Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 501

The DOI matches its Crossref record; 107 of the 107 references it cites were found in a registry or an index.

Comparative analysis of building insulation material properties and performance

Open access
Kumar, Dileep, Alam, Morshed, Zou, Patrick X.W., Sanjayan, Jay G., Memon, Rizwan Ahmed·2020·Renewable and Sustainable Energy Reviews

Abstract

Abstract Building envelope insulation is crucial for an energy-efficient and comfortable indoor environment because the envelope accounts for 50–60% of total heat gain/loss in a building. Previous studies mostly used lifecycle cost as the criteria to select the optimum insulation materials with little or no consideration of embodied energy, emission, and summer overheating potential. This study presents a comparative analysis of building insulation materials properties (thermal, hygroscopic, acoustic, reaction to fire, environmental, and cost) and their performance in different climate zones and proposed an optimization framework. Insulation materials can be primarily categorized as conventional, state-of-the-art and sustainable. State-of-the-art insulation materials have the lowest thermal conductivity value amongst the three insulation types. However, their life cycle cost is higher compared to the other types. Sustainable insulation materials could be useful to delay and minimize indoor peak temperature and reduce overheating risk during the hot summer period. The analysis also showed that building walls with comparatively lower thermal resistance are more cost-effective for the cooling dominated region, but walls with higher thermal resistance are more cost-effective in heating-dominated regions. However, highly insulated and airtight houses may also lead to increased overheating risk and peak cooling demand during a hot summer period. In addition, hygroscopic, acoustic, and fire retardancy properties of insulation materials are critical to control indoor relative humidity in a humid region, to maintain a minimum noise level in a zone, and to reduce fire destruction. Hence, the optimization should include four criteria 1) Energy, 2) Environment, 3) Economic, and 4) Comfort.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.rser.2020.110038

Cites

107 of 107 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 107 references

Cited by

See all 501

Metadata

Authors
Kumar, D., Alam, M., Zou, P. X. W., Sanjayan, J. G., & Memon, R. A.
Venue
Renewable and Sustainable Energy Reviews
Publisher
Elsevier BV
Published
2020-10
Volume
131
Pages
110038
ISSN
1364-0321 (ISSN-L)
OpenAlex
W3042290089
Cited by
501
References
107
FWCI
25.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative analysis of building insulation material properties and performance. https://app.cochat.ai/papers/10.1016/j.rser.2020.110038
The paper
Kumar, D., Alam, M., Zou, P. X. W., Sanjayan, J. G., & Memon, R. A. (2020). Comparative analysis of building insulation material properties and performance. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2020.110038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.