Interpolation of diffusion weighted imaging datasets
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Diffusion weighted imaging (DWI) is used to study white-matter fibre organisation, orientation and structural connectivity by means of fibre reconstruction algorithms and tractography. For clinical settings, limited scan time compromises the possibilities to achieve high image resolution for finer anatomical details and signal-to-noise-ratio for reliable fibre reconstruction. We assessed the potential benefits of interpolating DWI datasets to a higher image resolution before fibre reconstruction using a diffusion tensor model. Simulations of straight and curved crossing tracts smaller than or equal to the voxel size showed that conventional higher-order interpolation methods improved the geometrical representation of white-matter tracts with reduced partial-volume-effect (PVE), except at tract boundaries. Simulations and interpolation of ex-vivo monkey brain DWI datasets revealed that conventional interpolation methods fail to disentangle fine anatomical details if PVE is too pronounced in the original data. As for validation we used ex-vivo DWI datasets acquired at various image resolutions as well as Nissl-stained sections. Increasing the image resolution by a factor of eight yielded finer geometrical resolution and more anatomical details in complex regions such as tract boundaries and cortical layers, which are normally only visualized at higher image resolutions. Similar results were found with typical clinical human DWI dataset. However, a possible bias in quantitative values imposed by the interpolation method used should be considered. The results indicate that conventional interpolation methods can be successfully applied to DWI datasets for mining anatomical details that are normally seen only at higher resolutions, which will aid in tractography and microstructural mapping of tissue compartments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 2×
“Geometric distortions related to susceptibility artefacts wereminimised in the DWIs with the application of a voxel displacement map (VDM) estimated from the two acquired reversed phase encoded b = 0 s/mm2 images (Andersson et al., 2003; Smith et al., 2004).”
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 3×
“The original lower resolution DWI data were interpolated to various higher image resolutions, reconstructed using the diffusion tensor (DT) model (Basser et al., 1994) and compared with the high resolution reference data. iii) We performed classical histology on the same regions investigated with…”
InfluentialAndersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Perlin, K. (1985) · ACM SIGGRAPH Computer Graphics · doi:10.1145/325165.325247 · Cited by 2,525
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296 · cited 1×
“Indeed, such image resolution is too low for today's clinical scanners, but promising new multiplexing techniques have recently been presented allowing clinical scanners to efficiently achieve higher image resolutions while preserving scan time (Feinberg et al., 2010).”
Log-Euclidean metrics for fast and simple calculus on diffusion tensors
Arsigny, V., Fillard, P., Pennec, X., & Ayache, N. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20965 · Cited by 1,113
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Self-citation
Cited by
Accelerated microstructure imaging via Convex Optimization (AMICO) from diffusion MRI data
Daducci, A., Canales-Rodríguez, E. J., Zhang, H., Dyrby, T. B., Alexander, D. C., & Thiran, J.-P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.026 · Cited by 593
Self-citationSuper‐resolution musculoskeletal MRI using deep learning
Chaudhari, A. S., Fang, Z., Kogan, F., Wood, J., Stevens, K. J., Gibbons, E. K., Lee, J. H., Gold, G. E., & Hargreaves, B. A. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27178 · Cited by 406
“16,17 Besides interpolation, another primary method of MRI super-resolution imaging entails using image sparsity with only single images required as inputs.”
MethodDonahue, C. J., Sotiropoulos, S. N., Jbabdi, S., Hernandez-Fernandez, M., Behrens, T. E., Dyrby, T. B., Coalson, T., Kennedy, H., Knoblauch, K., Van Essen, D. C., et al. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.0493-16.2016 · Cited by 380
Self-citationBuilding connectomes using diffusion MRI: why, how and but
Sotiropoulos, S. N., & Zalesky, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3752 · Cited by 290
Cetin Karayumak, S., Bouix, S., Ning, L., James, A., Crow, T., Shenton, M., Kubicki, M., & Rathi, Y. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.073 · Cited by 164
Validation of tractography: Comparison with manganese tracing
Knösche, T. R., Anwander, A., Liptrot, M., & Dyrby, T. B. (2015) · Human Brain Mapping · doi:10.1002/hbm.22902 · Cited by 127
Self-citationSotiropoulos, S. N., Hernández-Fernández, M., Vu, A. T., Andersson, J. L., Moeller, S., Yacoub, E., Lenglet, C., Ugurbil, K., Behrens, T. E. J., & Jbabdi, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.04.014 · Cited by 110
“Future studies can improve on the already highly advanced HCP data by taking into account the results obtained in this study.”
BackgroundMultimodal Hippocampal Subfield Grading For Alzheimer’s Disease Classification
Hett, K., Ta, V.-T., Catheline, G., Tourdias, T., Manjón, J. V., Coupé, P., Initiative, A. D. N., Weiner, M. W., Aisen, P., Petersen, R., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49970-9 · Cited by 49
Basile, G. A., Quartu, M., Bertino, S., Serra, M. P., Trucas, M., Boi, M., Demontis, R., Bramanti, A., Anastasi, G. P., Milardi, D., et al. (2022) · Brain Structure and Function · doi:10.1007/s00429-022-02561-3 · Cited by 12
Metadata
- Authors
- Dyrby, T. B., Lundell, H., Burke, M. W., Reislev, N. L., Paulson, O. B., Ptito, M., & Siebner, H. R.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 103
- Pages
- 202-213
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2037701101
- Cited by
- 135
- References
- 9
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.