Triaxial detection of the neuromagnetic field using optically-pumped magnetometry: feasibility and application in children
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Optically-pumped magnetometers (OPMs) are an established alternative to superconducting sensors for magnetoencephalography (MEG), offering significant advantages including flexibility to accommodate any head size, uniform coverage, free movement during scanning, better data quality and lower cost. However, OPM sensor technology remains under development; there is flexibility regarding OPM design and it is not yet clear which variant will prove most effective for MEG. Most OPM-MEG implementations have either used single-axis (equivalent to conventional MEG) or dual-axis magnetic field measurements. Here we demonstrate use of a triaxial OPM formulation, able to characterise the full 3D neuromagnetic field vector. We show that this novel sensor is able to characterise magnetic fields with high accuracy and sensitivity that matches conventional (dual-axis) OPMs. We show practicality via measurement of biomagnetic fields from both the heart and the brain. Using simulations, we demonstrate how triaxial measurement offers improved cortical coverage, especially in infants. Finally, we introduce a new 3D-printed child-friendly OPM-helmet and demonstrate feasibility of triaxial measurement in a five-year-old. In sum, the data presented demonstrate that triaxial OPMs offer a significant improvement over dual-axis variants and are likely to become the sensor of choice for future MEG systems, particularly for deployment in paediatric populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 6×
“For each dipole location, we computed the forward field (i.e. the eld that would be measured at the MEG sensors in response to a unit urrent) using a current dipole model in a single-shell volume conduc- t 2 i s m 𝑁 t t t r a i a o A v a 3 s o e d 4 b i w t i n I a b s s t v a s t r s w a d a o f 3 3 b p M t s or mode…”
MethodInfluentialHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“Conventional MEG systems (Cohen, 1972; Hämäläinen et al., 1993) detect the neuromagnetic field using superconducting quantum interference devices (SQUIDs; Jaklevic et al.”
MethodBloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676 · cited 1×
“Once in this state, the ulk magnetisation interacts with an external field (e.g., the field from he brain) according to the Bloch Equations ( Bloch, 1946 ).”
BackgroundBasic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 4×
“Theory (Sarvas, 1987) suggests that, assuming the head is a spherical homogeneous conductor and the extracranial space is current-free, if we know the radial component of field at all points on the spherical surface of the conductor, this can be used to derive the local magnetic scalar potential.”
MethodInfluentialMoving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 2×
“, 2015) and motion robustness has enabled a number of demonstrations of novel paradigms, from ball games (Boto et al., 2018) to virtual reality (Roberts et al.”
BackgroundSelf-citationNolte, G. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/22/002 · Cited by 1,022 · cited 4×
“…using the Tikhonov method (reglarisation parameter 5 % of the maximum eigenvalue of the unreguarised matrix) and beamformer weights constructed using a forward odel incorporating a dipole in a single-shell conductor ( Nolte, 2003 ), hich was implemented in FieldTrip ( Oostenveld et al., 2011 ).”
MethodInfluentialCohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785 · cited 2×
“Conventional MEG systems (Cohen, 1972; Hämäläinen et al., 1993) detect the neuromagnetic field using superconducting quantum interference devices (SQUIDs; Jaklevic et al.”
MethodGood practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Quantum Interference Effects in Josephson Tunneling
Jaklevic, R. C., Lambe, J., Silver, A. H., & Mercereau, J. E. (1964) · Physical Review Letters · doi:10.1103/physrevlett.12.159 · Cited by 520
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471 · cited 8×
“SQUIDs have high ensitivity, but must be cryogenically cooled, which means that sensors re fixed rigidly in a one-size-fits-all helmet, and a thermally insulatng gap must be maintained between the sensors and the participant. estricted proximity to the subject lowers both signal strength (which eclines with the square…”
BackgroundInfluentialSelf-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296 · cited 1×
“3) Triaxial sensors provide three times more measurements; tangential fields are known to be weaker than radial fields (Iivanainen et al., 2017) and so this does not”
BackgroundMulti-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285 · cited 8×
“The use of OPMs for MEG measurement is now well established (Borna et al., 2020; Hill et al., 2020; Iivanainen et al., 2019; Kamada et al., 2015) and motion robustness has enabled a number of demonstrations of novel paradigms, from ball games (Boto et al.”
BackgroundMethodInfluentialSelf-citationHolmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
Self-citationHuman motor cortical beta bursts relate to movement planning and response errors
Little, S., Bonaiuto, J., Barnes, G., & Bestmann, S. (2019) · PLOS Biology · doi:10.1371/journal.pbio.3000479 · Cited by 244 · cited 1×
“In recent years, the “classical” view that beta oscillations represent ongoing rhythmic activity has been challenged, by a theory suggesting that beta dynamics can be explained by the occurrence of short punctate bursts of activity whose frequency content intersects with the canonical beta range (Little et al., 2019;…”
BackgroundDetection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances
Dupont-Roc, J., Haroche, S., & Cohen-Tannoudji, C. (1969) · Physics Letters A · doi:10.1016/0375-9601(69)90480-0 · Cited by 182
A tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180 · cited 1×
“Flexibility of sensor placement has facilitated recordings from infants (Hill et al., 2019), and brain regions that are traditionally difficult to access (Tierney et al.”
BackgroundSelf-citationFully integrated, standalone zero field optically pumped magnetometer for biomagnetism
Shah, V., Osborne, J., Orton, J., & Alem, O. (2018) · Steep Dispersion Engineering and Opto-Atomic Precision Metrology XI · doi:10.1117/12.2299197 · Cited by 173 · cited 2×
“Further, newly available commercial PMs are approximately the size and weight of a Lego-brick ( Boto et al., 019 ; Osborne et al., 2018 ).”
BackgroundSelf-citationHolmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163
Self-citationNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system
Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., Hill, R. M., Leggett, J., Rhodes, N., & Bowtell, R. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118025 · Cited by 151 · cited 10×
“Previous work ( Brookes et al., 2021 ; Nurminen et al., 2013 ) has uggested that triaxial measurement offers improved differentiation be- ween fields originating in the brain, and fields generated by sources of xternal interference.”
BackgroundMethodInfluentialSelf-citationCohen-Tannoudji, C., Dupont-Roc, J., Haroche, S., & Laloë, F. (1970) · Revue de Physique Appliquée · doi:10.1051/rphysap:019700050109500 · Cited by 143 · cited 4×
“solution to the Bloch equations shows that the polarisation of atoms in the beam path is given by (Cohen-Tannoudji et al., 1970)”
BackgroundInfluentialWearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136 · cited 2×
“Further, newly available commercial PMs are approximately the size and weight of a Lego-brick ( Boto et al., 019 ; Osborne et al., 2018 ).”
BackgroundSelf-citationMeasuring functional connectivity with wearable MEG
Boto, E., Hill, R. M., Rea, M., Holmes, N., Seedat, Z. A., Leggett, J., Shah, V., Osborne, J., Bowtell, R., & Brookes, M. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117815 · Cited by 132 · cited 3×
“, 2020) enables whole-brain assessment, which is critical in applications like functional connectivity (Boto et al., 2021).”
BackgroundInfluentialSelf-citationTowards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
Self-citationBeauchamp, M. S., Beurlot, M. R., Fava, E., Nath, A. R., Parikh, N. A., Saad, Z. S., Bortfeld, H., & Oghalai, J. S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024981 · Cited by 125 · cited 1×
“The average distance from the scalp to the brain is around 15 mm in an adult, but can be as low as 5 mm (in some brain regions) in a 2-year-old (Beauchamp et al., 2011; Davis, 2021).”
BackgroundPrecision magnetic field modelling and control for wearable magnetoencephalography
Rea, M., Holmes, N., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Woolger, D., Dawson, E., Shah, V., Osborne, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118401 · Cited by 118 · cited 2×
“In OPM-MEG, an additional source of artefact comes from movement (Rea et al., 2021; Seymour et al., 2021).”
BackgroundSelf-citationThe role of transient spectral ‘bursts’ in functional connectivity: A magnetoencephalography study
Seedat, Z. A., Quinn, A. J., Vidaurre, D., Liuzzi, L., Gascoyne, L. E., Hunt, B. A. E., O’Neill, G. C., Pakenham, D. O., Mullinger, K. J., Morris, P. G., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116537 · Cited by 103 · cited 1×
“In recent years, the “classical” view that beta oscillations represent ongoing rhythmic activity has been challenged, by a theory suggesting that beta dynamics can be explained by the occurrence of short punctate bursts of activity whose frequency content intersects with the canonical beta range (Little et al., 2019;…”
BackgroundSelf-citationUsing OPMs to measure neural activity in standing, mobile participants
Seymour, R. A., Alexander, N., Mellor, S., O'Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118604 · Cited by 102 · cited 1×
“In OPM-MEG, an additional source of artefact comes from movement (Rea et al., 2021; Seymour et al., 2021).”
BackgroundPotential of on‐scalp MEG: Robust detection of human visual gamma‐band responses
Iivanainen, J., Zetter, R., & Parkkonen, L. (2020) · Human Brain Mapping · doi:10.1002/hbm.24795 · Cited by 99 · cited 1×
“The use of OPMs for MEG measurement is now well established (Borna et al., 2020; Hill et al., 2020; Iivanainen et al., 2019; Kamada et al., 2015) and motion robustness has enabled a number of demonstrations of novel paradigms, from ball games (Boto et al.”
Mouth magnetoencephalography: A unique perspective on the human hippocampus
Tierney, T. M., Levy, A. D., Barry, D. N., Meyer, S. S., Shigihara, Y., Everatt, M., Mellor, S., López, J. D., Bestmann, S., Holmes, N., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117443 · Cited by 91 · cited 1×
“, 2019), and brain regions that are traditionally difficult to access (Tierney et al., 2021), whilst expanded coverage (Hill et al.”
BackgroundSelf-citationKamada, K., Sato, D., Ito, Y., Natsukawa, H., Okano, K., Mizutani, N., & Kobayashi, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.026601 · Cited by 74 · cited 1×
“The use of OPMs for MEG measurement is now well established (Borna et al., 2020; Hill et al., 2020; Iivanainen et al., 2019; Kamada et al., 2015) and motion robustness has enabled a number of demonstrations of novel paradigms, from ball games (Boto et al.”
Improving MEG Performance With Additional Tangential Sensors
Nurminen, J., Taulu, S., Nenonen, J., Helle, L., Simola, J., & Ahonen, A. I. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2260541 · Cited by 50 · cited 3×
“Indeed, there is good evidence (Brookes et al., 2021; Nurminen et al., 2013) that the additional information gained by measurement of the field vector enables better differentiation of magnetic field patterns from neural sources and external (to the head) interference, thus improving rejection of signals of no interes…”
BackgroundLongitudinal Study of White Matter Development and Outcomes in Children Born Very Preterm
Young, J. M., Morgan, B. R., Whyte, H. E. A., Lee, W., Smith, M. L., Raybaud, C., Shroff, M. M., Sled, J. G., & Taylor, M. J. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhw221 · Cited by 50 · cited 2×
“The templates provided n average head geometry for a 2-year-old, a 4-year-old, and an adult Young et al., 2017 ).”
BackgroundPragmatic spatial sampling for wearable MEG arrays
Tierney, T. M., Mellor, S., O’Neill, G. C., Holmes, N., Boto, E., Roberts, G., Hill, R. M., Leggett, J., Bowtell, R., Brookes, M. J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-77589-8 · Cited by 48 · cited 2×
“Any pragmatic OPM-MEG system involves a finite number of sensors (currently around 50 (Tierney et al., 2020)) and there will always be gaps between sensors.”
BackgroundSelf-citationDavis, N. J. (2020) · European Journal of Neuroscience · doi:10.1111/ejn.14957 · Cited by 32
Reconstruction of quasi-radial dipolar activity using three-component magnetic field measurements
Haueisen, J., Fleissig, K., Strohmeier, D., Elsarnagawy, T., Huonker, R., Liehr, M., & Witte, O. W. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.12.020 · Cited by 23 · cited 8×
“Previous work has seen construction of a complete triaxial sensor array based on SQUIDs (Haueisen et al., 2012).”
BackgroundInfluential
Cited by
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
Self-citationA 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Self-citationHolmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Self-citationNugent, A. C., Benitez Andonegui, A., Holroyd, T., & Robinson, S. E. (2022) · Neuroimage: Reports · doi:10.1016/j.ynirp.2022.100093 · Cited by 41
Metadata
- Authors
- Boto, E., Shah, V., Hill, R. M., Rhodes, N., Osborne, J., Doyle, C., Holmes, N., Rea, M., Leggett, J., Bowtell, R., & Brookes, M. J.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 252
- Pages
- 119027
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W4213330922
- Cited by
- 187
- References
- 37
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.