The DOI matches its Crossref record; 68 of the 69 references it cites were found in a registry or an index.
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Open accessAbstract
Perhaps more than any other "-omics" endeavor, the accuracy and level of detail obtained from mapping the major connection pathways in the living human brain with diffusion MRI depend on the capabilities of the imaging technology used. The current tools are remarkable; allowing the formation of an "image" of the water diffusion probability distribution in regions of complex crossing fibers at each of half a million voxels in the brain. Nonetheless our ability to map the connection pathways is limited by the image sensitivity and resolution, and also the contrast and resolution in encoding of the diffusion probability distribution. The goal of our Human Connectome Project (HCP) is to address these limiting factors by re-engineering the scanner from the ground up to optimize the high b-value, high angular resolution diffusion imaging needed for sensitive and accurate mapping of the brain's structural connections. Our efforts were directed based on the relative contributions of each scanner component. The gradient subsection was a major focus since gradient amplitude is central to determining the diffusion contrast, the amount of T2 signal loss, and the blurring of the water PDF over the course of the diffusion time. By implementing a novel 4-port drive geometry and optimizing size and linearity for the brain, we demonstrate a whole-body sized scanner with G(max) = 300 mT/m on each axis capable of the sustained duty cycle needed for diffusion imaging. The system is capable of slewing the gradient at a rate of 200 T/m/s as needed for the EPI image encoding. In order to enhance the efficiency of the diffusion sequence we implemented a FOV shifting approach to Simultaneous MultiSlice (SMS) EPI capable of unaliasing 3 slices excited simultaneously with a modest g-factor penalty allowing us to diffusion encode whole brain volumes with low TR and TE. Finally we combine the multi-slice approach with a compressive sampling reconstruction to sufficiently undersample q-space to achieve a DSI scan in less than 5 min. To augment this accelerated imaging approach we developed a 64-channel, tight-fitting brain array coil and show its performance benefit compared to a commercial 32-channel coil at all locations in the brain for these accelerated acquisitions. The technical challenges of developing the over-all system are discussed as well as results from SNR comparisons, ODF metrics and fiber tracking comparisons. The ultra-high gradients yielded substantial and immediate gains in the sensitivity through reduction of TE and improved signal detection and increased efficiency of the DSI or HARDI acquisition, accuracy and resolution of diffusion tractography, as defined by identification of known structure and fiber crossing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The MGH-UCLA HCP is using extremely powerful MRI gradients to generate leading-edge 3T diffusion MRI data.”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional tracking of axonal projections in the brain by magnetic resonance imaging
Mori, S., Crain, B. J., Chacko, V. P., & van Zijl, P. C. M. (1999) · Annals of Neurology · doi:10.1002/1531-8249(199902)45:2 · Cited by 3,513
GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)
International Commission on Non-Ionizing Radiation Protection (2010) · Health Physics · doi:10.1097/hp.0b013e3181f06c86 · Cited by 2,167
Handbook of MRI Pulse Sequences
Bernstein, M. A., King, K. F., & Zhou, X. J. (2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,641
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Self-citationLin, J., Saunders, R. A., Schulmeister, K., Söderberg, P. G., Stuck, B. E., Swerdlow, A. J., Taki, M., Veyret, B., Ziegelberger, G., Repacholi, M. H., et al. (2010) · HAL · Cited by 1,261
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,229
Self-citation7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Regularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Deterministic and probabilistic tractography based on complex fibre orientation distributions
Descoteaux, M., Deriche, R., Knosche, T. R., & Anwander, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004424 · Cited by 698
Triantafyllou, C., Hoge, R. D., Krueger, G., Wiggins, C. J., Potthast, A., Wiggins, G. C., & Wald, L. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.007 · Cited by 648
Self-citationBreuer, F., Blaimer, M., Heidemann, R. M., Mueller, M. F., Griswold, M. A., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20401 · Cited by 637
Tournier, J., Yeh, C., Calamante, F., Cho, K.-H., Connelly, A., & Lin, C. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.002 · Cited by 591
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 590
Image reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 512
Measurement of fiber orientation distributions using high angular resolution diffusion imaging
Anderson, A. W. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20667 · Cited by 461
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 442
Self-citationRobson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 441
Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
Özarslan, E., Shepherd, T. M., Vemuri, B. C., Blackband, S. J., & Mareci, T. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.024 · Cited by 388
Q‐ball reconstruction of multimodal fiber orientations using the spherical harmonic basis
Hess, C. P., Mukherjee, P., Han, E. T., Xu, D., & Vigneron, D. B. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20931 · Cited by 373
A 64‐channel 3T array coil for accelerated brain MRI
Keil, B. R., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260
Self-citationArray compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 255
Setsompop, K., Wald, L. L., Alagappan, V., Gagoski, B. A., & Elfar Adalsteinsson, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21513 · Cited by 227
Self-citationSotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J., Auerbach, E. J., Yacoub, E. S., Feinberg, D. A., Setsompop, K., Wald, L. L., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24623 · Cited by 192
Self-citationA Model-Based Deconvolution Approach to Solve Fiber Crossing in Diffusion-Weighted MR Imaging
Dell’Acqua, F., Rizzo, G., Scifo, P., Clarke, R. A., Scotti, G., & Fazio, F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.888830 · Cited by 192
de Zwart, J. A., Ledden, P. J., van Gelderen, P., Bodurka, J., Chu, R., & Duyn, J. H. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10678 · Cited by 176
Retinal origin of phosphenes to transcranial alternating current stimulation
Schutter, D. J. L. G., & Hortensius, R. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.038 · Cited by 168
Setsompop, K., Alagappan, V., Gagoski, B. A., Witzel, T., Polimeni, J. R., Potthast, A., Hebrank, F. X., Fontius, U., Schmitt, F., Wald, L. L., et al. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21739 · Cited by 164
Self-citationParallel RF transmission with eight channels at 3 Tesla
Setsompop, K., Wald, L. L., Alagappan, V., Gagoski, B. A., Hebrank, F. X., Fontius, U., Schmitt, F., & Elfar Adalsteinsson, A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21042 · Cited by 163
Self-citationSpatially Regularized Compressed Sensing for High Angular Resolution Diffusion Imaging
Michailovich, O., Yogesh Rathi, A., & Dolui, S. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2142189 · Cited by 150
Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study
Hennig, J., Welz, A. M., Schultz, G., Korvink, J. G., Liu, Z., Speck, O., & Zaitsev, M. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0105-7 · Cited by 145
Magnetophosphenes: a quantitative analysis of thresholds
Lövsund, P., Öberg, P. Å., Nilsson, S. E. G., & Reuter, T. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443387 · Cited by 141
Accelerated diffusion spectrum imaging in the human brain using compressed sensing
Menzel, M. I., Tan, E. T., Khare, K., Sperl, J. I., King, K. F., Tao, X., Hardy, C. J., & Marinelli, L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23064 · Cited by 123
Measurement and correction of transmitter and receiver induced nonuniformities in vivo
Wang, J., Qiu, M., Yang, Q., Smith, M. B. H., & Constable, R. T. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20354 · Cited by 115
Stockmann, J., Ciris, P. A., Galiana, G., Tam, L., & Constable, R. T. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22425 · Cited by 107
Heidemann, R. M., Ivanov, D., Trampel, R., Fasano, F., Meyer, H., Pfeuffer, J., & Turner, R. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24156 · Cited by 90
Simultaneous echo refocusing in EPI
Feinberg, D. A., Reese, T. G., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10227 · Cited by 89
Self-citationSpecific absorption rate studies of the parallel transmission of inner‐volume excitations at 7T
Zelinski, A. C., Angelone, L. M., Goyal, V. K., Bonmassar, G., Elfar Adalsteinsson, A., & Wald, L. L. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21548 · Cited by 84
Self-citationZelinski, A. C., Wald, L. L., Setsompop, K., Alagappan, V., Gagoski, B. A., Goyal, V. K., & Elfar Adalsteinsson, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21585 · Cited by 76
Self-citationMathematical description of q‐space in spherical coordinates: Exact q‐ball imaging
Canales-Rodríguez, E. J., Melie‐García, L., & Iturria‐Medina, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21917 · Cited by 74
Magneto- and electrophosphenes: A comparative study
Lövsund, P., Öberg, P. Å., & Nilsson, S. E. G. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441902 · Cited by 74
The neural signature of phosphene perception
Taylor, P. C. J., Walsh, V., & Martin Eimer, A. (2010) · Human Brain Mapping · doi:10.1002/hbm.20941 · Cited by 73
Schultz, G., Ullmann, P., Lehr, H., Welz, A. M., Hennig, J., & Zaitsev, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22393 · Cited by 70
Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design
Zelinski, A. C., Wald, L. L., Setsompop, K., Goyal, V. K., & Elfar Adalsteinsson, A. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.920605 · Cited by 70
Self-citationMeier, C., Zwanger, M., Feiweier, T., & Porter, D. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21615 · Cited by 69
Accelerated diffusion spectrum imaging with compressed sensing using adaptive dictionaries
Bilgiç, B., Setsompop, K., Cohen‐Adad, J., Yendiki, A., Wald, L. L., & Elfar Adalsteinsson, A. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24505 · Cited by 69
Self-citationMagnetostimulation of Vision: Direct Noninvasive Stimulation of the Retina and the Visual Brain
Marg, E. (1991) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1991.tb02744.x · Cited by 67
Simultaneous multislice acquisition of MR images
Weaver, J. B. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080305 · Cited by 66
Degenerate mode band‐pass birdcage coil for accelerated parallel excitation
Alagappan, V., Nistler, J., Elfar Adalsteinsson, A., Setsompop, K., Fontius, U., Zelinski, A. C., Vester, M., Wiggins, G. C., Hebrank, F. X., Renz, W., et al. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21247 · Cited by 64
Self-citationReese, T. G., Benner, T., Wang, R., Feinberg, D. A., & Wedeen, V. J. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21497 · Cited by 58
Self-citationKoay, C. G., Özarslan, E., & Pierpaoli, C. M. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.03.005 · Cited by 58
Sparse Multi-Shell Diffusion Imaging
Yogesh Rathi, A., Michailovich, O., Setsompop, K., Sylvain Bouix, A., Shenton, M. E., & Westin, C. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_8 · Cited by 56
Self-citationAlford, J. K., Rutt, B. K., Scholl, T. J., Handler, W. B., & Chronik, B. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21933 · Cited by 44
Probabilistic ODF Estimation from Reduced HARDI Data with Sparse Regularization
Tristán‐Vega, A., & Westin, C. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_23 · Cited by 42
Deconvolution in diffusion spectrum imaging
Canales-Rodríguez, E. J., Iturria‐Medina, Y., Alemán‐Gómez, Y., & Melie‐García, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.066 · Cited by 40
WEINTRAUB, M. I., Khoury, A., & Cole, S. P. (2007) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2007.00118.x · Cited by 34
Cohen‐Adad, J., Descoteaux, M., & Wald, L. L. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22535 · Cited by 33
Self-citationReconstruction of MRI data encoded by multiple nonbijective curvilinear magnetic fields
Lin, F., Witzel, T., Schultz, G., Gallichan, D., Kuo, W., Wang, F., Hennig, J., Zaitsev, M., & Belliveau, J. W. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24115 · Cited by 33
Self-citationParametric Dictionary Learning for Modeling EAP and ODF in Diffusion MRI
Merlet, S., Caruyer, E., & Deriche, R. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33454-2_2 · Cited by 30
Development and initial evaluation of 7-T q-ball imaging of the human brain
Mukherjee, P., Hess, C. P., Xu, D., Han, E. T., Kelley, D. A. C., & Vigneron, D. B. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.05.011 · Cited by 26
Spherical wavelet transform for ODF sharpening
Kezele, I., Descoteaux, M., Poupon, C., Poupon, F., & Mangin, J.-F. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.01.002 · Cited by 18
Sparse DSI: Learning DSI Structure for Denoising and Fast Imaging
Gramfort, A., Poupon, C., & Descoteaux, M. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33418-4_36 · Cited by 17
Multiple Q-Shell ODF Reconstruction in Q-Ball Imaging
Aganj, I., Lenglet, C., Sapiro, G., Yacoub, E. S., Uǧurbil, K., & Harel, N. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-04271-3_52 · Cited by 16
Ensemble Average Propagator Reconstruction via Compressed Sensing: Discrete or Continuous Bases ?
Merlet, S., Paquette, M., Rachid Deriche, B., & Descoteaux, M. (2012) · HAL · Cited by 6
Larkman (2001) · doi:10.1002/1522-2586(200102)13:2
Flagged first, then by citations
1 of the 69 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Moeller, 2008, fMRI with 16 fold reduction using multibanded multislice sampling, Proc. of ISMRM, 16, 2366
Cited by
Sorted by citations
Andersson, J., & Sotiropoulos, S. N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,439
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
The Human Connectome Project's neuroimaging approach
Glasser, M. F., Smith, S. M., Marcus, D. S., Andersson, J. L. R., Auerbach, E. J., Behrens, T. E. J., Coalson, T. S., Harms, M. P., Jenkinson, M., Moeller, S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4361 · Cited by 1,090
Functional connectomics from resting-state fMRI
Smith, S. M., Vidaurre, D., Beckmann, C. F., Glasser, M. F., Jenkinson, M., Miller, K. L., Nichols, T. E., Robinson, E. C., Salimi-Khorshidi, G., Woolrich, M. W., et al. (2013) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2013.09.016 · Cited by 952
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 889
Metadata
- Authors
- Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., Cauley, S. F., Tountcheva, V., Matschl, V., Lenz, V. H., Heberlein, K., Potthast, A., Thein, H., Van Horn, J., Toga, A., Schmitt, F., Lehne, D., Rosen, B. R., Wedeen, V., & Wald, L. L.
- Affiliations
- Harvard University (US)
- Siemens Healthineers (Germany) (DE)
- University of California, Los Angeles (US)
- Corresponding author
- Wald, L.L.
- ORCID
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2013-10
- Volume
- 80
- Pages
- 220-233
- ISSN
- 1053-8119 (ISSN-L)
- PMC
- PMC3725309
- OpenAlex
- W1987263024
- Cited by
- 545
- References
- 69
- Citations by year
- 2026: 28 · 2025: 49 · 2024: 41 · 2023: 44 · 2022: 42 · 2021: 61 · 2020: 53 · 2019: 39 · 2018: 39 · 2017: 40 · 2016: 37 · 2015: 51 · 2014: 15 · 2013: 6
- FWCI
- 28.20
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- NeuroImage (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- PolyPublie (École Polytechnique de Montréal) (submittedVersion)
- Funders
- National Institutes of Health, NIH Blueprint Initiative for Neuroscience Research (U01MH093765, P41EB015896, K99/R00EB012107)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- diffusion MRI, Human Connectome Project, compressed sensing, diffusion spectrum imaging, high angular resolution diffusion imaging, signal-to-noise ratio, crossing fibers, diffusion tractography
- MeSH terms
- Animals, Brain, Humans, Image Enhancement, Models, Anatomic, Models, Neurological, Nerve Net, Diffusion Tensor Imaging, Connectome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review