The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Overview of artificial intelligence-based applications in radiotherapy: Recommendations for implementation and quality assurance
Open accessAbstract
Artificial Intelligence (AI) is currently being introduced into different domains, including medicine. Specifically in radiation oncology, machine learning models allow automation and optimization of the workflow. A lack of knowledge and interpretation of these AI models can hold back wide-spread and full deployment into clinical practice. To facilitate the integration of AI models in the radiotherapy workflow, generally applicable recommendations on implementation and quality assurance (QA) of AI models are presented. For commonly used applications in radiotherapy such as auto-segmentation, automated treatment planning and synthetic computed tomography (sCT) the basic concepts are discussed in depth. Emphasis is put on the commissioning, implementation and case-specific and routine QA of AI models needed for a methodical introduction in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Arrieta, A. B., Díaz-Rodríguez, N., Del Ser, J., Bennetot, A., Tabik, S., Barbado, A., García, S., Gil-López, S., Molina, D., Benjamins, R., et al. (2019) · arXiv · doi:10.48550/arxiv.1910.10045 · Cited by 11,321
Barredo Arrieta, A., Díaz-Rodríguez, N., Del Ser, J., Bennetot, A., Tabik, S., Barbado, A., Garcia, S., Gil-Lopez, S., Molina, D., Benjamins, R., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.12.012 · Cited by 10,423
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0697 · Cited by 3,267
Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool
Taha, A. A., & Hanbury, A. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0068-x · Cited by 2,920
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Continuous Improvement as an Ideal in Health Care
Berwick, D. M. (1989) · New England Journal of Medicine · doi:10.1056/nejm198901053200110 · Cited by 1,716
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
On Defining Artificial Intelligence
Wang, P. (2019) · Journal of Artificial General Intelligence · doi:10.2478/jagi-2019-0002 · Cited by 740
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Deep learning in medical image registration: a survey
Haskins, G., Kruger, U., & Yan, P. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01060-x · Cited by 704
Huq, M. S., Fraass, B. A., Dunscombe, P., Gibbons, J. P., Ibbott, G. S., Mundt, A. J., Mutic, S., Palta, J. R., Rath, F., Thomadsen, B., et al. (2016) · Medical Physics · doi:10.1118/1.4947547 · Cited by 607
Deep MR to CT Synthesis Using Unpaired Data
Wolterink, J. M., Dinkla, A. M., Savenije, M. H. F., Seevinck, P. R., van den Berg, C. A. T., & Išgum, I. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-68127-6_2 · Cited by 593
Self-citationImage Reconstruction is a New Frontier of Machine Learning
Wang, G., Ye, J. C., Mueller, K., & Fessler, J. A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2833635 · Cited by 525
Segmentation of organs‐at‐risks in head and neck CT images using convolutional neural networks
Ibragimov, B., & Xing, L. (2017) · Medical Physics · doi:10.1002/mp.12045 · Cited by 502
Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2624938 · Cited by 455
Confidence calibration and predictive uncertainty estimation for deep medical image segmentation
Mehrtash, A., Wells, W. M., Tempany, C. M., Abolmaesumi, P., & Kapur, T. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3006437 · Cited by 428
Deep Learning MR Imaging–based Attenuation Correction for PET/MR Imaging
Liu, F., Jang, H., Kijowski, R., Bradshaw, T., & McMillan, A. B. (2018) · Radiology · doi:10.1148/radiol.2017170700 · Cited by 412
Cardenas, C. E., Yang, J., Anderson, B. M., Court, L. E., & Brock, K. B. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.001 · Cited by 407
Predicting dose‐volume histograms for organs‐at‐risk in IMRT planning
Appenzoller, L. M., Michalski, J. M., Thorstad, W. L., Mutic, S., & Moore, K. L. (2012) · Medical Physics · doi:10.1118/1.4761864 · Cited by 382
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer
Lustberg, T., van Soest, J., Gooding, M., Peressutti, D., Aljabar, P., van der Stoep, J., van Elmpt, W., & Dekker, A. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.11.012 · Cited by 368
Self-citationFan, J., Wang, J., Chen, Z., Hu, C., Zhang, Z., & Hu, W. (2019) · Medical Physics · doi:10.1002/mp.13271 · Cited by 353
Nguyen, D., Long, T., Jia, X., Lu, W., Gu, X., Iqbal, Z., & Jiang, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-37741-x · Cited by 352
Big Data and machine learning in radiation oncology: State of the art and future prospects
Bibault, J.-E., Giraud, P., & Burgun, A. (2016) · Cancer Letters · doi:10.1016/j.canlet.2016.05.033 · Cited by 346
Survey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
Men, K., Dai, J., & Li, Y. (2017) · Medical Physics · doi:10.1002/mp.12602 · Cited by 298
MRI‐only based synthetic CT generation using dense cycle consistent generative adversarial networks
Lei, Y., Harms, J., Wang, T., Liu, Y., Shu, H., Jani, A. B., Curran, W. J., Mao, H., Liu, T., & Yang, X. (2019) · Medical Physics · doi:10.1002/mp.13617 · Cited by 297
Yuan, L., Ge, Y., Lee, W. R., Yin, F. F., Kirkpatrick, J. P., & Wu, Q. J. (2012) · Medical Physics · doi:10.1118/1.4757927 · Cited by 285
Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer
Tol, J. P., Delaney, A. R., Dahele, M., Slotman, B. J., & Verbakel, W. F. A. R. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.11.014 · Cited by 279
Automation in intensity modulated radiotherapy treatment planning—a review of recent innovations
Hussein, M., Heijmen, B. J. M., Verellen, D., & Nisbet, A. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20180270 · Cited by 272
Self-citationGe, Y., & Wu, Q. J. (2019) · Medical Physics · doi:10.1002/mp.13526 · Cited by 259
Artificial intelligence in radiation oncology: A specialty-wide disruptive transformation?
Thompson, R. F., Valdes, G., Fuller, C. D., Carpenter, C. M., Morin, O., Aneja, S., Lindsay, W. D., Aerts, H. J. W. L., Agrimson, B., Deville, C., et al. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.05.030 · Cited by 258
Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
Self-citationArtificial Intelligence in Radiotherapy Treatment Planning: Present and Future
Wang, C., Zhu, X., Hong, J. C., & Zheng, D. (2019) · Technology in Cancer Research & Treatment · doi:10.1177/1533033819873922 · Cited by 251
Improving automatic delineation for head and neck organs at risk by Deep Learning Contouring
van Dijk, L. V., Van den Bosch, L., Aljabar, P., Peressutti, D., Both, S., J.H.M. Steenbakkers, R., Langendijk, J. A., Gooding, M. J., & Brouwer, C. L. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.09.022 · Cited by 239
Self-citationMRI-only treatment planning: benefits and challenges
Owrangi, A. M., Greer, P. B., & Glide-Hurst, C. K. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aaaca4 · Cited by 236
Nikolov, S., Blackwell, S., Zverovitch, A., Mendes, R. L., Livne, M., Fauw, J. D., Patel, Y., Meyer, C., Askham, H., Romera‐Paredes, B., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.04430 · Cited by 235
Hsu, S.-H., Cao, Y., Huang, K., Feng, M., & Balter, J. M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8419 · Cited by 233
Veiga, C., McClelland, J., Moinuddin, S., Lourenço, A., Ricketts, K., Annkah, J., Modat, M., Ourselin, S., D'Souza, D., & Royle, G. (2014) · Medical Physics · doi:10.1118/1.4864240 · Cited by 216
Mayo, C. S., Moran, J. M., Bosch, W., Xiao, Y., McNutt, T., Popple, R., Michalski, J., Feng, M., Marks, L. B., Fuller, C. D., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.12.013 · Cited by 212
3D Variation in delineation of head and neck organs at risk
Brouwer, C. L., Steenbakkers, R. J., van den Heuvel, E., Duppen, J. C., Navran, A., Bijl, H. P., Chouvalova, O., Burlage, F. R., Meertens, H., Langendijk, J. A., et al. (2012) · Radiation Oncology · doi:10.1186/1748-717x-7-32 · Cited by 211
Self-citationCraft, D. L., Hong, T. S., Shih, H. A., & Bortfeld, T. R. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.12.007 · Cited by 207
Vaassen, F., Hazelaar, C., Vaniqui, A., Gooding, M., van der Heyden, B., Canters, R., & van Elmpt, W. (2020) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2019.12.001 · Cited by 204
Self-citationSynthetic CT generation from CBCT images via deep learning
Chen, L., Liang, X., Shen, C., Jiang, S., & Wang, J. (2020) · Medical Physics · doi:10.1002/mp.13978 · Cited by 201
Men, K., Chen, X., Zhang, Y., Zhang, T., Dai, J., Yi, J., & Li, Y. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00315 · Cited by 200
Medical Device Regulation: An Introduction for the Practicing Physician
Maisel, W. H. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-4-200402170-00012 · Cited by 194
A mathematical framework for virtual IMRT QA using machine learning
Valdes, G., Scheuermann, R., Hung, C. Y., Olszanski, A., Bellerive, M., & Solberg, T. D. (2016) · Medical Physics · doi:10.1118/1.4953835 · Cited by 193
Fogliata, A., Belosi, F., Clivio, A., Navarria, P., Nicolini, G., Scorsetti, M., Vanetti, E., & Cozzi, L. (2014) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2014.11.009 · Cited by 190
McIntosh, C., Welch, M., McNiven, A., Jaffray, D. A., & Purdie, T. G. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa71f8 · Cited by 190
An introduction to deep learning in medical physics: advantages, potential, and challenges
Shen, C., Nguyen, D., Zhou, Z., Jiang, S. B., Dong, B., & Jia, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab6f51 · Cited by 185
IMRT QA using machine learning: A multi‐institutional validation
Valdes, G., Chan, M. F., Lim, S. B., Scheuermann, R., Deasy, J. O., & Solberg, T. D. (2017) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12161 · Cited by 164
Kazemifar, S., McGuire, S., Timmerman, R., Wardak, Z., Nguyen, D., Park, Y., Jiang, S., & Owrangi, A. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.026 · Cited by 164
Applications and limitations of machine learning in radiation oncology
Jarrett, D., Stride, E., Vallis, K., & Gooding, M. J. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20190001 · Cited by 164
Deep Learning: A Review for the Radiation Oncologist
Boldrini, L., Bibault, J., Masciocchi, C., Shen, Y., & Bittner, M.-I. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.00977 · Cited by 162
Automated Treatment Planning in Radiation Therapy using Generative Adversarial NetworksPreprint
Mahmood, R., Babier, A., McNiven, A., Diamant, A., & Chan, T. C. Y. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.06489 · Cited by 156
Chang, A. T. Y., Hung, A. W. M., Cheung, F. W. K., Lee, M. C. H., Chan, O. S. H., Philips, H., Cheng, Y.-T., & Ng, W. T. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2016.02.017 · Cited by 153
The Role of Imaging in Radiation Therapy Planning: Past, Present, and Future
Pereira, G. C., Traughber, M. S., & Muzic, R. F. (2014) · BioMed Research International · doi:10.1155/2014/231090 · Cited by 152
Dinkla, A. M., Wolterink, J. M., Maspero, M., Savenije, M. H. F., Verhoeff, J. J. C., Seravalli, E., Išgum, I., Seevinck, P. R., & van den Berg, C. A. T. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.058 · Cited by 151
Self-citationExpert-augmented machine learning
Gennatas, E. D., Friedman, J. H., Ungar, L., Pirracchio, R., Eaton, E., Reichmann, L. G., Interian, Y., Luna, J. M., Simone, C. B., Auerbach, A., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1906831117 · Cited by 148
Benefits of deep learning for delineation of organs at risk in head and neck cancer
van der Veen, J., Willems, S., Deschuymer, S., Robben, D., Crijns, W., Maes, F., & Nuyts, S. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.05.010 · Cited by 146
Self-citationDeep nets vs expert designed features in medical physics: An IMRT QA case study
Interian, Y., Rideout, V. C., Kearney, V. P., Gennatas, E. D., Morin, O., Cheung, J., Solberg, T. D., & Valdés, G. (2018) · Medical Physics · doi:10.1002/mp.12890 · Cited by 143
Li, W., Li, Y., Qin, W., Liang, X., Xu, J., Xiong, J., & Xie, Y. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-19-885 · Cited by 141
Li, J., Wang, L., Zhang, X., Liu, L., Li, J., Chan, M. F., Jing Sui (Beijing Normal University), my correct affiliation is beijing normal university, N. Q. U. O. S. A. T., & Yang, R. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.07.049 · Cited by 138
A deep learning‐based prediction model for gamma evaluation in patient‐specific quality assurance
Tomori, S., Kadoya, N., Takayama, Y., Kajikawa, T., Shima, K., Narazaki, K., & Jingu, K. (2018) · Medical Physics · doi:10.1002/mp.13112 · Cited by 136
Deep Learning-Based Delineation of Head and Neck Organs at Risk: Geometric and Dosimetric Evaluation
van Rooij, W., Dahele, M. R., Brandao, H. R., Delaney, A. R., Slotman, B. J., & Verbakel, W. F. A. R. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.02.040 · Cited by 136
Nyflot, M. J., Thammasorn, P., Wootton, L. S., Ford, E. C., & Chaovalitwongse, W. A. (2018) · Medical Physics · doi:10.1002/mp.13338 · Cited by 135
Kurz, C., Maspero, M., Savenije, M. H. F., Landry, G., Kamp, F., Pinto, M., Li, M., Parodi, K., Belka, C., & van den Berg, C. A. T. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab4d8c · Cited by 131
DeepDose: Towards a fast dose calculation engine for radiation therapy using deep learning
Kontaxis, C., Bol, G. H., Lagendijk, J. J. W., & Raaymakers, B. W. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab7630 · Cited by 129
Machine learning and modeling: Data, validation, communication challenges
Naqa, I. E., Ruan, D., Valdés, G., Dekker, A. L. A. J., McNutt, T., Ge, Y., Wu, Q., Oh, J. H., Thor, M., Smith, W. P., et al. (2018) · Medical Physics · doi:10.1002/mp.12811 · Cited by 128
Machine Learning in Radiation Oncology: Opportunities, Requirements, and Needs
Feng, M. U.-S., Valdés, G., Dixit, N., & Solberg, T. D. (2018) · Frontiers in Oncology · doi:10.3389/fonc.2018.00110 · Cited by 124
Predicting gamma passing rates for portal dosimetry‐based IMRT QA using machine learning
Lam, D., Zhang, X., Li, H., Deshan, Y., Schott, B., Zhao, T., Zhang, W., Mutic, S., & Sun, B. (2019) · Medical Physics · doi:10.1002/mp.13752 · Cited by 116
Clinical implementation of AI technologies will require interpretable AI models
Jia, X., Ren, L., & Cai, J. (2019) · Medical Physics · doi:10.1002/mp.13891 · Cited by 116
Spadea, M. F., Pileggi, G., Zaffino, P., Salome, P., Catana, C., Izquierdo‐Garcia, D., Amato, F., & Seco, J. C. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.06.2535 · Cited by 114
Qi, M., Li, Y., Wu, A., Jia, Q., Li, B., Sun, W., Dai, Z., Lu, X., Zhou, L., Deng, X., et al. (2020) · Medical Physics · doi:10.1002/mp.14075 · Cited by 114
Dinkla, A. M., Florkow, M. C., Maspero, M., Savenije, M. H. F., Zijlstra, F., Doornaert, P., van Stralen, M., Philippens, M. E. P., van den Berg, C. A. T., & Seevinck, P. R. (2019) · Medical Physics · doi:10.1002/mp.13663 · Cited by 108
Self-citationSavenije, M. H. F., Maspero, M., Sikkes, G. G., van Zyp, J. R. N. V. D. V., Kotte, A. N. T. J., Bol, G. H., & van den Berg, C. A. T. (2020) · Radiation Oncology · doi:10.1186/s13014-020-01528-0 · Cited by 107
Automated Radiotherapy Treatment Planning
Moore, K. L. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.003 · Cited by 104
Liu, Y., Lei, Y., Wang, Y., Wang, T., Ren, L., Lin, L., McDonald, M. W., Curran, W. J., Liu, T., Zhou, J., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab25bc · Cited by 99
A machine learning approach to the accurate prediction of multi-leaf collimator positional errors
Carlson, J., Park, J. M., Park, S. Y., Park, J. M., Choi, Y., & Ye, S. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/6/2514 · Cited by 90
Maspero, M., Houweling, A. C., Savenije, M. H. F., van Heijst, T. C. F., Verhoeff, J. J. C., Kotte, A. N. T. J., & van den Berg, C. A. T. (2020) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2020.04.002 · Cited by 90
Gooding, M. J., Smith, A. J., Tariq, M., Aljabar, P., Peressutti, D., van der Stoep, J., Reymen, B., Emans, D., Hattu, D., van Loon, J., et al. (2018) · Medical Physics · doi:10.1002/mp.13200 · Cited by 89
Matsuo, M., Miwa, K., Tanaka, O., Shinoda, J., Nishibori, H., Tsuge, Y., Yano, H., Iwama, T., Hayashi, S., Hoshi, H., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.09.020 · Cited by 83
Liu, Y., Lei, Y., Wang, Y., Shafai‐Erfani, G., Wang, T., Tian, S., Patel, P. R., Jani, A. B., McDonald, M. W., Curran, W. J., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab41af · Cited by 83
Granville, D., Sutherland, J., Bélec, J., & Russa, D. J. L. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab142e · Cited by 81
Radiation Therapy Quality Assurance Tasks and Tools: The Many Roles of Machine Learning
Kalet, A. M., Luk, S. M. H., & Phillips, M. H. (2019) · Medical Physics · doi:10.1002/mp.13445 · Cited by 78
Artificial intelligence will soon change the landscape of medical physics research and practice
Xing, L., Krupinski, E. A., & Cai, J. (2018) · Medical Physics · doi:10.1002/mp.12831 · Cited by 77
Nyholm, T., & Jonsson, J. H. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.005 · Cited by 73
Evaluation of a multi-atlas CT synthesis approach for MRI-only radiotherapy treatment planning
Guerreiro, F., Burgos, N., Dunlop, A., Wong, K.-H., Petkar, I., Nutting, C., Harrington, K. J., Bhide, S. A., Newbold, K. L., Dearnaley, D. P., et al. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.02.017 · Cited by 71
McIntosh, C., Svistoun, I., & Purdie, T. G. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2251421 · Cited by 69
Using Artificial Intelligence to Improve the Quality and Safety of Radiation Therapy
Pillai, M., Adapa, K., Das, S. K., Mazur, L. M., Dooley, J., Marks, L. B., Thompson, R. F., & Chera, B. S. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.06.001 · Cited by 65
Recommendations on how to establish evidence from auto-segmentation software in radiotherapy
Valentini, V., Boldrini, L., Damiani, A., & Muren, L. P. (2014) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2014.09.014 · Cited by 64
Li, Q., & Chan, M. F. (2016) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13215 · Cited by 64
Lee, H., Kim, H., Kwak, J., Kim, Y. S., Lee, S.-W., Cho, S., & Cho, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-52262-x · Cited by 63
Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Court, L. E., Kisling, K. D., McCarroll, R. E., Zhang, L., Yang, J., Simonds, H. M., du Toit, M., Trauernicht, C. J., Burger, H., Parkes, J., et al. (2018) · Journal of Visualized Experiments · doi:10.3791/57411 · Cited by 61
Chan, J. W. S., Kearney, V. P., Haaf, S., Wu, S. Y., Bogdanov, M., Reddick, M., Dixit, N., Sudhyadhom, A., Chen, J., Yom, S. S., et al. (2019) · Medical Physics · doi:10.1002/mp.13495 · Cited by 61
Kimura, Y., Kadoya, N., Tomori, S., Oku, Y., & Jingu, K. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.03.022 · Cited by 59
Chen, H., Tan, J., Dolly, S. R., Kavanaugh, J., Anastasio, M. A., Low, D. A., Li, H. H., Altman, M. B., Gay, H. A., Thorstad, W. L., et al. (2015) · Medical Physics · doi:10.1118/1.4906197 · Cited by 58
Bragman, F., Tanno, R., Eaton-Rosen, Z., Li, W., Hawkes, D. J., Sebastien Ourselin, A., Alexander, D. C., McClelland, J. R., & Cardoso, M. J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-00937-3_1 · Cited by 56
Olberg, S., Zhang, H., Kennedy, W. R., Chun, J., Rodriguez, V. L., Zoberi, I., Thomas, M. A., Kim, J. S., Mutic, S., Green, O. L., et al. (2019) · Medical Physics · doi:10.1002/mp.13716 · Cited by 54
Naqa, I. E., Irrer, J., Ritter, T. A., DeMarco, J. J., Al‐Hallaq, H., Booth, J. T., Kim, G., Alkhatib, A., Popple, R. A., Perez, M., et al. (2019) · Medical Physics · doi:10.1002/mp.13433 · Cited by 53
Kortesniemi, M., Tsapaki, V., Trianni, A., Russo, P., Maas, A. J. J., Källman, H., Brambilla, M., & Damilakis, J. E. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.11.005 · Cited by 47
Bragman, F., Tanno, R., Eaton-Rosen, Z., Li, W., Hawkes, D., Sebastien Ourselin, A., Alexander, D. C., McClelland, Jr., & Cardoso, M. J. (2018) · UCL Discovery (University College London) · Cited by 46
Artificial intelligence will reduce the need for clinical medical physicists
Tang, X., Wang, B., & Rong, Y. (2018) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12244 · Cited by 41
Barkousaraie, A. S., Ogunmolu, O., Jiang, S. B., & Nguyen, D. T. D. (2019) · Medical Physics · doi:10.1002/mp.13986 · Cited by 40
Farjam, R., Tyagi, N., Veeraraghavan, H., Apte, A., Zakian, K. L., Hunt, M. A., & Deasy, J. O. (2017) · Medical Physics · doi:10.1002/mp.12303 · Cited by 38
Rattan, R., Kataria, T., Banerjee, S., Goyal, S., Gupta, D., Pandita, A., Bisht, S. S., Narang, K., & Mishra, S. R. (2019) · BJR|Open · doi:10.1259/bjro.20180031 · Cited by 37
Maspero, M., Tyyger, M., Tijssen, R. H. N., Seevinck, P. R., Intven, M., & van den Berg, C. A. T. (2018) · Physics and Imaging in Radiation Oncology · doi:10.1016/j.phro.2018.09.002 · Cited by 33
Willems, S., Crijns, W., Saint‐Esteven, A. L. G., van der Veen, J., Robben, D., Depuydt, T., Nuyts, S., Haustermans, K. M., & Maes, F. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01201-4_24 · Cited by 30
Self-citationUncertainty Quantification in Deep Learning for Safer Neuroimage Enhancement
Tanno, R., Worrall, D., Kaden, E., Ghosh, A., Grussu, F., Bizzi, A., Sotiropoulos, S. N., Criminisi, A., & Alexander, D. C. (2019) · arXiv · doi:10.48550/arxiv.1907.13418 · Cited by 30
Generating Pareto Optimal Dose Distributions for Radiation Therapy Treatment Planning
Nguyen, D. T. D., Barkousaraie, A. S., Shen, C., Jia, X., & Jiang, S. B. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32226-7_7 · Cited by 30
Wu, B., Zhang, P., Tsirakis, B., Kanchaveli, D., & LoSasso, T. J. (2018) · Medical Physics · doi:10.1002/mp.13363 · Cited by 15
(2018) · Cited by 6
Cited by
Hurkmans, C., Bibault, J.-E., Brock, K. K., van Elmpt, W., Feng, M., David Fuller, C., Jereczek-Fossa, B. A., Korreman, S., Landry, G., Madesta, F., et al. (2024) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2024.110345 · Cited by 110
Hindocha, S., Zucker, K., Jena, R., Banfill, K., Mackay, K., Price, G., Pudney, D., Wang, J., & Taylor, A. (2023) · Clinical Oncology · doi:10.1016/j.clon.2023.01.014 · Cited by 69
Artificial intelligence in radiotherapy
Li, G., Wu, X., & Ma, X. (2022) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2022.08.005 · Cited by 46
Metadata
- Authors
- Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W.
- Venue
- Radiotherapy and Oncology
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 153
- Pages
- 55-66
- ISSN
- 0167-8140 (ISSN-L)
- OpenAlex
- W3085467444
- Cited by
- 321
- References
- 116
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.