High cell viability microfluidic electroporation in a curved channel
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Placing electrodes with a narrow gap in the microchannel path can also generate a locally intense electric field within the channel [22,25,27,31,33,36].”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [31]
In the citing paper
“Electrolysis can cause bubbling, leading to channel clogging, cell damage, and changes in the pH of the buffer.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [31]
In the citing paper
“However, this type of equipment faces challenges related to electrolysis at the electrodes.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [31]
In the citing paper
“Several strategies have been proposed to mitigate these issues. They include applying a voltage below the redox potential [27], separating the electrode and cell suspension using a gel [22], and separating the flow of the cell suspension from the flow at the electrodes to prevent mixing of cells with lysed buffer [25,31,33].”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [31]
In the citing paper
“The shape of this type of channel can be easily adjusted, and a small amount of sample liquid can be processed when using a narrow and short channel.”
From Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines (2025) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 33
- Gehl, 2003, Electroporation: theory and methods, perspectives for drug delivery, gene therapy and research, Acta Physiol. Scand., 177, 437, 10.1046/j.1365-201X.2003.01093.x · DOI · Paper page
- Hockemeyer, 2009, Efficient targeting of expressed and silent genes in human ESCs and iPSCs using zinc-finger nucleases, Nat. Biotechnol., 27, 851, 10.1038/nbt.1562 · DOI · Paper page
- Dove, 2009, Antibody production branches out, Nat. Methods, 6, 851, 10.1038/nmeth1109-851 · doi:10.1038/nmeth1109-851
- Goodnow, 2010, Control systems and decision making for antibody production, Nat. Immunol., 11, 681, 10.1038/ni.1900 · DOI · Paper page
- Kim, 2007, A multi-channel electroporation microchip for gene transfection in mammalian cells, Biosens. Bioelectron., 22, 3273, 10.1016/j.bios.2007.02.009 · doi:10.1016/j.bios.2007.02.009
- Li, 2015, Electroporation on microchips: the harmful effects of pH changes and scaling down, Sci. Rep., 5, 17817, 10.1038/srep17817 · DOI
- Geng, 2010, Flow-through electroporation based on constant voltage for large-volume transfection of cells, J. Control. Release, 144, 91, 10.1016/j.jconrel.2010.01.030 · DOI · Paper page
- Kim, 2008, A novel electroporation method using a capillary and wire-type electrode, Biosens. Bioelectron., 23, 1353, 10.1016/j.bios.2007.12.009 · doi:10.1016/j.bios.2007.12.009
- Lee, 2015, Continuous medium exchange and optically induced electroporation of cells in an integrated microfluidic system, Microsyst. Nanoeng., 1, 15007, 10.1038/micronano.2015.7 · doi:10.1038/micronano.2015.7
- Zhan, 2009, Electroporation of cells in microfluidic droplets, Anal. Chem., 81, 2027, 10.1021/ac9001172 · DOI
- Kim, 2007, Continuous low-voltage dc electroporation on a microfluidic chip with polyelectrolytic salt bridges, Anal. Chem., 79, 7761, 10.1021/ac071197h · DOI · Paper page
- Wei, 2011, A laminar flow electroporation system for efficient DNA and siRNA delivery, Anal. Chem., 83, 5881, 10.1021/ac200625b · DOI
- Dean, 1927, XVI. Note on the motion of fluid in a curved pipe, London Edinburgh Dublin Philos. Mag. J. Sci., 4, 208, 10.1080/14786440708564324 · DOI · Paper page
- Dean, 1928, LXXII. The stream-line motion of fluid in a curved pipe (Second paper), London Edinburgh Dublin Philos. Mag. J. Sci., 5, 673, 10.1080/14786440408564513 · doi:10.1080/14786440408564513
- Huang, 2015, A Flow-through electroporation device utilizing dean vortex to enhance cell viability, 2015 Transducers – 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers), 650, 10.1109/TRANSDUCERS.2015.7181007 · doi:10.1109/transducers.2015.7181007
- Sudarsan, 2006, Multivortex micromixing, Proc. Natl. Acad. Sci. U. S. A., 103, 7228, 10.1073/pnas.0507976103 · DOI · Paper page
- Bhagat, 2008, Continuous particle separation in spiral microchannels using Dean flows and differential migration, Lab Chip, 8, 1906, 10.1039/b807107a · DOI · Paper page
- Kuntaegowdanahalli, 2009, Inertial microfluidics for continuous particle separation in spiral microchannels, Lab Chip, 9, 2973, 10.1039/b908271a · DOI · Paper page
- Gossett, 2009, Particle focusing mechanisms in curving confined flows, Anal. Chem., 81, 8459, 10.1021/ac901306y · DOI · Paper page
- Lee, 2009, Three-dimensional hydrodynamic focusing with a single sheath flow in a single-layer microfluidic device, Lab Chip, 9, 3155, 10.1039/b910712f · doi:10.1039/b910712f
- Hou, 2013, Isolation and retrieval of circulating tumor cells using centrifugal forces, Sci. Rep., 3, 1259, 10.1038/srep01259 · DOI · Paper page
- Di Carlo, 2007, Continuous inertial focusing, ordering, and separation of particles in microchannels, Proc. Natl. Acad. Sci. U. S. A., 104, 18892, 10.1073/pnas.0704958104 · DOI · Paper page
- Bhagat, 2010, Inertial microfluidics for sheath-less high-throughput flow cytometry, Biomed. Microdevices, 12, 187, 10.1007/s10544-009-9374-9 · doi:10.1007/s10544-009-9374-9
- Wang, 2010, Vortex-assisted DNA delivery, Lab Chip, 10, 2057, 10.1039/c004472e · doi:10.1039/c004472e
- Yun, 2013, Sequential multi-molecule delivery using vortex-assisted electroporation, Lab Chip, 13, 2764, 10.1039/c3lc50196e · DOI · Paper page
- Vickers, 2014, Direct drug cocktail analyses using microscale vortex-assisted electroporation, Anal. Chem., 86, 10099, 10.1021/ac501479g · DOI
- Erdogan, 1967, The effects of curvature and buoyancy on the laminar dispersion of solute in a horizontal tube, J. Fluid Mech., 29, 465, 10.1017/S0022112067000977 · doi:10.1017/s0022112067000977
- Lin, 2001, Electroporation microchips for continuous gene transfection, Sens. Actuators B, 79, 137, 10.1016/S0925-4005(01)00859-0 · doi:10.1016/s0925-4005(01)00859-0
- Yoon, 2009, Size-selective separation of micro beads by utilizing secondary flow in a curved rectangular microchannel, Lab Chip, 9, 87, 10.1039/B809123D · doi:10.1039/b809123d
- Wu, 2012, Separation of leukocytes from blood using spiral channel with trapezoid cross-section, Anal. Chem., 84, 9324, 10.1021/ac302085y · doi:10.1021/ac302085y
- Amini, 2014, Inertial microfluidic physics, Lab Chip, 14, 2739, 10.1039/c4lc00128a · DOI · Paper page
- Canatella, 2001, Quantitative study of electroporation-mediated molecular uptake and cell viability, Biophys. J ., 80, 755, 10.1016/S0006-3495(01)76055-9 · DOI · Paper page
- Wei, 2014, Flow-through cell electroporation microchip integrating dielectrophoretic viable cell sorting, Anal. Chem., 86, 10215, 10.1021/ac502294e · DOI · Paper page
Cited by
Ishii-Teshima, M., Maeda, K., Hanauchi, K., Asechi, E., Setyawan, D., Niki, T., Nakashima, K., Kurita, H., Numano, R., & Shibata, T. (2025) · PLOS One · doi:10.1371/journal.pone.0333491 · Cited by 4
Metadata
- Authors
- Huang, D., Zhao, D., Li, J., Wu, Y., Zhou, W., Wang, W., Liang, Z., & Li, Z.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 250
- Pages
- 703-711
- ISSN
- 0925-4005
- Cited by
- 28
- References
- 0
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- National Natural Science Foundation of China (91323304)
- National Key Research and Development Program of China (2016YFA0200802)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High cell viability microfluidic electroporation in a curved channel. https://app.cochat.ai/papers/10.1016/j.snb.2017.04.085
- The paper
- Huang, D., Zhao, D., Li, J., Wu, Y., Zhou, W., Wang, W., Liang, Z., & Li, Z. (2017). High cell viability microfluidic electroporation in a curved channel. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2017.04.085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.