by several authors (e.”
MethodPrinciples of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274 · cited 5×
“…source, couple the emitted light into the scalp, and measure the diffuse reflectance that re-emerges from the tissue a few centimeters distant from that source (Ferrari and Quaresima, 2012; Ferrari et al., 2004; Giacometti and Diamond, 2013; Hoshi, 2003; Strangman et al., 2002;Wolf et al., 2007).”
BackgroundInfluentialEstimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Analysis of fMRI Time-Series Revisited—Again
Worsley, K. J., & Friston, K. J. (1995) · NeuroImage · doi:10.1006/nimg.1995.1023 · Cited by 2,185
Resting-State Functional Connectivity Reflects Structural Connectivity in the Default Mode Network
Greicius, M. D., Supekar, K., Menon, V., & Dougherty, R. F. (2009) · Cerebral Cortex · doi:10.1093/cercor/bhn059 · Cited by 2,175 · cited 2×
“This component can be used to assess the so called “resting-state functional connectivity” of the brain (Greicius et al., 2009; Raichle, 2009; Sasai et al., 2012; White et al., 2009), which can be directly measured using electroencephalography (EEG) or magnetoencephalography (MEG), and indirectly…”
MethodPatterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817 · cited 4×
“• For data evaluation, some manufacturers offer proprietary software, others make their software available and others prefer the use of open-source toolboxes such as HomER2 (Huppert et al., 2009; PMILab, 2012), NIRS-SPM, or NIRFAST (Dehghani et al.”
BackgroundMethodInfluential
Cited by
Pinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Tachtsidis, I., & Scholkmann, F. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031405 · Cited by 607
“By crosstalk we mean to describe the phenomena that a genuine change in one chromophore concentration is also inducing a spurious measured concentration change in another; for a more detailed discussion of this issue see section “Selection of optimum wavelengths” in the recent review article by Scholkmann et al.4 and…”
Self-citationTwenty years of functional near-infrared spectroscopy: introduction for the special issue
Boas, D. A., Elwell, C. E., Ferrari, M., & Taga, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.033 · Cited by 561
Best practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Pinti, P., Scholkmann, F., Hamilton, A., Burgess, P., & Tachtsidis, I. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00505 · Cited by 464
Self-citationScholkmann, F., & Wolf, M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105004 · Cited by 450
Self-citationVal-Laillet, D., Aarts, E., Weber, B., Ferrari, M., Quaresima, V., Stoeckel, L. E., Alonso-Alonso, M., Audette, M., Malbert, C. H., & Stice, E. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.03.016 · Cited by 442
The NIRS Brain AnalyzIR Toolbox
Santosa, H., Zhai, X., Fishburn, F., & Huppert, T. (2018) · Algorithms · doi:10.3390/a11050073 · Cited by 440
Graph analysis of functional brain networks: practical issues in translational neuroscience
De Vico Fallani, F., Richiardi, J., Chavez, M., & Achard, S. (2014) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2013.0521 · Cited by 439
Quaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Xu, X., Shao, Q., Yao, L., Dong, Y., & Jiang, J. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.123108 · Cited by 386
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Zimeo Morais, G. A., Balardin, J. B., & Sato, J. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-21716-z · Cited by 375
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“(topography), are commercially available and largely utilized in different areas in the field of neuroscience.(25,215) Unfortunately,”
BackgroundA Review on the Use of Wearable Functional Near‐Infrared Spectroscopy in Naturalistic Environments
Pinti, P., Aichelburg, C., Gilbert, S., Hamilton, A., Hirsch, J., Burgess, P., & Tachtsidis, I. (2018) · Japanese Psychological Research · doi:10.1111/jpr.12206 · Cited by 325
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Self-citationCooperation in lovers: An fNIRS-based hyperscanning study
Pan, Y., Cheng, X., Zhang, Z., Li, X., & Hu, Y. (2017) · Human Brain Mapping · doi:10.1002/hbm.23421 · Cited by 307
Titanium Dioxide in the Service of the Biomedical Revolution
Rajh, T., Dimitrijevic, N. M., Bissonnette, M., Koritarov, T., & Konda, V. (2014) · Chemical Reviews · doi:10.1021/cr500029g · Cited by 293
NIRS-KIT: a MATLAB toolbox for both resting-state and task fNIRS data analysis
Hou, X., Zhang, Z., Zhao, C., Duan, L., Gong, Y., Li, Z., & Zhu, C. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.010802 · Cited by 290
Prefrontal cortex and executive function in young children: a review of NIRS studies
Moriguchi, Y., & Hiraki, K. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00867 · Cited by 288
Ayaz, H., Onaral, B., Izzetoglu, K., Shewokis, P. A., McKendrick, R., & Parasuraman, R. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00871 · Cited by 288
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Clinical translation of photoacoustic imaging
Park, J., Choi, S., Knieling, F., Clingman, B., Bohndiek, S., Wang, L. V., & Kim, C. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00240-y · Cited by 275
Hirsch, J., Zhang, X., Noah, J. A., & Ono, Y. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.018 · Cited by 236
“…and to analyze cross-brain synchrony during either live interpersonal interactions or delayed story-telling and listening paradigms (Cui et al., 2012; Jiang et al., 2012; Scholkmann et al., 2013; Tang et al., 2016; Kawasaki et al., 2013; Hasson et al., 2004; Dumas et al., 2010; Liu et al., 2017).”
New frontiers in time-domain diffuse optics, a review
Pifferi, A., Contini, D., Mora, A. D., Farina, A., Spinelli, L., & Torricelli, A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091310 · Cited by 245
“These tools have been already developed for the CW domain.(76) Still, wearable TD devices could provide more robust signals because of the higher tolerance to moving artifacts and superficial effects, the larger independence from background signal, and the possibility to get information out of a single optode by hosti…”
BackgroundHo, C. S. H., Lim, L. J. H., Lim, A. Q., Chan, N. H. C., Tan, R. S., Lee, S. H., & Ho, R. C. M. (2020) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2020.00378 · Cited by 221
“This is a noninvasive technique that can detect cortical oxygenation levels of hemoglobin (16), and low cortical oxygenation levels have been correlated with depressive illness.”
BackgroundInteroceptive rhythms in the brain
Engelen, T., Solcà, M., & Tallon-Baudry, C. (2023) · Nature Neuroscience · doi:10.1038/s41593-023-01425-1 · Cited by 207
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
Wang, X., Tian, F., Soni, S. S., Gonzalez-Lima, F., & Liu, H. (2016) · Scientific Reports · doi:10.1038/srep30540 · Cited by 219
“…for quantification of oxygenated and deox-ygenated hemoglobin concentrations (i.e., [HbO] and [Hb], respectively) in a variety of tissues 21 , such as the human breast 22–24 , the human prostate 25,26 , and the human brain 24,27 , in order to diagnose cancers or to map/ image functional…”
InfluentialfNIRS in the developmental sciences
Wilcox, T., & Biondi, M. (2015) · WIREs Cognitive Science · doi:10.1002/wcs.1343 · Cited by 214
Validating a functional near-infrared spectroscopy diagnostic paradigm for Major Depressive Disorder
Husain, S. F., Yu, R., Tang, T.-B., Tam, W. W., Tran, B., Quek, T. T., Hwang, S.-H., Chang, C. W., Ho, C. S., & Ho, R. C. (2020) · Scientific Reports · doi:10.1038/s41598-020-66784-2 · Cited by 213
Regensburger, A. P., Fonteyne, L. M., Jüngert, J., Wagner, A. L., Gerhalter, T., Nagel, A. M., Heiss, R., Flenkenthaler, F., Qurashi, M., Neurath, M. F., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0669-y · Cited by 203
Efficient Broadband Near‐Infrared Emission in the GaTaO4:Cr3+ Phosphor
Zhong, J., Zhuo, Y., Du, F., Zhang, H., Zhao, W., You, S., & Brgoch, J. (2022) · Advanced Optical Materials · doi:10.1002/adom.202101800 · Cited by 192
Jones, S., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D. (2016) · Artery Research · doi:10.1016/j.artres.2016.09.001 · Cited by 184
Imaging Brain Function with Functional Near-Infrared Spectroscopy in Unconstrained Environments
Balardin, J. B., Zimeo Morais, G. A., Furucho, R. A., Trambaiolli, L., Vanzella, P., Biazoli, C., & Sato, J. R. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00258 · Cited by 175
“The physiological and physical principles of the technique have been extensively described elsewhere (Obrig and Villringer, 2003; Scholkmann et al., 2014).”
BackgroundMethodPfeifer, M. D., Scholkmann, F., & Labruyère, R. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00641 · Cited by 173
“This is known to cause artifacts as well that are not eliminated by the filtering procedures we used (Scholkmann et al., 2014).”
BackgroundMethodResultSelf-citationUsing Fiberless, Wearable fNIRS to Monitor Brain Activity in Real-world Cognitive Tasks
Pinti, P., Aichelburg, C., Lind, F., Power, S., Swingler, E., Merla, A., Hamilton, A., Gilbert, S., Burgess, P., & Tachtsidis, I. (2015) · Journal of Visualized Experiments · doi:10.3791/53336 · Cited by 169
Kohl, S. H., Mehler, D. M. A., Lührs, M., Thibault, R. T., Konrad, K., & Sorger, B. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00594 · Cited by 161
A cross-brain neural mechanism for human-to-human verbal communication
Hirsch, J., Adam Noah, J., Zhang, X., Dravida, S., & Ono, Y. (2018) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsy070 · Cited by 114
“fNIRS is based on changes in spectral absorbance of both oxyhemoglobin (OxyHb) and deoxyhemoglobin (deOxyHb) detected by surfacemounted optodes (Villringer and Chance, 1997; Strangman et al., 2002; Cui et al., 2011; Ferrari and Quaresima, 2012; Scholkmann et al., 2014).”
Nozawa, T., Sakaki, K., Ikeda, S., Jeong, H., Yamazaki, S., Kawata, K. H. D. S., Kawata, N. Y. D. S., Sasaki, Y., Kulason, K., Hirano, K., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49257-z · Cited by 95
Pinti, P., Cardone, D., & Merla, A. (2015) · Scientific Reports · doi:10.1038/srep17471 · Cited by 63
A new 675 nm laser device in the treatment of facial aging: A prospective observational study
Cannarozzo, G., Fazia, G., Bennardo, L., Tamburi, F., Amoruso, G. F., Del Duca, E., & Nisticò, S. P. (2021) · Photobiomodulation Photomedicine and Laser Surgery · doi:10.1089/photob.2020.4908 · Cited by 48
“16 The energy delivered to collagen induces collagen re-generation, hence promoting the production of dermal collagen and the straightening of elastic fibers.”
Movement artefact removal from NIRS signal using multi-channel IMU data
Siddiquee, M. R., Marquez, J. S., Atri, R., Ramon, R., Perry Mayrand, R., & Bai, O. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0554-9 · Cited by 33
Yu, Q., Zhang, Z., Ludyga, S., Erickson, K. I., Cheval, B., Hou, M., Pindus, D. M., Hillman, C. H., Kramer, A. F., Falck, R. S., et al. (2025) · Advanced Science · doi:10.1002/advs.202406631 · Cited by 27
Hu, M., & Shealy, T. (2020) · Journal of Management in Engineering · doi:10.1061/(asce)me.1943-5479.0000771 · Cited by 25
Xie, H., Xu, G., Huo, C., Li, W., Zhao, H., Lv, Z., & Li, Z. (2021) · Physical Therapy · doi:10.1093/ptj/pzab140 · Cited by 16
Ward, J. A., & Pinti, P. (2019) · IEEE Pervasive Computing · doi:10.1109/mprv.2019.2898536 · Cited by 15
“Besides fMRI, brain hemodynamics can also be monitored using optical techniques, like functional near-infrared spectroscopy (fNIRS) [10].”
Exploring Neurophysiological Responses to Cross-Cultural Deepfake Videos
Khan, M. R., Naeem, S., Tariq, U., Dhall, A., Khan, M. N. A., Al Shargie, F., & Al-Nashash, H. (2023) · International Cconference on Multimodal Interaction · doi:10.1145/3610661.3617148 · Cited by 10
“Several techniques exist for detecting brain activity, for example, functional near-infrared spectroscopy [1][12], functional magnetic resonance imaging [3], electroencephalography (EEG) [5], etc. EEG was chosen as the preferred way of imaging the brain because of its portability and relatively…”
Method
Metadata
- Authors
- Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 85
- Pages
- 6-27
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2025564775
- Cited by
- 2,002
- References
- 212
- FWCI
- 50.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.