Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND Incorrect usage of inhaler devices might have a major influence on the clinical effectiveness of the delivered drug. This issue is poorly addressed in management guidelines. METHODS This article presents the results of a systematic literature review of studies evaluating incorrect use of established dry powder inhalers (DPIs) by patients with asthma or chronic obstructive pulmonary disease (COPD). RESULTS Overall, we found that between 4% and 94% of patients, depending on the type of inhaler and method of assessment, do not use their inhalers correctly. The most common errors made included failure to exhale before actuation, failure to breath-hold after inhalation, incorrect positioning of the inhaler, incorrect rotation sequence, and failure to execute a forceful and deep inhalation. Inefficient DPI technique may lead to insufficient drug delivery and hence to insufficient lung deposition. As many as 25% of patients have never received verbal inhaler technique instruction, and for those that do, the quality and duration of instruction is not adequate and not reinforced by follow-up checks. CONCLUSIONS This review demonstrates that incorrect DPI technique with established DPIs is common among patients with asthma and COPD, and suggests that poor inhalation technique has detrimental consequences for clinical efficacy. Regular assessment and reinforcement of correct inhalation technique are considered by health professionals and caregivers to be an essential component of successful asthma management. Improvement of asthma and COPD management could be achieved by new DPIs that are easy to use correctly and are forgiving of poor inhalation technique, thus ensuring more successful drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Universities and tobacco money: Some universities are accomplices in the tobacco epidemic
Cohen, J. E. (2001) · BMJ · doi:10.1136/bmj.323.7303.1 · Cited by 943
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Self-citationMisuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
Giraud, V., & Roche, N. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00218402 · Cited by 538
Inhaled Corticosteroids for Asthma Therapy
Cochrane, M. G., Bala, M. V., Downs, K. E., Mauskopf, J., & Ben-Joseph, R. H. (2000) · Chest · doi:10.1378/chest.117.2.542 · Cited by 428
Molimard, M., Raherison, C., Lignot, S., Depont, F., Abouelfath, A., & Moore, N. (2003) · Journal of Aerosol Medicine · doi:10.1089/089426803769017613 · Cited by 398
Evolution of dry powder inhaler design, formulation, and performance
NEWMAN, S. P., & BUSSE, W. W. (2002) · Respiratory Medicine · doi:10.1053/rmed.2001.1276 · Cited by 340
Crompton, G. K., Barnes, P. J., Broeders, M., Corrigan, C., Corbetta, L., Dekhuijzen, R., Dubus, J. C., Magnan, A., Massone, F., Sanchis, J., et al. (2006) · Respiratory Medicine · doi:10.1016/j.rmed.2006.01.008 · Cited by 280
Self-citationMultiple inhalers confuse asthma patients
van der Palen, J., Klein, J., van Herwaarden, C., Zielhuis, G., & Seydel, E. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.14510349 · Cited by 219
van Beerendonk, I., Mesters, I., Mudde, A. N., & Tan, T. D. (1998) · Journal of Asthma · doi:10.3109/02770909809068218 · Cited by 211
Errors in Inhalation Technique and Efficiency in Inhaler Use in Asthmatic Children
Pedersen, S., Frost, L., & Arnfred, T. (1986) · Allergy · doi:10.1111/j.1398-9995.1986.tb00287.x · Cited by 200
Cited by
Inhaler mishandling remains common in real life and is associated with reduced disease control
Melani, A. S., Bonavia, M., Cilenti, V., Cinti, C., Lodi, M., Martucci, P., Serra, M., Scichilone, N., Sestini, P., Aliani, M., et al. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.01.005 · Cited by 947
What the pulmonary specialist should know about the new inhalation therapies
Laube, B. L., Janssens, H. M., de Jongh, F. H. C., Devadason, S. G., Dhand, R., Diot, P., Everard, M. L., Horvath, I., Navalesi, P., Voshaar, T., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00166410 · Cited by 806
Self-citationSystematic Review of Errors in Inhaler Use
Sanchis, J., Gich, I., & Pedersen, S. (2016) · CHEST · doi:10.1016/j.chest.2016.03.041 · Cited by 538
Self-citationAerosol drug delivery: developments in device design and clinical use
Dolovich, M. B., & Dhand, R. (2011) · The Lancet · doi:10.1016/s0140-6736(10)60926-9 · Cited by 505
Critical inhaler errors in asthma and COPD: a systematic review of impact on health outcomes
Usmani, O. S., Lavorini, F., Marshall, J., Dunlop, W. C. N., Heron, L., Farrington, E., & Dekhuijzen, R. (2018) · Respiratory Research · doi:10.1186/s12931-017-0710-y · Cited by 402
Self-citationGibson, P. G., McDonald, V. M., & Marks, G. B. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61087-2 · Cited by 394
Inhaler competence in asthma: Common errors, barriers to use and recommended solutions
Price, D., Bosnic-Anticevich, S., Briggs, A., Chrystyn, H., Rand, C., Scheuch, G., & Bousquet, J. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2012.09.017 · Cited by 358
Inhaler Errors in the CRITIKAL Study: Type, Frequency, and Association with Asthma Outcomes
Price, D. B., Román-Rodríguez, M., McQueen, R. B., Bosnic-Anticevich, S., Carter, V., Gruffydd-Jones, K., Haughney, J., Henrichsen, S., Hutton, C., Infantino, A., et al. (2017) · The Journal of Allergy and Clinical Immunology: In Practice · doi:10.1016/j.jaip.2017.01.004 · Cited by 327
Self-citationTechnological and practical challenges of dry powder inhalers and formulations
Hoppentocht, M., Hagedoorn, P., Frijlink, H. W., & de Boer, A. H. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.04.004 · Cited by 303
Validation of the ‘Test of the Adherence to Inhalers’ (TAI) for Asthma and COPD Patients
Plaza, V., Fernández-Rodríguez, C., Melero, C., Cosío, B. G., Entrenas, L. M., de Llano, L. P., Gutiérrez-Pereyra, F., Tarragona, E., Palomino, R., López-Viña, A., et al. (2016) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2015.1212 · Cited by 284
AL-Jahdali, H., Ahmed, A., AL-Harbi, A., Khan, M., Baharoon, S., Bin Salih, S., Halwani, R., & Al-Muhsen, S. (2013) · Allergy, Asthma & Clinical Immunology · doi:10.1186/1710-1492-9-8 · Cited by 278
Rootmensen, G. N., van Keimpema, A. R. J., Jansen, H. M., & de Haan, R. J. (2010) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2009.0785 · Cited by 231
“In the literature, the prevalence of incorrect inhalation shows considerable variability,((3,4)) which may be caused by, among other factors, differences in scoring methods.”
Exacerbation rate, health status and mortality in COPD – a review of potential interventions
Seemungal, T. (2009) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s3385 · Cited by 197
Choosing inhaler devices for people with asthma: Current knowledge and outstanding research needs
Haughney, J., Price, D., Barnes, N. C., Virchow, J. C., Roche, N., & Chrystyn, H. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.04.012 · Cited by 190
“Moreover, regular assessment and reinforcement are needed to maintain handling and inhalation technique.(10) For patients who cannot coordinate actuation and inhalation with an MDI, switching to a breath-actuated MDI may be a solution.”
Inhaled chemotherapy in lung cancer: future concept of nanomedicine
Zarogoulidis, P., Zarogoulidis, K., Domvri, Goldberg, Karamanos, Schmidt, & Chatzaki (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s29997 · Cited by 185
“Failure to use the device properly is a common error and therefore a dose is not delivered promptly.(115) Dry powder inhalers with high resistance provide increased deposition to the lung parenchyma,(113,116) but the clinical significance of this remains to be clarified.”
Retail sales of inhalation devices in European countries: So much for a global policy
Lavorini, F., Corrigan, C. J., Barnes, P. J., Dekhuijzen, P. R. N., Levy, M. L., Pedersen, S., Roche, N., Vincken, W., & Crompton, G. K. (2011) · Respiratory Medicine · doi:10.1016/j.rmed.2011.03.012 · Cited by 171
Self-citationKowatsch, T., Schachner, T., Harperink, S., Barata, F., Dittler, U., Xiao, G., Stanger, C., v Wangenheim, F., Fleisch, E., Oswald, H., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/25060 · Cited by 103
“Another common concern is poor technique during medication inhalation, leading to reduced dispersion of the drug in the lungs, and subsequent decreased asthma stability and lowered clinical effectiveness of the delivered drug [41-44].”
Metadata
- Authors
- Lavorini, F., Magnan, A., Christophe Dubus, J., Voshaar, T., Corbetta, L., Broeders, M., Dekhuijzen, R., Sanchis, J., Viejo, J. L., Barnes, P., Corrigan, C., Levy, M., & Crompton, G. K.
- Venue
- Respiratory Medicine
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 102
- Issue
- 4
- Pages
- 593-604
- ISSN
- 0954-6111 (ISSN-L)
- OpenAlex
- W2068797397
- Cited by
- 609
- References
- 23
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.