Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Smartphone based optical biosensor for the detection of urea in saliva

Soni, Anuradha, Surana, Rajat Kumar, Jha, Sandeep Kumar·2018·Sensors and Actuators B: Chemical

Abstract

Abstract In the present study, we have developed a smartphone based handheld optical biosensor for determination of urea in saliva. A simple strategy was adopted by immobilization of urease enzyme along with a pH indicator on a filter paper based strip. The strip changed color upon the reaction with urea present in saliva and the color change can be estimated using our smartphone based application based on RGB profiling. Calibration of the biosensor was carried out using spiked saliva samples and an exponentially decreasing calibration curve has been obtained for green pixel intensity in the broad range (10–1000 mgdL−1) with a linear detection range of 10–260 mgdL−1 and a response time of 20 s. The sensitivity reported for the biosensor in the clinically significant range was −0.005 average pixels sec−1/mgdL−1 with a LOD of 10.4 mgdL−1. Studies carried out on spiked saliva samples showed a good correlation between salivary urea estimated using our biosensor against phenol-hypochlorite based spectroscopic procedure. Development of a smartphone based biosensor for urea estimation eliminates the need for procuring a dedicated instrument as well as trained technician for daily monitoring and saves time as compared to traditional laboratory methods of analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2018.04.108

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 169

Metadata

Authors
Soni, A., Surana, R. K., & Jha, S. K.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2018-09
Volume
269
Pages
346-353
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2801674256
Cited by
169
References
5
FWCI
5.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Smartphone based optical biosensor for the detection of urea in saliva. https://app.cochat.ai/papers/10.1016/j.snb.2018.04.108
The paper
Soni, A., Surana, R. K., & Jha, S. K. (2018). Smartphone based optical biosensor for the detection of urea in saliva. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.04.108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.