The DISCOVER Study 3-Year Results
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective To report the three-year assessment of feasibility and utility of microscope integrated intraoperative optical coherence tomography (iOCT) during ophthalmic surgery. Design Prospective, consecutive, case series Participants Adult subjects undergoing incisional ophthalmic surgery with intraoperative OCT imaging that consented to be enrolled in the Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery (DISCOVER) study. Methods The DISCOVER study is a single-site, multi-surgeon, IRB-approved investigational device prospective study. Participants included patients undergoing anterior or posterior segment surgery and underwent iOCT imaging with one of three prototype microscope-integrated iOCT systems (i.e., Zeiss Rescan 700, Leica EnFocus, Cole Eye iOCT system). Clinical characteristics were documented, iOCT was directed by the operating surgeon at predetermined surgical time points, and each surgeon completed a questionnaire after surgery to evaluate the utility of iOCT during surgery. Outcomes 1. Feasibility of iOCT based ability to obtain an OCT image during surgery. 2. Utility of iOCT based on surgeon reporting during surgery Results A total of 837 eyes (244 anterior segment and 593 posterior segment cases) were enrolled in the DISCOVER study. IOCT demonstrated feasibility with successful image acquisition in 820 (98.0%, CI: 96.8–98.8%) eyes. In 106 (43.4%, CI: 37.1–49.9) anterior segment cases, the surgeons indicated that the iOCT information impacted their surgical decision-making and altered the procedure. In posterior segment procedures, surgeons reported iOCT provided altered surgical decision-making during the procedure in 173 (29.2%, CI: 25.5–33.0%) cases. Conclusions The DISCOVER iOCT study demonstrates both generalized feasibility and utility based on the surgeon-reported impact on surgical decision-making. This large-scale study confirms similar findings of other studies on the potential value and impact of iOCT on ophthalmic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Autologous Induced Stem-Cell–Derived Retinal Cells for Macular Degeneration
Mandai, M., Watanabe, A., Kurimoto, Y., Hirami, Y., Morinaga, C., Daimon, T., Fujihara, M., Akimaru, H., Sakai, N., Shibata, Y., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1608368 · Cited by 1,509
Gregori, N. Z., Lam, B. L., & Davis, J. L. (2019) · Retina · doi:10.1097/iae.0000000000001646 · Cited by 54
Cited by
Intraoperative optical coherence tomography: past, present, and future
Ehlers, J. P. (2016) · Eye · doi:10.1038/eye.2015.255 · Cited by 77
Self-citationVasconcelos, H. M., Lujan, B. J., Pennesi, M. E., Yang, P., & Lauer, A. K. (2020) · International Journal of Retina and Vitreous · doi:10.1186/s40942-020-00216-1 · Cited by 39
Hints for gentle submacular injection in non-human primates based on intraoperative OCT guidance
Tan, G. S. W., Liu, Z., Ilmarinen, T., Barathi, V. A., Chee, C. K., Lingam, G., Su, X., & Stanzel, B. V. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.1.10 · Cited by 21
Metadata
- Authors
- Ehlers, J. P., Modi, Y. S., Pecen, P. E., Goshe, J., Dupps, W. J., Rachitskaya, A., Sharma, S., Yuan, A., Singh, R., Kaiser, P. K., Reese, J. L., Calabrise, C., Watts, A., & Srivastava, S. K.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 125
- Issue
- 7
- Pages
- 1014-1027
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2786458964
- Cited by
- 146
- References
- 2
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The DISCOVER Study 3-Year Results. https://app.cochat.ai/papers/10.1016/j.ophtha.2017.12.037
- The paper
- Ehlers, J. P., Modi, Y. S., Pecen, P. E., Goshe, J., Dupps, W. J., Rachitskaya, A., Sharma, S., Yuan, A., Singh, R., Kaiser, P. K., Reese, J. L., Calabrise, C., Watts, A., & Srivastava, S. K. (2018). The DISCOVER Study 3-Year Results. Ophthalmology. https://doi.org/10.1016/j.ophtha.2017.12.037
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.