Mapping mean axon diameter and axonal volume fraction by MRI using temporal diffusion spectroscopy
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Mapping mean axon diameter and intra-axonal volume fraction may have significant clinical potential because nerve conduction velocity is directly dependent on axon diameter, and several neurodegenerative diseases affect axons of specific sizes and alter axon counts. Diffusion-weighted MRI methods based on the pulsed gradient spin echo (PGSE) sequence have been reported to be able to assess axon diameter and volume fraction non-invasively. However, due to the relatively long diffusion times used, e.g. > 20 ms, the sensitivity to small axons (diameter < 2 µm) is low, and the derived mean axon diameter has been reported to be overestimated. In the current study, oscillating gradient spin echo (OGSE) diffusion sequences with variable frequency gradients were used to assess rat spinal white matter tracts with relatively short effective diffusion times (1 – 5 ms). In contrast to previous PGSE-based methods, the extra-axonal diffusion cannot be modeled as hindered (Gaussian) diffusion when short diffusion times are used. Appropriate frequency-dependent rates are therefore incorporated into our analysis and validated by histology-based computer simulation of water diffusion. OGSE data were analyzed to derive mean axon diameters and intra-axonal volume fractions of rat spinal white matter tracts (mean axon diameter ~ 1.27 – 5.54 µm). The estimated values were in good agreement with histology, including the small axon diameters (< 2.5 µm). This study establishes a framework for quantification of nerve morphology using the OGSE method with high sensitivity to small axons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Free water elimination and mapping from diffusion MRI
Pasternak, O., Sochen, N., Gur, Y., Intrator, N., & Assaf, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22055 · Cited by 1,092
A white matter disorder in dementia of the Alzheimer type: A pathoanatomical study
Brun, A., & Englund, E. (1986) · Annals of Neurology · doi:10.1002/ana.410190306 · Cited by 1,014
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 9×
“The CHARMED model assumes that the AxDs obey a Gamma distribution (Assaf et al., 2008),”
MethodResultInfluentialOrientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683 · cited 6×
“These assumptions have been used in previous diffusion studies in fitting AxD, and reasonable results were obtained (Alexander et al., 2010; Assaf et al., 2008; Barazany et al., 2009; Ong and Wehrli, 2010).”
BackgroundMethodInfluentialPushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545 · cited 1×
“…have been developed that are significantly stronger than normal gradients, such as the Connectome coil with strength up to 300mT/m for humanheads (Setsompop et al., 2013) and local planar gradients with order-of-magnitude greater strength (1000 mT/m) for a limited field-of-view (~16 cm) (Aksel…”
BackgroundAssaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 2×
“However, it is also possible to include the isotropic diffusion from glial cells (Stanisz et al., 1997) and free diffusion, such as in CSF (Barazany et al.”
BackgroundAldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305 · cited 1×
“The samples were then washed in phosphate-buffered saline solution for at least 3 days prior to MRI study to wash out fixatives and restore T2 (Shepherd et al., 2009).”
MethodOscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
Does, M. D., Parsons, E. C., & Gore, J. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10385 · Cited by 246 · cited 2×
“…been successfully implemented to measure the surface-to-volume ratio of porous media (Parsons et al., 2006), and to characterize cerebral ischemia (Does et al., 2003), intra-cellular microstructural variations (Colvin et al., 2011a; Xu et al., 2009a, 2011a) and tumor response to treatment (Colvin…”
BackgroundSelf-citationProbing mouse brain microstructure using oscillating gradient diffusion MRI
Aggarwal, M., Jones, M. V., Calabresi, P. A., Mori, S., & Zhang, J. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22981 · Cited by 117 · cited 3×
“…found to be dependent on the gradient frequency (diffusion time) in afixedmonkey brain (Xu et al., 2010),whichwas later confirmed in a series of studies in fixed mouse brain (Aggarwal et al., 2012), live rat brain (Kershaw et al., 2013), and human brain (Baron and Beaulieu, 2014; Van et al., 2014).”
BackgroundMethod
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
In vivo observation and biophysical interpretation of time-dependent diffusion in human white matter
Fieremans, E., Burcaw, L. M., Lee, H.-H., Lemberskiy, G., Veraart, J., & Novikov, D. S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.018 · Cited by 181
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Advanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Searching for the neurite density with diffusion MRI: challenges for biophysical modeling
Lampinen, B., Szczepankiewicz, F., Novén, M., van Westen, D., Hansson, O., Englund, E., Mårtensson, J., Westin, C., & Nilsson, M. (2019) · Human Brain Mapping · doi:10.1002/hbm.24542 · Cited by 123
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Can increased spatial resolution solve the crossing fiber problem for diffusion MRI?
Schilling, K., Gao, Y., Janve, V., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3787 · Cited by 102
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Hansson, O., Westin, C., & Nilsson, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28216 · Cited by 86
Microstructural imaging in the spinal cord and validation strategies
Cohen-Adad, J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.009 · Cited by 50
“quantifying the diameter of small axons (Kakkar et al., 2018; Xu et al., 2014) or for characterizing tumors and ischemic tissue (Colvin et al.”
Lampinen, B., Szczepankiewicz, F., Lätt, J., Knutsson, L., Mårtensson, J., Björkman-Burtscher, I. M., van Westen, D., Sundgren, P. C., Ståhlberg, F., & Nilsson, M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120338 · Cited by 38
Metadata
- Authors
- Xu, J., Li, H., Harkins, K. D., Jiang, X., Xie, J., Kang, H., Does, M. D., & Gore, J. C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 103
- Pages
- 10-19
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2085530397
- Cited by
- 130
- References
- 10
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.