The DOI matches its Crossref record; 68 of the 69 references it cites were found in a registry or an index.
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Open accessAbstract
Perhaps more than any other "-omics" endeavor, the accuracy and level of detail obtained from mapping the major connection pathways in the living human brain with diffusion MRI depend on the capabilities of the imaging technology used. The current tools are remarkable; allowing the formation of an "image" of the water diffusion probability distribution in regions of complex crossing fibers at each of half a million voxels in the brain. Nonetheless our ability to map the connection pathways is limited by the image sensitivity and resolution, and also the contrast and resolution in encoding of the diffusion probability distribution. The goal of our Human Connectome Project (HCP) is to address these limiting factors by re-engineering the scanner from the ground up to optimize the high b-value, high angular resolution diffusion imaging needed for sensitive and accurate mapping of the brain's structural connections. Our efforts were directed based on the relative contributions of each scanner component. The gradient subsection was a major focus since gradient amplitude is central to determining the diffusion contrast, the amount of T2 signal loss, and the blurring of the water PDF over the course of the diffusion time. By implementing a novel 4-port drive geometry and optimizing size and linearity for the brain, we demonstrate a whole-body sized scanner with G(max) = 300 mT/m on each axis capable of the sustained duty cycle needed for diffusion imaging. The system is capable of slewing the gradient at a rate of 200 T/m/s as needed for the EPI image encoding. In order to enhance the efficiency of the diffusion sequence we implemented a FOV shifting approach to Simultaneous MultiSlice (SMS) EPI capable of unaliasing 3 slices excited simultaneously with a modest g-factor penalty allowing us to diffusion encode whole brain volumes with low TR and TE. Finally we combine the multi-slice approach with a compressive sampling reconstruction to sufficiently undersample q-space to achieve a DSI scan in less than 5 min. To augment this accelerated imaging approach we developed a 64-channel, tight-fitting brain array coil and show its performance benefit compared to a commercial 32-channel coil at all locations in the brain for these accelerated acquisitions. The technical challenges of developing the over-all system are discussed as well as results from SNR comparisons, ODF metrics and fiber tracking comparisons. The ultra-high gradients yielded substantial and immediate gains in the sensitivity through reduction of TE and improved signal detection and increased efficiency of the DSI or HARDI acquisition, accuracy and resolution of diffusion tractography, as defined by identification of known structure and fiber crossing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The MGH-UCLA HCP is using extremely powerful MRI gradients to generate leading-edge 3T diffusion MRI data.”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)
International Commission on Non-Ionizing Radiation Protection (2010) · Health Physics · doi:10.1097/hp.0b013e3181f06c86 · Cited by 2,167
Handbook of MRI Pulse Sequences
Bernstein, M. A., King, K. F., & Zhou, X. J. (2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,641
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Self-citationLin, J., Saunders, R. A., Schulmeister, K., Söderberg, P. G., Stuck, B. E., Swerdlow, A. J., Taki, M., Veyret, B., Ziegelberger, G., Repacholi, M. H., et al. (2010) · HAL · Cited by 1,261
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,229
Self-citation7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Regularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Research works printed but not linked: 1
- Moeller, 2008, fMRI with 16 fold reduction using multibanded multislice sampling, Proc. of ISMRM, 16, 2366
Cited by
Sorted by citations
Items 401–500 of 533
Practical considerations of diffusion-weighted MRS with ultra-strong diffusion gradients
Davies‐Jenkins, C. W., Döring, A., Fasano, F., Kleban, E., Mueller, L., Evans, J., Afzali, M., Jones, D. K., Ronen, I., Branzoli, F., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1258408 · Cited by 4
Tendler, B. C. (2025) · Scientific Reports · doi:10.1038/s41598-025-87377-x · Cited by 4
Q-Space Modeling in Diffusion-Weighted MRI
Aganj, I., Sapiro, G., & Harel, N. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-397025-1.00293-1 · Cited by 4
Olson, D. V., Nencka, A. S., Arpinar, V. E., & Muftuler, L. T. (2019) · NMR in Biomedicine · doi:10.1002/nbm.4162 · Cited by 5
Lee, C., Bennett, K. M., Debbins, J. P., Choi, I.-Y., & Lee, P. (2021) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2021.10.001 · Cited by 4
Kassahun, H. B., Alsharafi, S. S., Badawi, A., & El‐Sharkawy, A. M. (2022) · IEEE Access · doi:10.1109/access.2022.3210194 · Cited by 4
Liu, S., Zhang, J., Shi, D., & Guo, H. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29685 · Cited by 4
Tax, C. M. W., Genc, S., MacIver, C., Nilsson, M., Wardle, M., Szczepankiewicz, F., Jones, D. K., & Peall, K. J. (2023) · NeuroImage Clinical · doi:10.1016/j.nicl.2023.103419 · Cited by 4
Evaluation of kernel low-rank compressed sensing in preclinical diffusion magnetic resonance imaging
de Souza, D. A. R., Mathieu, H., Deloulme, J., & Barbier, E. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1172830 · Cited by 4
Connectome 2.0: Cutting-Edge Hardware Ushers in New Opportunities for Computational Diffusion MRI
Yendiki, A., Witzel, T., & Huang, S. Y. (2020) · Mathematics and visualization · doi:10.1007/978-3-030-52893-5_1 · Cited by 4
Self-citationDBS imaging methods III: Estimating the electric field and volume of tissue activated
Butenko, K., & van Rienen, U. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821861-7.00021-x · Cited by 4
Mapping the impact of nonlinear gradient fields with noise on diffusion MRI
Kanakaraj, P., Cai, L. Y., Rheault, F., Yeh, F.-C. F., Rogers, B. P., Schilling, K. G., & Landman, B. A. (2023) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2023.01.004 · Cited by 4
Interpolation on the Manifold of K Component GMMs
Kim, H. J., Adluru, N., Banerjee, M., Vemuri, B. C., & Singh, V. (2015) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.330 · Cited by 4
Shan, Y., Wang, Z., Fan, X.-T., Zhang, H., Ren, L., Wei, P., & Zhao, G. (2019) · BMC Neurology · doi:10.1186/s12883-019-1537-6 · Cited by 4
Emerging Techniques for the Personalization of Deep Brain Stimulation Programming
Santyr, B. G., Boutet, A., Ajala, A., Germann, J., Qiu, J., Fasano, A. A., Lozano, A. M., & Kucharczyk, W. (2025) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/cjn.2025.29 · Cited by 3
Arends, G. C., Versteeg, E., Luca, A. D., Fauvel, M., Roos, T., Klomp, D. W. J., Froeling, M., Siero, J. C. W., & Tax, C. M. W. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30613 · Cited by 3
Multi-modal Monte Carlo MRI simulator of tissue microstructure
Cottaar, M., Zheng, Z., Miller, K. L., Tendler, B. C., & Jbabdi, S. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1177 · Cited by 3
The turbulent brain: Modeling vortex interactions for understanding human cognition
Deco, G., Perl, Y. S., Feng, J., & Kringelbach, M. L. (2026) · Network Neuroscience · doi:10.1162/netn.a.554 · Cited by 3
Quantum‐Like Dynamics in Whole‐Brain Models of the Human Connectome
Deco, G., Perl, Y. S., Greenstein, N., Chandaria, S., Scholes, G. D., & Kringelbach, M. L. (2026) · Advanced Science · doi:10.1002/advs.77103 · Cited by 3
State-dependent signal flow hierarchy in the human cerebral cortex
Oh, Y., Ann, Y., Lee, J., Ito, T., Froudist‐Walsh, S., Paquola, C., Milham, M. P., Spreng, R. N., Margulies, D. S., Bernhardt, B. C., et al. (2026) · Nature Neuroscience · doi:10.1038/s41593-026-02389-8 · Cited by 3
Li, G., Ma, X., Li, S., Ye, X., Börnert, P., Zhou, X. J., & Guo, H. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29633 · Cited by 3
Babaloo, R., & Atalar, E. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30109 · Cited by 3
Short association fibres form topographic sheets in the human V1–V2 processing stream
Attar, F. M., Kirilina, E. P., Chaimow, D., Haenelt, D., Schneider, C., Edwards, L., Pine, K., Jäger, C., Reimann, K., Pohlmann, A., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00498 · Cited by 3
Liu, Y., Kara, D., Garrett, T., Chen, S., Wee, D., Jin, N., Speier, P., Nakagawa, H., Santangeli, P., Bolen, M. A., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30485 · Cited by 3
Feinberg, D. A., Ma, S. J., Walker, E., Beckett, A. J. S., Rattenbacher, D., Rummert, E., Dietz, P., Davids, M., & Boulant, N. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30523 · Cited by 3
Self-citationParís, G., Pieciak, T., Jones, D. K., Aja‐Fernández, S., Tristán‐Vega, A., & Veraart, J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70035 · Cited by 5
Researching Fiber Networks: Computational Modeling of Complex Fibrous Tissue Geometries
Makarov, S. N., Pascual‐Leone, Á., & Nummenmaa, A. R. (2017) · IEEE Pulse · doi:10.1109/mpul.2017.2701490 · Cited by 3
Krijnen, E. A., Ngamsombat, C., George, I. C., Yu, F. F., Fan, Q., Tian, Q., Huang, S. Y., & Klawiter, E. C. (2023) · Multiple Sclerosis Journal - Experimental Translational and Clinical · doi:10.1177/20552173221147620 · Cited by 3
Caron, A. V., Shmuel, A., Hao, Z., & Descoteaux, M. (2023) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2023.1191200 · Cited by 3
Modeling brain network flexibility in networks of coupled oscillators: a feasibility study
Chinichian, N., Lindner, M., Yanchuk, S., Schwalger, T., Schöll, E., & Berner, R. (2024) · Scientific Reports · doi:10.1038/s41598-024-55753-8 · Cited by 3
Mapping short association fibre connectivity up to V3 in the human brain in vivo
Attar, F. M., Kirilina, E. P., Haenelt, D., Trampel, R., Pine, K., Edwards, L., & Weiskopf, N. (2024) · Cerebral Cortex · doi:10.1093/cercor/bhae279 · Cited by 3
Neuroanatomy and lesion networks of central poststroke pain
Karoam, H. A., Bruss, J., Champoux, K. L., Lemos, M. D., Faillenot, I., de Andrade, D. C., Hwang, K., Bayman, E. O., Vaidya, J. G., Gordon, E. M., et al. (2025) · Pain · doi:10.1097/j.pain.0000000000003618 · Cited by 3
Luo, C., Wang, H., Liu, Y., Xie, T., Chen, G., Jin, Q., Liang, D., & Cui, Z. (2025) · Medical Physics · doi:10.1002/mp.17924 · Cited by 3
Imaging White Matter Anatomy for Brain Tumor Surgery
Pujol, S. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800870-6.00004-2 · Cited by 3
Temporal Resolution and Spatial Resolution of fMRI
Bandettini, P. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-397025-1.00020-8 · Cited by 4
Rosenberg, J. T., Grant, S. C., & Topgaard, D. (2022) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2022.107256 · Cited by 3
Advanced Physiologic Imaging: Diffusion – Theory and Applications
LaViolette, P. S. (2019) · Springer eBooks · doi:10.1007/978-3-030-27359-0_6 · Cited by 3
Advanced analysis of diffusion MRI data
Gu, X. (2019) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-161288 · Cited by 4
Dávid, S., Mesri, H. Y., Viergever, M. A., & Leemans, A. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/755140 · Cited by 3
Ding, Q., Li, L., Tong, Q., He, H., Gao, B., & Xia, L. (2024) · Brain Research · doi:10.1016/j.brainres.2024.149114 · Cited by 2
Svátková, A., Pasternak, O., Eisengart, J. B., Rudser, K. D., Bednařík, P., Mueller, B. A., Delaney, K. A., Shapiro, E., Whitley, C. B., & Nestrašil, I. (2025) · Journal of Inherited Metabolic Disease · doi:10.1002/jimd.12830 · Cited by 2
Klein, V., Edmonson, J., Davids, M., Ferris, N. G., Gebhardt, M., Rattenbacher, D., van den Brink, J. S., Steckner, M., Wald, L. L., & Guérin, B. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70130 · Cited by 2
Self-citationA Nonlinear Single Channel Gradient Insert for Prostate Diffusion Imaging
Elsaid, N., Zhang, Z., Fettahoglu, A., Sun, C., Simone, A. D., Nixon, T. W., Dewdney, A., Peters, D. C., Weinreb, J. C., Constable, R. T., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70125 · Cited by 2
Goldway, N., Markovits, T., Fine, N. B., Fruchtman-Steinbok, T., Gurevitch, G., Deco, G., Sharon, H., & Hendler, T. (2025) · Biological Psychiatry Global Open Science · doi:10.1016/j.bpsgos.2025.100655 · Cited by 2
Acquisition, image quality, and PI-RADS agreement of ultrahigh-gradient DWI in prostate 3-T MRI
Bischoff, L. M., Endler, C., Krausewitz, P., Ellinger, J., Klümper, N., Isaak, A., Mesropyan, N., Kravchenko, D., Kuetting, D. L. R., Sprinkart, A. M., et al. (2026) · European Radiology Experimental · doi:10.1186/s41747-026-00684-4 · Cited by 2
Learning engages transient and sustained cellular mechanisms in the human brain
Griffa, G., Palombo, M., Yeffal, A., Lee, H., Solano, A., Huang, S. Y., & Della‐Maggiore, V. (2026) · PLoS Biology · doi:10.1371/journal.pbio.3003861 · Cited by 3
Connectomic Determinants of Subcallosal Cingulate Deep Brain Stimulation for Depression
Song, H. N., Choi, K. S., Kopell, B. H., Figee, M., de Bruin, J., Cha, J., Riva‐Posse, P., Boutet, A., Elias, G. J. B., Germann, J., et al. (2026) · American Journal of Psychiatry · doi:10.1176/appi.ajp.20250449 · Cited by 2
Fast multi-compartment Microstructure Fingerprinting in brain white matter
Dessain, Q., Fuchs, C., Macq, B. M. M., & Rensonnet, G. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1400499 · Cited by 3
Zhang, T., Song, J., Chen, C., Li, R., Li, Y., Sun, Y., Fang, T., Xu, W., Tian, H., & Zhuo, C. (2020) · Brain and Behavior · doi:10.1002/brb3.1992 · Cited by 2
Kanakaraj, P., Cai, L. Y., Yao, T., Rheault, F., Rogers, B. P., Anderson, A. W., Schilling, K. G., & Landman, B. A. (2023) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2023.03.014 · Cited by 2
Prediction of experimental cardiac magnetostimulation thresholds using pig‐specific body models
Klein, V., Davids, M., Vendramini, L., Ferris, N. G., Schad, L. R., Sosnovik, D. E., Nguyen, C. T., Wald, L. L., & Guérin, B. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29717 · Cited by 2
Self-citationDiffusion MRI Anisotropy: Modeling, Analysis and Interpretation
Fick, R., Pizzolato, M., Wassermann, D., & Rachid Deriche, B. (2017) · Mathematics and visualization · doi:10.1007/978-3-319-61358-1_9 · Cited by 2
Yang, Z., Zhao, B., Pei, Y., Yang, B., & Lu, H. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.07.006 · Cited by 2
Hua, Y., Yeo, D. T. B., & Foo, T. (2021) · European Microwave Conference (EuMC) · doi:10.23919/eumc48046.2021.9338172 · Cited by 2
Connectomic deep brain stimulation in obsessive compulsive disorder
Baldermann, J. C. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821861-7.00025-7 · Cited by 2
Brau, A. C. S., Hardy, C. J., & Schenck, J. F. (2015) · Springer eBooks · doi:10.1007/978-3-319-22141-0_8 · Cited by 2
Structure tensor informed fibre tractography at 3T
Chan, K., Norris, D. G., & Marques, J. P. (2018) · Human Brain Mapping · doi:10.1002/hbm.24283 · Cited by 2
Postoperative MRI Applications in Patients with DBS
Germann, J., Gouveia, F. V., Wong, E. H. Y., & Horn, A. (2022) · Springer eBooks · doi:10.1007/978-3-031-16348-7_6 · Cited by 2
Rensonnet, G., Adam, L., & Macq, B. M. M. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2107.10657 · Cited by 2
Shi, D., Li, S., Liu, F., Jiang, X., Wu, L., Chen, L., Zheng, Q., Bao, H., Guo, H., & Xu, J. (2024) · PubMed · doi:10.48550/arxiv.2408.01918 · Cited by 2
Jallais, M., & Palombo, M. (2024) · eLife · doi:10.7554/elife.101069.2 · Cited by 2
Keum, J., Yoon, J. H., Garwood, M., & Park, J. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70032 · Cited by 1
Zhao, Y., Wang, M., Lyu, M., Wu, E. X., & Liu, Y. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108701 · Cited by 1
The Effect of Voxel Volume and Voxel Shape on Cardiac Diffusion Tensor Imaging Metrics
Hannum, A. J., Cork, T. E., Setsompop, K., & Ennis, D. B. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70189 · Cited by 1
Self-citationOlsson, V., Mortensen, F., Ljungberg, E., Testud, F., Wirestam, R., Molendowska, M., & Szczepankiewicz, F. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70422 · Cited by 1
VERIFICATION OF MAGNETIC RESOANCE IMAGING TRACTOGRAPHY RESULTS AND DETECTION OF DAMAGED AXONAL PATHS
Konopleva, L. V., Nedopekin, O. V., Mardihanova, D. V., Haidarova, A. R., & Il'yasov, K. A. (2016) · Russian Electronic Journal of Radiology · doi:10.21569/2222-7415-2016-6-2-6-15 · Cited by 1
High-resolution diffusion imaging in the unfixed post-mortem infant brain at 7 T
Wu, W., Rieger, S. W., Baxter, L., Adams, E., Andersson, J., Cobo, M. M., Andritsou, F., Bastiani, M., Fry, R. E., Frost, R., et al. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00069 · Cited by 1
Zhang, Z., Elsaid, N., Nixon, T. W., Dewdney, A., Peters, D. C., Weinreb, J. C., Sprenkle, P. C., Constable, R. T., & Galiana, G. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70252 · Cited by 1
Congenital blindness reduces myelination in human visual cortex
Stroh, A., Edwards, L., Haenelt, D., Attar, F. M., Pine, K., Trampel, R., Marcin Szwed, A., & Weiskopf, N. (2026) · Science Advances · doi:10.1126/sciadv.aec2348 · Cited by 2
Roebroeck, A. F. (2021) · Springer eBooks · doi:10.1007/978-3-030-59797-9_6 · Cited by 1
Gardner, A. J., Iverson, G. L., van Donkelaar, P., Ainslie, P. N., & Stanwell, P. (2015) · Oxford University Press eBooks · doi:10.1093/oxfordhb/9780199896585.013.12 · Cited by 1
A power efficient actively shielded two-channel transverse MRI gradient coil numerical design
Kassahun, H. B., Alsharafi, S. S., Badawi, A., & El‐Sharkawy, A. M. (2023) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2023.107526 · Cited by 1
Diffusion MRI acquisition for tractography: Diffusion encoding
Campbell, J. S. W., Baete, S. H., Cohen‐Adad, J., Tournier, J., Szczepankiewicz, F., Beaulieu, C., Baron, C. A., Mani, M., Setsompop, K., Liao, C., et al. (2025) · Elsevier eBooks · doi:10.1016/b978-0-12-818894-1.00001-x · Cited by 1
Self-citationLearning Global Brain Microstructure Maps Using Trainable Sparse Encoders
Rafael‐Patiño, J., Baraković, M., Girard, G., Daducci, A., & Thiran, J. (2019) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2019.8803733 · Cited by 1
Cytoarchitecture Measurements in Brain Gray Matter Using Likelihood-Free Inference
Jallais, M., Rodrigues, P. L. C., Gramfort, A., & Wassermann, D. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-78191-0_15 · Cited by 1
(2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28594 · Cited by 1
Submillimeter T2 weighted BOLD fMRI of human visual cortex
Kemper, V. G. (2016) · Research Publications (Maastricht University) · doi:10.26481/dis.20160421vk · Cited by 1
Wu, W., Baxter, L., Rieger, S. W., Adams, E., Andersson, J., Andrade, M. C., Andritsou, F., Bastiani, M., Fry, R. E., Frost, R., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.06.24.449666 · Cited by 1
Schulte, J., Senden, M., Deco, G., Kobeleva, X., & Zamora‐López, G. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.07.07.548139 · Cited by 1
Jallais, M., & Palombo, M. (2024) · eLife · doi:10.7554/elife.101069.1 · Cited by 1
Distinct cellular processes drive motor skill learning in the human brainPreprint
Griffa, G., Palombo, M., Yeffal, A., Lee, H., Huang, S. Y., & Della‐Maggiore, V. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.09.22.677842 · Cited by 1
The Virtual Brain Ontology: A Digital Knowledge Framework for Reproducible Brain Network ModelingPreprint
Martin, L., Bülau, K., Pille, M., Schmitt, R. A., Huettl, C., Meier, J. M., Taher, H., Perdikis, D., Schirner, M., Stefanovski, L., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.11.19.689211 · Cited by 1
FDTest: Fluctuation-Dissipation Theorem as a Test for Memory Effects in Brain DynamicsPreprint
Geli, S., Monti, J. M., Ponce‐Alvarez, A., Deco, G., & Perl, Y. S. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2025.12.02.691886 · Cited by 1
Mesoscopic mapping of the human structural connectome using high-performance global tractography
Legeay, S. (2025) · theses.fr (ABES) · doi:10.70675/f036d118z8937z4350zb52cz2c55acdaa577 · Cited by 1
MRI and fMRI Optimizations and Applications
Ciris, P. A., & Constable, R. T. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-397025-1.00021-x
Disease in Patients with Multiple s clerosis Using high-gradient- Diffusion M
Huang, S. Y., Tobyne, S. M., Witzel, T., Wald, L. L., McNab, J. A., & Klawiter, E. C. (2016)
Self-citationHoltrop, J. L. (2016) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Diffusion Magnetic Resonance Imaging in Diffuse Low-Grade Gliomas
Pujol, S. (2017) · Springer eBooks · doi:10.1007/978-3-319-55466-2_20
Elumalai, G., Syed, I. S., Chatterjee, H., Brown, V. L. C., Sober, L. A., Ghanta, N. A. S. V., Ghanta, V., Chandrasekhar, P., Venkatesan, A., Sewram, N., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/483628
Olfactory Spatial Attention: Neural Structural Connectivity RevealedPreprint
Elumalai, G., Chatterjee, H., Syed, I. S., Brown, V. L. C., Sober, L. A., Ghanta, N. A. S. V., Chandrasekhar, P., Venkatesan, A., Sewram, N., Muthukumaran, N. R., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/483446
Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRIPreprint
Hansen, C. B., Rogers, B. P., Schilling, K. G., Nath, V., Blaber, J. A., Irfanoglu, O., Barnett, A., Pierpaoli, C., Anderson, A. W., & Landman, B. A. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.18.102558
Physics of Advanced Diffusion Imaging
Venkataraman, A., & Zhong, J. (2021) · Springer eBooks · doi:10.1007/978-3-030-62120-9_7
Neuroscience: Turbulent times for brain information processing
Bondanelli, G., & Panzeri, S. (2021) · Current Biology · doi:10.1016/j.cub.2021.09.006
Fernandez-Iriondo, I., Sierra, B., Martínez‐Otzeta, J. M., Jiménez-Marín, A., Bonifazi, P., Yurramendi, Y., & Cortés, J. M. (2021) · International Conference on Computational Intelligence and Applications (ICCIA) · doi:10.1109/iccia52886.2021.00062
Technology for Ultrahigh Field Imaging
Uǧurbil, K. (2022) · Wiley eBooks · doi:10.1002/9783527827244.ch4
Li, W., & Mouli, S. K. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28531
Wichtmann, B. D., Fan, Q., Eskandarian, L., Witzel, T., Attenberger, U. I., Pieper, C. C., Schad, L. R., Rosen, B. R., Wald, L. L., Huang, S. Y., et al. (2022) · Human Brain Mapping · doi:10.1002/hbm.26143
Self-citationWITHDRAWN: Infratentorial Morphometry and Deep Brain Stimulation Outcome in Cervical DystoniaPreprint
Andrews, L., Keller, S. S., Osman‐Farah, J., Bhojak, M., & Macerollo, A. (2023) · medRxiv · doi:10.1101/2023.01.17.23284553
Mapping the impact of approximate gradient nonlinearity fields correction on tractography
Kanakaraj, P., Rheault, F., Cai, L. Y., Newlin, N. R., Yeh, F.-C. F., Rogers, B. P., Schilling, K. G., & Landman, B. A. (2023) · SPIE Medical Imaging: Image Processing · doi:10.1117/12.2653884
Metadata
- Authors
- Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., Cauley, S. F., Tountcheva, V., Matschl, V., Lenz, V. H., Heberlein, K., Potthast, A., Thein, H., Van Horn, J., Toga, A., Schmitt, F., Lehne, D., Rosen, B. R., Wedeen, V., & Wald, L. L.
- Affiliations
- Harvard University (US)
- Siemens Healthineers (Germany) (DE)
- University of California, Los Angeles (US)
- Corresponding author
- Wald, L.L.
- ORCID
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-10
- Volume
- 80
- Pages
- 220-233
- ISSN
- 1053-8119 (ISSN-L)
- PMC
- PMC3725309
- OpenAlex
- W1987263024
- Cited by
- 545
- References
- 69
- Citations by year
- 2026: 28 · 2025: 49 · 2024: 41 · 2023: 44 · 2022: 42 · 2021: 61 · 2020: 53 · 2019: 39 · 2018: 39 · 2017: 40 · 2016: 37 · 2015: 51 · 2014: 15 · 2013: 6
- FWCI
- 28.20
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- PolyPublie (École Polytechnique de Montréal) (submittedVersion)
- Funders
- National Institutes of Health, NIH Blueprint Initiative for Neuroscience Research (U01MH093765, P41EB015896, K99/R00EB012107)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- diffusion MRI, Human Connectome Project, compressed sensing, diffusion spectrum imaging, high angular resolution diffusion imaging, signal-to-noise ratio, crossing fibers, diffusion tractography
- MeSH terms
- Animals, Brain, Humans, Image Enhancement, Models, Anatomic, Models, Neurological, Nerve Net, Diffusion Tensor Imaging, Connectome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review