CoChat

Combining viscoelasticity, diffusivity and volume of the hippocampus for the diagnosis of Alzheimer's disease based on magnetic resonance imaging

Open access
Gerischer, Lea M., Fehlner, Andreas, Köbe, Theresa, Prehn, Kristin, Antonenko, Daria, Grittner, Ulrike, Braun, Jürgen, Sack, Ingolf, Flöel, Agnes · 2018 · NeuroImage: Clinical
Cited by 99

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Dementia due to Alzheimer's Disease (AD) is a neurodegenerative disease for which treatment strategies at an early stage are of great clinical importance. So far, there is still a lack of non-invasive diagnostic tools to sensitively detect AD in early stages and to predict individual disease progression. Magnetic resonance elastography (MRE) of the brain may be a promising novel tool. In this proof-of-concept study, we investigated whether multifrequency-MRE (MMRE) can detect differences in hippocampal stiffness between patients with clinical diagnosis of dementia due to AD and healthy controls (HC). Further, we analyzed if the combination of three MRI-derived parameters, i.e., hippocampal stiffness, hippocampal volume and mean diffusivity (MD), improves diagnostic accuracy. Diagnostic criteria for probable dementia due to AD were in line with the NINCDS-ADRDA criteria and were verified through history-taking (patient and informant), neuropsychological testing, routine blood results and routine MRI to exclude other medical causes of a cognitive decline. 21 AD patients and 21 HC (median age 75 years) underwent MMRE and structural MRI, from which hippocampal volume and MD were calculated. From the MMRE-images maps of the magnitude | G* | and phase angle φ of the complex shear modulus were reconstructed using multifrequency inversion. Median values of | G* | and φ were extracted within three regions of interest (hippocampus, thalamus and whole brain white matter). To test the predictive value of the main outcome parameters, we performed receiver operating characteristic (ROC) curve analyses. Hippocampal stiffness (| G* |) and viscosity ( φ ) were significantly lower in the patient group (both p < 0.001). ROC curve analyses showed an area under the curve (AUC) for | G* | of 0.81 [95%CI 0.68–0.94]; with sensitivity 86%, specificity 67% for cutoff at | G* | = 980 Pa) and for φ an AUC of 0.79 [95%CI 0.66–0.93]. In comparison, the AUC of MD and hippocampal volume were 0.83 [95%CI 0.71–0.95] and 0.86 [95%CI 0.74–0.97], respectively. A combined ROC curve of | G* |, MD and hippocampal volume yielded a significantly improved AUC of 0.90 [95%CI 0.81–0.99]. In conclusion, we demonstrated reduced hippocampal stiffness and reduced hippocampal viscosity, as determined by MMRE, in patients with clinical diagnosis of dementia of the AD type. Diagnostic sensitivity was further improved by the combination with two other MRI-based hippocampal parameters. These findings motivate further investigation whether MMRE can detect decreased brain stiffness already in pre-dementia stages, and whether these changes predict cognitive decline.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nicl.2017.12.023

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 99

Metadata

Authors
Gerischer, L. M., Fehlner, A., Köbe, T., Prehn, K., Antonenko, D., Grittner, U., Braun, J., Sack, I., & Flöel, A.
Venue
NeuroImage: Clinical
Publisher
Elsevier BV
Published
2018
Volume
18
Pages
485-493
ISSN
2213-1582 (ISSN-L)
OpenAlex
W2779230221
Cited by
99
References
19
FWCI
4.18
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.