One-pot synthesis of carboxymethyl-dextran coated iron oxide nanoparticles (CION) for preclinical fMRI and MRA applications
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Superparamagnetic iron-oxide nanoparticles are robust contrast agents for magnetic resonance imaging (MRI) used for sensitive structural and functional mapping of the cerebral blood volume (CBV) when administered intravenously. To date, many CBV-MRI studies are conducted with Feraheme, manufactured for the clinical treatment of iron-deficiency. Unfortunately, Feraheme is currently not available outside the United States due to commercial and regulatory constraints, making CBV-MRI methods either inaccessible or very costly to achieve. To address this barrier, we developed a simple, one-pot recipe to synthesize Carboxymethyl-dextran coated Iron Oxide Nanoparticles, namely, “CION”, suitable for preclinical CBV-MRI applications. Here we disseminate a step-by-step instruction of our one-pot synthesis protocol, which allows CION to be produced in laboratories with minimal cost. We also characterized different CION-conjugations by manipulating polymer to metal stoichiometric ratio in terms of their size, surface chemistry, and chemical composition, and shifts in MR relaxivity and pharmacokinetics. We performed several proof-of-concept experiments in vivo, demonstrating the utility of CION for functional and structural MRI applications, including hypercapnic CO2 challenge, visual stimulation, targeted optogenetic stimulation, and microangiography. We also present evidence that CION can serve as a cross-modality research platform by showing concurrent in vivo optical and MRI measurement of CBV using fluorescent-labeled CION. The simplicity and cost-effectiveness of our one-pot synthesis method should allow researchers to reproduce CION and tailor the relaxivity and pharmacokinetics according to their imaging needs. It is our hope that this work makes CBV-MRI more openly available and affordable for a variety of research applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
The Effect of Nanoparticle Size on In Vivo Pharmacokinetics and Cellular Interaction
Hoshyar, N., Gray, S., Han, H., & Bao, G. (2016) · Nanomedicine · doi:10.2217/nnm.16.5 · Cited by 1,990
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935 · cited 2×
“Blood-oxygenation-level-dependent functional MRI (BOLD-fMRI) is among the most commonly used noninvasive imaging techniques for functional brain mapping (Bandettini et al., 1992; Kim and Ogawa, 2012; Kwong et al., 1992; Logothetis, 2008; Ogawa et al., 1990; Ogawa et al., 1992; Uğurbil, 2012).”
MethodFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Tassa, C., Shaw, S. Y., & Weissleder, R. (2011) · Accounts of Chemical Research · doi:10.1021/ar200084x · Cited by 653
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
Klohs, J., Baltes, C., Princz-Kranz, F., Ratering, D., Nitsch, R. M., Knuesel, I., & Rudin, M. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.5626-11.2012 · Cited by 73
Cited by
Madani, M., Hosny, S., Alshangiti, D. M., Nady, N., Alkhursani, S. A., Alkhaldi, H., Al-Gahtany, S. A., Ghobashy, M. M., & Gaber, G. A. (2022) · Nanotechnology Reviews · doi:10.1515/ntrev-2022-0034 · Cited by 230
“[27] created a one-pot synthesis for carboxymethyl-Dex coated (carboxymethyl cellulose [CMC]) and iron oxide (Fe3O4) NPs, called “CION”, that may be used for functionalmapping and sensitive structural of the cerebral blood volume (CBV) using magnetic resonance imaging (MRI).”
MethodDextran Formulations as Effective Delivery Systems of Therapeutic Agents
Petrovici, A. R., Pinteala, M., & Simionescu, N. (2023) · Molecules · doi:10.3390/molecules28031086 · Cited by 130
Vasić, K., Knez, Ž., & Leitgeb, M. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15080227 · Cited by 76
Menon, V., Cerri, D., Lee, B., Yuan, R., Lee, S.-H., & Shih, Y.-Y. I. (2023) · Nature Communications · doi:10.1038/s41467-023-36616-8 · Cited by 53
Self-citationChao, T.-H. H., Lee, B., Hsu, L.-M., Cerri, D. H., Zhang, W.-T., Wang, T.-W. W., Ryali, S., Menon, V., & Shih, Y.-Y. I. (2023) · Science Advances · doi:10.1126/sciadv.ade5732 · Cited by 49
Self-citation
Metadata
- Authors
- Das, M., Oyarzabal, E. A., Chen, L., Lee, S.-H., Shah, N., Gerlach, G., Zhang, W., Chao, T.-H. H., Berge, N. V. D., Liu, C., Donley, C., Montgomery, S. A., & Shih, Y.-Y. I.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 238
- Pages
- 118213
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W3172058584
- Cited by
- 27
- References
- 10
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One-pot synthesis of carboxymethyl-dextran coated iron oxide nanoparticles (CION) for preclinical fMRI and MRA applications. https://app.cochat.ai/papers/10.1016/j.neuroimage.2021.118213
- The paper
- Das, M., Oyarzabal, E. A., Chen, L., Lee, S.-H., Shah, N., Gerlach, G., Zhang, W., Chao, T.-H. H., Berge, N. V. D., Liu, C., Donley, C., Montgomery, S. A., & Shih, Y.-Y. I. (2021). One-pot synthesis of carboxymethyl-dextran coated iron oxide nanoparticles (CION) for preclinical fMRI and MRA applications. NeuroImage. https://doi.org/10.1016/j.neuroimage.2021.118213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.