The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Five-year safety and performance results from the argus II retinal prosthesis system clinical trial.
Open accessAbstract
PURPOSE: The Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP. DESIGN: Prospective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II. PARTICIPANTS: Thirty participants in 10 centers in the United States and Europe. METHODS: The worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. MAIN OUTCOME MEASURES: The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks. RESULTS: Twenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks. CONCLUSIONS: The 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At present, retinal prostheses are the most successful approach in this field, and several retinal devices have already been approved for patients with retinal dystrophies (Da Cruz et al., 2016; Stingl et al., 2017).”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Da Cruz et al., 2016
In the citing paper
“At present, retinal prostheses are the most successful approach in this field, and several retinal devices have already been approved for patients with retinal dystrophies (Da Cruz et al., 2016; Stingl et al., 2017).”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Da Cruz et al., 2016
In the citing paper
“several research groups are focusing their efforts on the development of new approaches for artificial vision based on electric stimulation of the retina”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Da Cruz et al., 2016
In the citing paper
“A multicentre clinical trial of Argus II in patients with end-stage retinitis pigmentosa showed that the device enables basic visual tasks, such as grating visual acuity, high contrast object localisation and detection of direction of motion.”
From Correcting visual loss by genetics and prosthetics (2020) · cites this paper as da Cruz 2016
In the citing paper
“The durability of the device generally exceeded 5 years and the best reported grating visual acuity is around 1.8 logMAR equivalent (6/379 Snellen) [da Cruz 2016; Schaffrath 2019].”
From Correcting visual loss by genetics and prosthetics (2020) · cites this paper as da Cruz 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Self-citationSubretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289
Self-citationLong-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind
Ho, A. C., Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Handa, J. T., Barale, P. O., Sahel, J., Stanga, P. E., Hafezi, F., et al. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.04.032 · Cited by 262
Self-citationDorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177
Self-citationAdvances in gene therapy technologies to treat retinitis pigmentosa
Petrs‐Silva, H., & Linden, R. (2013) · Clinical ophthalmology · doi:10.2147/opth.s38041 · Cited by 81
Geruschat, D. R., Richards, T. P., Arditi, A., Cruz, L., Dagnelie, G., Dorn, J. D., Duncan, J. L., Ho, A. C., Olmos de koo, L. C., Sahel, J., et al. (2016) · Clinical and Experimental Optometry · doi:10.1111/cxo.12359 · Cited by 77
Self-citationFLORA™: phase I development of a functional vision assessment for prosthetic vision users
Geruschat, D. R., Flax, M., Tanna, N., Bianchi, M., Fisher, A., Goldschmidt, M., Fisher, L., Dagnelie, G., Deremeik, J., Smith, A., et al. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12242 · Cited by 75
Self-citationSafety evaluation of “retina implant alpha IMS”—a prospective clinical trial
Kitiratschky, V. B. D., Štingl, K., Wilhelm, B., Peters, T. M., Besch, D., Sachs, H. G., Gekeler, F., Bartz‐Schmidt, K. U., & Zrenner, E. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2797-x · Cited by 55
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 358
Walsh, A. C., Salem, M. E., Oliver, Z. T., & Clark-Sutton, K. (2017) · The Journal of Technology Transfer · doi:10.1007/s10961-017-9610-z · Cited by 5
Çelik, M. E., & Karagoz, I. (2017) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-017-2918-z · Cited by 5
Characterization of an Electronic Corneal Prosthesis System
Shim, S. Y., Gong, S., Fan, V. H., Rosenblatt, M. I., Al-Qahtani, A. F., Sun, M. G., Zhou, Q., Kanu, L. N., Vieira, I. V., & Yu, C. Q. (2019) · Current Eye Research · doi:10.1080/02713683.2019.1708957 · Cited by 5
Abbott, C. J., Baglin, E. K., Kolic, M., McGuinness, M. B., Titchener, S. A., Young, K. A., Yeoh, J., Luu, C. D., Ayton, L. N., Petoe, M. A., et al. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.9.4 · Cited by 5
Koo, B., & Weiland, J. D. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.4.19 · Cited by 5
Proceedings of the 16th Python in Science Conference
(2017) · doi:10.25080/shinma-7f4c6e7-000 · Cited by 6
Retinal prosthesis: a comprehensive review
Menia, N. K., & Venkatesh, P. (2025) · Expert Review of Ophthalmology · doi:10.1080/17469899.2025.2474064 · Cited by 4
Nazari, H. K., Falabella, P., Yue, L., Weiland, J. D., & Humayun, M. S. (2017) · Journal of VitreoRetinal Diseases · doi:10.1177/2474126417702067 · Cited by 4
Self-citationAre long stimulus pulse durations the answer to improving spatial resolution in retinal prostheses?
Petoe, M. A., & Shivdasani, M. N. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.11.24 · Cited by 4
Retinal Prostheses: The Argus System
Lin, T., Yue, L., & Humayun, M. S. (2017) · Technology & Innovation · doi:10.21300/19.3.2018.605 · Cited by 4
Self-citationActive photonic sensing for super-resolved reading performance in simulated prosthetic vision
Abraham, C., Farah, N., Gerbi-Zarfati, L., Harpaz, Y., Zalvesky, Z., & Mandel, Y. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.001081 · Cited by 4
Esquenazi, R., Meier, K., Beyeler, M., Boynton, G. M., & Fine, I. (2021) · Journal of Vision · doi:10.1167/jov.21.13.10 · Cited by 6
Nakanishi, Y., Sasagawa, K., Siwadamrongpong, R., Shodo, K., Terasawa, Y., Takehara, H., Haruta, M., Tashiro, H., & Ohta, J. (2023) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/acb77d · Cited by 4
Word recognition: re-thinking prosthetic vision evaluation
Han, S., Qiu, C., Lee, K. R., Jung, J., & Peli, E. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac663 · Cited by 4
Hsu, P., Chen, P.-Y., Chung, Y.-S., Lin, T.-C., Hwang, D., Chen, S., & Kao, C.-L. (2019) · Journal of the Chinese Medical Association · doi:10.1097/jcma.0000000000000091 · Cited by 4
Lozano, A., Suárez, J. S., Soto‐Sánchez, C., Garrigós, J., Martínez, J. J., Vicente, J. M. F., & Fernández-Jover, E. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-19591-5_12 · Cited by 4
Psychosocial assessment of potential retinal prosthesis trial participants
Bentley, S. A., O’Hare, F., Murphy, G. C., Finger, R. P., Luu, C. D., Keeffe, J. E., Abbott, C. J., Guymer, R. H., & Ayton, L. N. (2019) · Clinical and Experimental Optometry · doi:10.1111/cxo.12889 · Cited by 6
Retinal Prosthesis System for Advanced Retinitis Pigmentosa: A Health Technology Assessment Update.
(2017) · Europe PMC (PubMed Central) · Cited by 4
Stiles, N. R. B., Patel, V. R., & Weiland, J. D. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/519850 · Cited by 4
Building and Sustaining Open-Source Medical Device Projects
Baldwin, A., Elyahoodayan, S., Gunalan, P. K., Pikov, V., & Meng, E. F. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3563102 · Cited by 5
Epiretinal vs. subretinal implant in surgical treatment of retinitis pigmentosa – a review
Pavlova, P., Boneva, J., & Shandurkov, I. (2019) · Bulgarian Review of Ophthalmology · doi:10.14748/bro.v63i1.5814 · Cited by 3
Developing clinical grade flexible implantable electronics
Liu, Y., Balsamo, D., & Degenaar, P. A. (2022) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aca779 · Cited by 4
Current Management Options for Patients with Retinitis Pigmentosa
Thenappan, A. A. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2651-1_32 · Cited by 3
FDA’s role in expediting innovation of bioelectronic implants for vision restoration
Sandrian, M. G., Ng, E., Nguyen, T., & Eydelman, M. B. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd8f1 · Cited by 3
Polymer Matrix Nanocomposites as Photoacoustic Transmitters for Epiretinal Prosthetics
Spicer, J. B., Kang, J., Patterson, A. L., & Boctor, E. M. (2023) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano58406.2023.10231283 · Cited by 3
Assisting Visually Impaired Subjects Using Large Language Models: A Comprehensive Evaluation
Holiel, H. A., Fawzi, S. A., & Al‐Atabany, W. (2024) · Novel Intelligent and Leading Emerging Sciences Conference (NILES) · doi:10.1109/niles63360.2024.10753262 · Cited by 3
Vertically integrated photo junction-field-effect transistor pixels for retinal prosthesis
Damle, S., Liu, Y.-H., Arya, S., Oesch, N. W., & Lo, Y. (2019) · Biomedical Optics Express · doi:10.1364/boe.11.000055 · Cited by 3
Photorezeptortransplantation in die degenerative Netzhaut
Borsch, O., Santos‐Ferreira, T., & Ader, M. (2017) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/s-0043-104421 · Cited by 3
Patelli, F., Colombo, L., Aly, M. O. M., & Rossetti, L. M. (2018) · Retinal Cases & Brief Reports · doi:10.1097/icb.0000000000000816 · Cited by 3
Тахчиди, Х. П., Kachalina, G. F., Тахчиди, Н. Х., Маноян, Р. А., & Глизница, П. В. (2019) · Bulletin of Russian State Medical University · doi:10.24075/brsmu.2019.042 · Cited by 3
EPIRETINAL FIBROSIS REMOVAL IN AN ARGUS II–IMPLANTED EYE
Patelli, F., Falleni, M., Colombo, L., Martinelli, C., Tosi, D., Bulfamante, G., & Rossetti, L. M. (2020) · Retina · doi:10.1097/iae.0000000000002780 · Cited by 3
Using Neuralink by Humans: A Process Which Brings Humanity Closer to the Future
Luckiewicz, A. (2021) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-72254-8_25 · Cited by 3
Yamashita, K., Sundaram, P., Uchida, T., Matsuo, T., & Wong, W. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf892 · Cited by 3
Toward the Miracle of Retinal Reanimation
Gelder, R. N. V. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.08.021 · Cited by 3
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Perceptual learning of prosthetic vision using video game training
Esquenazi, R., Meier, K., Beyeler, M., Wright, D., Boynton, G. M., & Fine, I. (2025) · Journal of Vision · doi:10.1167/jov.25.12.12 · Cited by 2
Nagai, T., Homma, K., Kawamata, Y., Yoshihara, M., Kawakami, E., & Baba, T. (2026) · npj Digital Medicine · doi:10.1038/s41746-025-02311-9 · Cited by 2
Zhang, B., You, X., Liu, Y. P., Xu, J., & Xu, S. (2026) · Sensors · doi:10.3390/s26020576 · Cited by 2
Rassia, K. E. K., Liapi, L., & Pezaris, J. S. (2026) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2026.101494 · Cited by 2
Narala, R., Humayun, M. S., & Ameri, H. (2019) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/23258160-20190129-09 · Cited by 2
Self-citationINTRAOPERATIVE OPTICAL COHERENCE TOMOGRAPHY AND ENDOSCOPY-GUIDED EXPLANTATION OF ARGUS II DEVICE
Cai, C. X., & Vajzovic, L. M. (2020) · Retinal Cases & Brief Reports · doi:10.1097/icb.0000000000000994 · Cited by 2
Yoon, Y. H., Yue, L., & Humayun, M. S. (2020) · Springer eBooks · doi:10.1007/978-981-15-7644-7_34 · Cited by 2
Self-citationRestauration de la vision: Science-fiction ou réalité ?
Picaud, S. A., & Sahel, J. (2020) · médecine/sciences · doi:10.1051/medsci/2020213 · Cited by 2
Self-citationSidhu, S., Persad, P. J., Lam, B. L., Zann, K. L., & Gregori, N. Z. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12165283 · Cited by 2
Morimoto, T., Fujikado, T., Kanda, H., Miyoshi, T., Endo, T., Nishida, K., Kishima, H., Saito, T. R., Ito, K., Ozawa, M., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.3.13 · Cited by 2
Detecting Progression of Retinitis Pigmentosa Using the Binomial Pointwise Linear Regression Method
Asano, S., Oishi, A., Asaoka, R., Fujino, Y., Murata, H., Azuma, K., Miyata, M., Obata, R., & Inoue, T. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.13.15 · Cited by 2
Carignan, M., Courchesne, M., Cantin, S., Moore, V., & Poncet, F. (2022) · Journal of Visual Impairment & Blindness · doi:10.1177/0145482x221092020 · Cited by 2
Clarifier l’impact fonctionnel des rétines artificielles
Roux, S., Gascon, P., Pham, P., Matonti, F., & Chavane, F. (2017) · médecine/sciences · doi:10.1051/medsci/20173304007 · Cited by 2
Positive Visual Phenomena Following Implantation of the Argus II Retinal Prosthesis
Sadaka, A., Iqbal, C., Nazari, H. K., Berry, S. E., Wykoff, C. C., Humayun, M. S., & Lee, A. G. (2017) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/23258160-20171130-11 · Cited by 2
Self-citationBae, S. H., Jeong, J., Kim, S. J., Chung, H., & Seo, J.-M. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.4.17 · Cited by 2
Corneal Allograft Treatment for Conjunctival Erosion Caused by Electronic Retinal Implant
Rommel, F., & Grisanti, S. (2020) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.0051 · Cited by 2
A scalable data transmission scheme for implantable optogenetic visual prostheses
Hou, Z., Al‐Atabany, W., Farag, R., Vuong, Q. C., Mokhov, A., & Degenaar, P. A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abaf2e · Cited by 2
Gebrehiwot, A. N., Kato, T., & Nakazawa, K. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249996 · Cited by 2
Flourence, M., Merlini, F., Leffel, A., Fossati, M., Meddouri, S., Carbone, V., Benninghofen, M., Studer, F., Dollfus, H., Gaucher, D., et al. (2023) · Journal of Visual Impairment & Blindness · doi:10.1177/0145482x231205581 · Cited by 2
Geruschat, D. R., Rankin, M., & Dorn, J. D. (2017) · Journal of Visual Impairment & Blindness · doi:10.1177/0145482x1711100611 · Cited by 2
Self-citationNishida, K., Sakaguchi, H., Kamei, M., Saito, T., Fujikado, T., & Nishida, K. (2019) · Journal of Artificial Organs · doi:10.1007/s10047-019-01095-6 · Cited by 2
Lam, B. L., & Gregori, N. Z. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.1057 · Cited by 2
Benetatos, A., Melanitis, N., & Nikita, K. S. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630963 · Cited by 3
Cellular integration with a subretinal honeycomb-shaped prosthesisPreprint
Bhuckory, M. B., Chen, Z., Wang, B.-Y., Shin, A., Huang, T., Galambos, L., Vounotrypidis, E., Mathieson, K., Kamins, T. I., & Palanker, D. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.12.15.520681 · Cited by 2
Navigating the regulatory pathway for an innovative bionic vision system
Chevrie, K. (2020) · Advanced Biomedical and Clinical Diagnostic and Surgical Guidance Systems XVIII · doi:10.1117/12.2560182 · Cited by 1
Innovative Technologien fur optimiertes kunstliches Sehen
Walter, P. (2022) · Laryngo-Rhino-Otologie · doi:10.1055/a-1671-1825 · Cited by 1
Patterson, A. L., Song, H., Kang, J., Boctor, E. M., & Spicer, J. B. (2024) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano61778.2024.10628547 · Cited by 1
Hallum, L. E., & Cloherty, S. L. (2024) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad811e · Cited by 1
Xie, H., Ye, Z., & Chan, L. L. H. (2025) · Scientific Reports · doi:10.1038/s41598-025-08657-0 · Cited by 2
Kim, J., & Seo, J.-M. (2025) · Biomedical Engineering Letters · doi:10.1007/s13534-025-00513-4 · Cited by 1
Alqahtani, H. B., Votruba, M., & Regini, J. W. (2025) · Therapeutic Advances in Ophthalmology · doi:10.1177/25158414251385884 · Cited by 1
Lee, C.-Y., Lai, T., Chiang, C.-Y., Wang, Y.-C., Lin, S.-Y., Chiang, Y.-J., Yang, Y.-T., Yang, C., & Fan, L.-S. (2026) · Translational Vision Science & Technology · doi:10.1167/tvst.15.5.20 · Cited by 1
Optogenetics for therapeutic use in the brain, eye, and ear
Ng, B., MacLaren, R. E., & Cehajic‐Kapetanovic, J. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-22212-2.00018-5 · Cited by 1
Restoring vision and touch with cortical microstimulation
Valle, G., Oswalt, D. N., Gaunt, R. A., Roelfsema, P. R., Greenspon, C. M., & Fernandez, E. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00449-z · Cited by 1
Retinal Prostheses: Patient Selection and Screening
Gregori, N. Z., & de Koo, L. C. O. (2017) · Essentials in ophthalmology/Essentials ophthalmology · doi:10.1007/978-3-319-67260-1_3 · Cited by 1
Toward an optoelectronic-based visual prosthesis: control unit design and validation
Ayed, H. B., Ali, M., Saha, S., Masmoudi, M., & Sawan, M. (2018) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-018-1294-2 · Cited by 1
Induced Pluripotent Stem Cell-Based Cell Therapy of the Retina
Takagi, S. T., Mandai, M., Hirami, Y., Kurimoto, Y., & Takahashi, M. (2019) · Current human cell research and applications · doi:10.1007/978-981-13-3672-0_8 · Cited by 1
Phthisis Bulbi in a Retinitis Pigmentosa Patient after Argus II Implantation
Woude, L. V., Roohipourmoallai, R., & Khurshid, G. S. (2020) · Case Reports in Ophthalmological Medicine · doi:10.1155/2020/5608058 · Cited by 1
Yamashita, K., Tanaka, T., Matsuo, T., & Uchida, T. (2021) · Biomedical Materials · doi:10.1088/1748-605x/abe809 · Cited by 1
The First Epiretinal Implant for Hereditary Blindness in the Asia-Pacific Region.
Yanagihara, R. T., Yamane, M. L. M., & Kokame, G. T. (2021) · PubMed Central · Cited by 1
Retinal repair in tissue engineering perspectives
Nair, D. S. R., & Thomas, B. B. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824064-9.00022-8 · Cited by 1
Neurostimulators for high-resolution artificial retina: ASIC design challenges and solutions
Jeong, H., Kim, J., Seo, J.-M., & Neviani, A. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/aca262 · Cited by 1
Wireless Bioelectronic Interfaces Electromagnetic Performance and Safety
Kim, H., Dong, Z., & Ho, J. S. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_24 · Cited by 1
Demonstration of multi-point stimulation with AC-driven CMOS chips for retinal prosthesis
Nakanishi, Y., Sriitsaranusorn, W., Hattori, T., Tso, K.-C., Shodo, K., Terasawa, Y., Sunaga, Y., Takehara, H., Haruta, M., Tashiro, H., et al. (2024) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ad1fad · Cited by 1
New frontiers in retinal transplantation
Sorrentino, F. S., Terlizzi, P. D., Rosa, F. D., Salati, C., Spadea, L., Gagliano, C., Musa, M., & Zeppieri, M. (2024) · World Journal of Transplantation · doi:10.5500/wjt.v14.i4.97690 · Cited by 1
Hinrichs, S., Placidet, L., Duret, A., Authié, C., Arleo, A., & Ghezzi, D. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8b6f · Cited by 1
Transplantation Immunology: Retinal Cell-Based Therapy
Sandhu, H. S., Adeniran, J. F., & Kaplan, H. J. (2019) · Stem cell biology and regenerative medicine · doi:10.1007/978-3-030-05222-5_8 · Cited by 1
Role of Multimedia in Medicine: Study of Visual Prosthesis
Sarosh, P., Parah, S. A., & Sarosh, R. (2019) · Springer eBooks · doi:10.1007/978-3-030-15887-3_27 · Cited by 1
Therapeutic approaches and development of genomic diagnostic tools for Usher syndrome
García, C. F. (2020) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/137034 · Cited by 1
Fine, I., & Boynton, G. M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.03.18.532424 · Cited by 1
Editorial – Application of Nanoscopic Quantum Systems in Retinal Restoration
Mohammadi, H., & Rafii‐Tabar, H. (2024) · Journal of Ophthalmic and Vision Research · doi:10.18502/jovr.v19i1.15415 · Cited by 1
Bunel, M. (2017) · theses.fr (ABES) · doi:10.70675/2c39f34dz974dz470bzb45azca176b38a75e · Cited by 1
Neuromodulation for Treatment of Dry Eye
Franke, M., Loudin, J., & Ackermann, D. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00102-9
Moshiri, A., & Yazdanyar, A. (2018) · Current practices in ophthalmology · doi:10.1007/978-981-10-8545-1_5
Surgical Instrumentation and Devices
Ho, J., Nguyen, B. J., & Chao, D. L. (2018) · Current practices in ophthalmology · doi:10.1007/978-981-10-8545-1_9
Tokuda, T., Ohta, J., Tashiro, H., & Terasawa, Y. (2018) · Wiley eBooks · doi:10.1002/047134608x.w8370
Current Advances in the Design of Retinal and Cortical Visual Prostheses
Bareket, L., Barriga‐Rivera, A., Rosenfeld, J. V., Lovell, N. H., & Suaning, G. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00005-2
Cortical visual prosthesis: a detailed large-scale simulation studyPreprint
Antolík, J., Sabatier, Q., Galle, C., Frégnac, Y., & Benosman, R. B. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/610378
Leber congenital amaurosis in a young female
Connelly, A. M., & Grosel, J. M. (2019) · JAAPA · doi:10.1097/01.jaa.0000580540.26228.6b
“Eye genetics at the fork in the road” 2017 Franceschetti Lecture, Leeds UK
Mackey, D. A. (2020) · Ophthalmic Genetics · doi:10.1080/13816810.2020.1755988
Korobelnik, J., & Delyfer, M. (2020) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2020.06.003
Antiulcer and Blood-Boosting Activities of Feeds Supplemented with Trametes versicolor from Nigeria
Jonathan, S. G., Omeonu, F., Salami, A. T., Chikwem, J. O., Gbadamosi, I. T., Asemoloye, M. D., & Aina, D. A. (2020) · Scholars Academic Journal of Biosciences · doi:10.36347/sajb.2020.v08i09.005
Yamashita, K., Tanaka, T., Matsuo, T., & Uchida, T. (2021) · Polymer Journal · doi:10.1038/s41428-021-00468-0
Artificial Vision and Retinal Prosthesis
Mura, M., & Schatz, P. (2021) · Springer eBooks · doi:10.1007/978-981-33-4168-5_41
Treatment Of Hereditary Retinal Dystrophies. Perspectives And Social Aspects
Мермеклиева, Е. (2020) · Bulgarian Review of Ophthalmology · doi:10.14748/bro.v64i2.7146
Metadata
- Authors
- da Cruz, L., Dorn, J. D., Humayun, M. S., Dagnelie, G., Handa, J., Barale, P.-O., Sahel, J.-A., Stanga, P. E., Hafezi, F., Safran, A. B., Salzmann, J., Santos, A., Birch, D., Spencer, R., Cideciyan, A. V., de Juan, E., Duncan, J. L., Eliott, D., Fawzi, A., Olmos de Koo, L. C., Ho, A. C., Brown, G., Haller, J., Regillo, C., Del Priore, L. V., Arditi, A., & Greenberg, R. J.
- Affiliations
- Second Sight Medical Products (US)
- University of Southern California (US)
- Johns Hopkins University (US)
- Centre hospitalier national d'ophtalmologie des Quinze-Vingts (FR)
- Institut de la Vision (FR)
- Manchester Academic Health Science Centre (GB)
- Centro de Retina Médica y Quirúrgica (MX)
- Retina Foundation of the Southwest (US)
- Texas Retina Associates (United States) (US)
- University of Pennsylvania (US)
- University of California, San Francisco (US)
- Northwestern University (US)
- Wills Eye Hospital (US)
- Lighthouse Guild (US)
- Corresponding author
- Dorn, Jessy D.
- ORCID
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2016-10
- Volume
- 123
- Issue
- 10
- Pages
- 2248-2254
- ISSN
- 0161-6420 (ISSN-L)
- PMC
- PMC5035591
- OpenAlex
- W2476154117
- Cited by
- 359
- References
- 12
- Citations by year
- 2026: 30 · 2025: 23 · 2024: 20 · 2023: 33 · 2022: 33 · 2021: 45 · 2020: 47 · 2019: 48 · 2018: 41 · 2017: 35 · 2016: 3
- FWCI
- 23.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Ophthalmology (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (publishedVersion, other-oa)
- PubMed Central (acceptedVersion)
- Institutional Repository of Tecnológico de Monterrey (Tecnológico de Monterrey) (submittedVersion, other-oa)
- UCL Discovery (University College London) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by-nc-nd)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, other-oa)
- Funders
- National Eye Institute (R01EY012893, RC3EY020778)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- Argus II, retinal prosthesis, retinitis pigmentosa, outer retinal degeneration, long-term safety, visual function, functional vision, electrode arrays, blind patients, adverse events
- MeSH terms
- Adult, Aged, Blindness, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Prosthesis Design, Retina, Retinitis Pigmentosa, Time Factors, Visual Acuity, Treatment Outcome, Persons with Visual Disabilities, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review