The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
Abstract
A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer and polydimethyl siloxane (PDMS) were employed as the biosensor material. The biosensor consists of a flexible Pt working electrode and a Ag/AgCl reference/counter electrode, which were formed by micro-electro-mechanical systems (MEMS) technique. The electrode at the sensing region was modified with glucose oxidase (GOD). The CL biosensor showed a good relationship between the output current and glucose concentration in a range of 0.03-5.0mM, with a correlation coefficient of 0.999. The calibration range covered the reported tear glucose concentrations in normal and diabetic patients. Also, the CL biosensor was applied to a rabbit for the purpose of tear glucose monitoring. The basal tear glucose was estimated to 0.11 mM. Also, the change of tear glucose induced by the change of blood sugar level was assessed by the oral glucose tolerance test. As a result, tear glucose level increased with a delay of 10 min from blood sugar level. The result showed that the CL biosensor is expected to provide further detailed information about the relationship between dynamics of blood glucose and tear glucose.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These reversible optical sensors can quantify a wide range of analytes including pH,73 metal ions,74 carbohydrates,75 and alcohol,76 as well as temperature.77”
From Wearables in Medicine (2018) · cites this paper as [74]
In the citing paper
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [100]
In the citing paper
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
In the citing paper
“By considering the correlation between the tear glucose level and blood glucose level (15), a glucose sensor fitted on a contact lens can provide the noninvasive monitoring of user’s glucose levels from tear fluids with a consideration of the lag time between tear glucose level and blood glucose level in the range of 10 to 20 min (13–16).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
In the citing paper
“These issues include (i) the use of opaque electronic materials for sensors, integrated circuit (IC) chips, metal antennas, and interconnects that can block users’ vision (15, 17, 18);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
Citations
Cites
Wild, S., Roglic, G., Green, A., Sicree, R., & King, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1047 · Cited by 15,297
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Stress monitoring using a distributed wireless intelligent sensor system
Jovanov, E., Lords, A. O., Raŝković, D., Cox, P. G., Adhami, R. R., & Andrasik, F. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213626 · Cited by 372
Tear glucose levels in normal people and in diabetic patients.
Sen, D. K., & Sarin, G. S. (1980) · British Journal of Ophthalmology · doi:10.1136/bjo.64.9.693 · Cited by 203
Shervedani, R. K., Hatefi‐Mehrjardi, A., & Zamiri, N. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.01.003 · Cited by 190
Elimination of the Acetaminophen Interference in an Implantable Glucose Sensor
Zhang, Y., Hu, Y., Wilson, G. S., Moatti-Sirat, D., Poitout, V., & Reach, G. (1994) · Analytical Chemistry · doi:10.1021/ac00079a038 · Cited by 184
A novel amperometric biosensor based on NiO hollow nanospheres for biosensing glucose
Li, C., Liu, Y., Li, L., Du, Z., Xu, S., Zhang, M., Yin, X., & Wang, T. (2008) · Talanta · doi:10.1016/j.talanta.2008.06.048 · Cited by 184
Tear Glucose Dynamics in Diabetes Mellitus
Lane, J., Krumholz, D. M., Sack, R. A., & Morris, C. (2006) · Current Eye Research · doi:10.1080/02713680600976552 · Cited by 160
Research works printed but not linked: 12
- Abel, 1984, Biomed. Biochim. Acta, 43, 577
- Shichiri, 1984, Biomed. Biochim. Acta, 43, 561
- Michail, 1937, C. R. Soc. Biol., 125, 1095
- Motoji, 1971, Jpn. J. Clin. Ophthalmol., 25, 1945
- Ridley, 1930, Br. J. Exp. Pathol., 11, 217
- Gssset, 1968, Am. J. Ophthalmol., 65, 414, 10.1016/0002-9394(68)93093-6 · DOI
- Daum, 1982, Invest. Ophthalmol. Vis. Sci., 22, 509
- Gaur, 1982, Indian J. Ophthalmol., 30, 367
- Desai, 1987, Indian J. Ophthalmol., 35, 130
- S.A. Asher, J.T. Baca, Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues by Valery V. Tuchin, (Editor) Taylor & Francis, Pub., New York, Chap. 13 (2009) 387–417.
- Kuizenga, 1987, Invest. Ophthalmol. Vis. Sci., 28, 305
- Wilson, 1993, Invest. Ophthalmol. Vis. Sci., 34, 2752
Cited by
Sorted by citations
Items 101–200 of 279
Tiwari, N., Chatterjee, S., Kaswan, K., Chung, J.-H., Fan, K., & Lin, Z. (2022) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2022.116064 · Cited by 45
Low dimensional materials for glucose sensing
Xu, L., Zhang, X., Wang, Z., Haidry, A. A., Yao, Z., Haque, E., Wang, Y., Li, G., Daeneke, T., McConville, C. F., et al. (2021) · Nanoscale · doi:10.1039/d1nr02529e · Cited by 44
Prakashan, D., Ramya, P. R., & Gandhi, S. (2023) · Diagnostics · doi:10.3390/diagnostics13050916 · Cited by 45
Wearable biosensors for human fatigue diagnosis: A review
Zhang, J., Chen, M., Peng, Y., Li, S., Han, D., Ren, S., Qin, K., Li, S., Han, T., Wang, Y., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10318 · Cited by 44
Yun, J., Zeng, Y., Kim, M., Gao, C., Kim, Y., Lu, L., Kim, T. T.-H., Zhao, W., Bae, T., & Lee, S. W. (2021) · Nano Letters · doi:10.1021/acs.nanolett.0c04362 · Cited by 43
Wearable Ion Sensors for the Detection of Sweat Ions Fabricated by Heat-Transfer Printing
Shitanda, I., Muramatsu, N., Kimura, R., Takahashi, N., Watanabe, K., Matsui, H., Loew, N., Motosuke, M., Mukaimoto, T., Kobayashi, M., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.3c01027 · Cited by 43
CMOS image sensor-based implantable glucose sensor using glucose-responsive fluorescent hydrogel
Tokuda, T., Takahashi, M., Uejima, K., Masuda, K., Kawamura, T., Ohta, Y., Motoyama, M., Noda, T., Sasagawa, K., Okitsu, T., et al. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003859 · Cited by 42
Wireless Communication and Power Harvesting in Wearable Contact Lens Sensors
Yuan, M., Das, R., McGlynn, E., Ghannam, R., Abbasi, Q. H., & Heidari, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3055077 · Cited by 42
Fiber optic biosensor for transdermal glucose based on the glucose binding protein
Tiangco, C. E., Fon, D., Sardesai, N., Kostov, Y. V., Sevilla, F. B., III, Rao, G., & Tolosa, L. M. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.077 · Cited by 39
Biosensors for health applications
Gouvêa, C. M. C. P. (2011) · InTech eBooks · doi:10.5772/16983 · Cited by 38
An electrochromic alarm system for smart contact lenses
Kim, M., Jung, I. D., Kim, Y., Yun, J., Gao, C., Lee, H., & Lee, S. W. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128601 · Cited by 37
Spintronic Sensors Based on Magnetic Tunnel Junctions for Wireless Eye Movement Gesture Control
Tanwear, A., Liang, X., Liu, Y., Vučković, A., Ghannam, R., Böhnert, T., Paz, E., Freitas, P. P., Ferreira, R., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3027242 · Cited by 39
Current development in wearable glucose meters
Chen, Q., Zhao, Y. J., & Liu, Y. (2021) · Chinese Chemical Letters · doi:10.1016/j.cclet.2021.05.043 · Cited by 40
Diabetes and contact lens wear
O’Donnell, C., & Efron, N. (2012) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2012.00738.x · Cited by 35
Advanced Nanoscale Build‐Up Sensors for Daily Life Monitoring of Diabetics
El‐Safty, S. A., & Shenashen, M. A. (2020) · Advanced Materials Interfaces · doi:10.1002/admi.202000153 · Cited by 35
Seetasang, S., & Xu, Y. (2022) · Journal of Materials Chemistry B · doi:10.1039/d1tb02675e · Cited by 35
Fabricated Micro‐Nano Devices for In vivo and In vitro Biomedical Applications
Barkam, S., Saraf, S., & Seal, S. (2013) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1236 · Cited by 35
Real Time Analysis of Bioanalytes in Healthcare, Food, Zoology and Botany
Wang, T., Ramnarayanan, A., & Cheng, H. (2017) · Sensors · doi:10.3390/s18010005 · Cited by 34
Yu, P., Qi, L., Guo, Z., Lin, S., Liu, Y., & Zhao, J. (2022) · Materials & Design · doi:10.1016/j.matdes.2022.110388 · Cited by 34
Current and Future Perspectives on Microfluidic Tear Analytic Devices
Li, M. S., Wong, H. L., Ip, Y. L., Peng, Z., Yiu, R. S. W., Yuan, H. R., Wong, J. K. W., & Chan, Y. K. (2022) · ACS Sensors · doi:10.1021/acssensors.2c00569 · Cited by 35
Wireless‐Powered Electrical Bandage Contact Lens for Facilitating Corneal Wound Healing
Wu, Q., Yang, C., Chen, W., Chen, K., Chen, H., Liu, F., Liu, D., Lin, H., Xie, X., & Chen, W. (2022) · Advanced Science · doi:10.1002/advs.202202506 · Cited by 35
Andoralov, V., Shleev, S., Arnebrant, T., & Ruzgas, T. A. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-6756-x · Cited by 34
Microfluidic Wearable Devices for Sports Applications
Ju, F., Wang, Y., Yin, B., Zhao, M., Zhang, Y., Gong, Y., & Jiao, C. (2023) · Micromachines · doi:10.3390/mi14091792 · Cited by 35
Zhou, Y., Li, L., Tong, J., Chen, X., Deng, W., Chen, Z., Xiao, X., Yin, Y., Zhou, Q., Gao, Y., et al. (2024) · Journal of Materials Chemistry B · doi:10.1039/d4tb00790e · Cited by 33
Advanced implantable energy storage for powering medical devices
Wang, S., Wei, L., Wang, F., Wang, L., & Mao, J. (2025) · eScience · doi:10.1016/j.esci.2025.100409 · Cited by 34
Boselli, L., Pomili, T., Donati, P. P., & Pompa, P. P. (2021) · Materials · doi:10.3390/ma14081978 · Cited by 34
Chen, J., Fang, Z., Azam, A., Wu, X., Zhang, Z., Lu, L., & Li, D. (2022) · Energy · doi:10.1016/j.energy.2022.125472 · Cited by 32
Powering electronic contact lenses: current achievements, challenges, and perspectives
Blum, Z., Pankratov, D., & Shleev, S. (2014) · Expert Review of Ophthalmology · doi:10.1586/17469899.2014.922873 · Cited by 33
Non-invasive blood glucose measurement of 95% certainty by pressure regulated Mid-IR
Chen, J. Y., Zhou, Q., Xu, G., Wang, R. T., Tai, E. G., Xie, L., Qianzhi, Z., Guan, Y., & Huang, X. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.034 · Cited by 33
Self‐Moisturizing Smart Contact Lens Employing Electroosmosis
Kusama, S., Sato, K., Yoshida, S., & Nishizawa, M. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900889 · Cited by 30
Joshi, S., Bhatt, V. D., Wu, H., Becherer, M., & Lugli, P. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2707521 · Cited by 31
Photonic Nanomaterials for Wearable Health Solutions
Park, T., Leem, J. W., Kim, Y. L., & Lee, C. H. (2025) · Advanced Materials · doi:10.1002/adma.202418705 · Cited by 29
Zheng, X. H., Liu, Z., Liu, J., Hu, C., Du, Y., Li, J., Pan, Z., & Ding, K. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c22895 · Cited by 30
Electrochemical Sensing in Contact Lenses
Liu, H., Yan, X., Gu, Z., Xiu, G., & Xiao, X. (2021) · Electroanalysis · doi:10.1002/elan.202100342 · Cited by 29
Development of Nucleic‐Acid‐Based Electrochemical Biosensors for Clinical Applications
Zhang, Z., Sen, P., Adhikari, B. R., Li, Y., & Soleymani, L. (2022) · Angewandte Chemie · doi:10.1002/ange.202212496 · Cited by 28
Noninvasive Glucose Sensing In Vivo
Leung, H. M. C., Forlenza, G. P., Prioleau, T., & Zhou, X. (2023) · Sensors · doi:10.3390/s23167057 · Cited by 31
Highlights of selected recent electrochemical measurements in living systems
Trouillon, R., Svensson, M. I., Berglund, E. C., Cans, A.-S. U., & Ewing, A. G. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.164 · Cited by 28
Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes
Du, X., Durgan, C. J., Matthews, D. J., Motley, J. R., Tan, X., Pholsena, K., Árnadóttir, L., Castle, J. R., Jacobs, P. G., Cargill, R. S., et al. (2015) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.0101504jss · Cited by 28
Screen‐printed Tattoo Sensor towards the Non‐invasive Assessment of the Skin Barrier
Guzman, K. D., & Morrin, A. (2016) · Electroanalysis · doi:10.1002/elan.201600572 · Cited by 28
Wearables technology for drug abuse detection: A survey of recent advancement
Mahmud, M. S., Fang, H., Carreiro, S., Wang, H., & Boyer, E. W. (2018) · Smart Health · doi:10.1016/j.smhl.2018.09.002 · Cited by 27
Application of Silicone in Ophthalmology: A Review
Mladenović, T., Živić, F., Petrovic, N. T., Nježić, S., Pavić, J., Kotorčević, N., Milenković, S., & Grujović, N. (2024) · Materials · doi:10.3390/ma17143454 · Cited by 27
Kim, M., Kim, S., Kwon, Y. W., Seo, H., Chung, W. G., Kim, E., Park, W., Song, H., Lee, D. H., Lee, J., et al. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202200049 · Cited by 26
Flexible Sensors for IoT-Based Health Monitoring
Majumder, S., Roy, A. K., Mondal, T. K., & Deen, M. J. (2025) · IEEE Journal on Flexible Electronics · doi:10.1109/jflex.2025.3538808 · Cited by 25
Wearable and implantable bioelectronic: Biosensing contact lens and applications
Sarac, B., Yücer, S., Sahin, H., Ünal, M., & Çiftçi, F. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.152016 · Cited by 26
From new materials to advanced biomedical applications of solid-state biosensor: A review
Tabata, M., & Miyahara, Y. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131033 · Cited by 25
A review of non-invasive blood glucose monitoring through breath acetone and body surface
Liu, H., Liu, W., Sun, C., Huang, W.-Z., & Cui, X. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115500 · Cited by 25
Small-volume detection: platform developments for clinically-relevant applications
Sung, W.-H., Tsao, Y., Shen, C., Tsai, C., & Cheng, C. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-021-00852-1 · Cited by 24
Electrochemical biosensors for early detection of cancer
Choudhary, M., & Arora, K. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823424-2.00024-7 · Cited by 24
Mehta, P., Haj‐Ahmad, R., Al-Kinani, A. A., Arshad, M. S., Chang, M., Alany, R. G., & Ahmad, Z. (2017) · Therapeutic Delivery · doi:10.4155/tde-2017-0018 · Cited by 24
Recent advances in the study of tear biomarkers and contact lens-based biosensors
Bai, W., Yu, X., Li, Q., Tan, H., Ma, K., Bai, H., Li, S., Hu, J. H., Yao, Y., Zhuang, W., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.156540 · Cited by 24
Towards organic electronics that learn at the body-machine interface: A materials journey
Roh, H., Cunin, C. E., Samal, S., & Gumyusenge, A. (2022) · MRS Communications · doi:10.1557/s43579-022-00269-3 · Cited by 22
Microfluidic Immunosensor for Point-of-Care-Testing of Beta-2-Microglobulin in Tear
Maity, S., Ghosh, S., Bhuyan, T., Das, D., & Bandyopadhyay, D. (2020) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c00289 · Cited by 22
Xu, Q., Xi, Y., Wang, L., Xu, M., Ruan, T., Du, Z., Jiang, C., Cao, J., Zhu, X., Wang, X., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116173 · Cited by 21
Wearable biosensors and sample handling strategies
Parlak, O., Curto, V. F., Ojeda, E., Basabe‐Desmonts, L., Benito‐Lopez, F., & Salleo, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102407-2.00004-7 · Cited by 20
Modern noninvasive methods for monitoring glucose levels in patients: a review
Dziergowska, K., Łabowska, M. B., Gąsior‐Głogowska, M., Kmiecik, B., & Detyna, J. D. (2019) · Bio-Algorithms and Med-Systems · doi:10.1515/bams-2019-0052 · Cited by 18
Han, J. H., Cho, Y. C., Koh, W., & Choy, Y. B. (2020) · PLoS ONE · doi:10.1371/journal.pone.0239317 · Cited by 17
Non-Enzymatic Amperometric Glucose Screen-Printed Sensors Based on Copper and Copper Oxide Particles
Guati, C., Gómez‐Coma, L., Fallanza, M., & Ortíz, I. (2021) · Applied Sciences · doi:10.3390/app112210830 · Cited by 17
Advancements in enzyme-based wearable sensors for health monitoring
Mehrotra, S., Rai, P., Saxena, A., Priya, S., & Sharma, S. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110250 · Cited by 17
Passive Diffusion of Transdermal Glucose
Kanjananimmanont, S., Ge, X., Mupparapu, K., Rao, G., Potts, R. O., & Tolosa, L. M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813519994 · Cited by 17
Review of point-of-care platforms for diabetes: (1) sensing
Liu, Y., Luo, X., Yu, Q., Ye, L., Yang, L., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100113 · Cited by 19
Park, S., Nam, D. Y., Jeon, H., Han, J. H., Jang, D., Hwang, J., Park, Y.-S., Han, Y., Choy, Y. B., & Lee, D. Y. (2023) · Biomaterials Research · doi:10.1186/s40824-023-00469-5 · Cited by 18
A contact lens with integrated micro solar cells
Lingley, A. R., Otis, B. P., Shen, T. T., & Parviz, B. A. (2012) · Microsystem Technologies · doi:10.1007/s00542-011-1417-5 · Cited by 17
A Disposable Tear Glucose Biosensor—Part 3: Assessment of Enzymatic Specificity
Lan, K., McAferty, K., Shah, P., Lieberman, E., Patel, D. R., Cook, C. B., & Belle, J. T. L. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500511 · Cited by 16
Tao, H., Zhang, X., Sun, Y., Yang, H., & Lin, B. (2016) · Colloid & Polymer Science · doi:10.1007/s00396-016-4001-9 · Cited by 15
Recent progress of continuous intraocular pressure monitoring
Xu, J., Li, R., Xu, H., Yang, Y., Zhang, S., & Ren, T. (2021) · Nano Select · doi:10.1002/nano.202100137 · Cited by 14
Hosseinian, H., Hosseini, S., Martinez-Chapa, S. O., & Sher, M. (2022) · Polymers · doi:10.3390/polym14010185 · Cited by 16
Three-Dimensionally Printed Interconnects for Smart Contact Lenses
Kim, H., Kim, J., Kang, J., & Song, Y. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b08675 · Cited by 14
Power Scavenging Microsystem for Smart Contact Lenses
Pourshaban, E., Karkhanis, M. U., Deshpande, A., Banerjee, A., Hasan, M. R., Nikeghbal, A., Ghosh, C., Kim, H., & Mastrangelo, C. H. (2024) · Small · doi:10.1002/smll.202401068 · Cited by 15
Miniaturized power-integrated and self-powered sensor systems for advanced biomedical applications
Yun, J., Keerthana, S., & Kwon, S. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100260 · Cited by 12
Takamatsu, T., Yin, S., & Miyake, T. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201704 · Cited by 13
Wearable Devices for Biofluid Monitoring in a Body: from Lab to Commercialization
Yang, Y. J., Lee, S. G., & Kim, T. (2024) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-024-00295-y · Cited by 13
Micro-structured light emission from planar InGaN light-emitting diodes
Massoubre, D., Xie, E., Guilhabert, B., Herrnsdorf, J., Gu, E., Watson, I. M., & Dawson, M. D. (2013) · Semiconductor Science and Technology · doi:10.1088/0268-1242/29/1/015005 · Cited by 15
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12
Mouth guard type biosensor “cavitous sensor” for monitoring of saliva glucose with telemetry system
Arakawa, T., Kuroki, Y., Nitta, H., Toma, K., Mitsubayashi, K., Takeuchi, S., Sekita, T., & Minakuchi, S. (2015) · International Conference on Sensing Technology · doi:10.1109/icsenst.2015.7438362 · Cited by 11
Self-citationMukherjee, S., & Mukherjee, N. (2021) · Studies in systems, decision and control · doi:10.1007/978-981-15-9612-4_1 · Cited by 11
Trends in Epidermal Stretchable Electronics for Noninvasive Long-term Healthcare Applications
Han, H., Reichmuth, A. M., Renz, A. F., Stauffer, F., Thielen, M., & Vörös, J. (2017) · International Journal of Automation and Smart Technology · doi:10.5875/ausmt.v7i2.1336 · Cited by 10
VIS/NIR/FIR spectroscopy for blood glucose monitoring: A review
Chen, Q., Zhang, W., & Wu, W. (2025) · AIP Advances · doi:10.1063/5.0239187 · Cited by 9
Innovations in wearable biosensors: A pathway to 24/7 personalized healthcare
Singh, I., Kumar, S., & Koh, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117938 · Cited by 10
Capillary flow in microchannel circuitry of scleral lenses
Yetisen, A. K., Soylemezoglu, B., Dong, J., Montelongo, Y., Butt, H., Jakobi, M., & Koch, A. W. (2019) · RSC Advances · doi:10.1039/c9ra01094g · Cited by 9
Echem methods and electrode types of the current in vivo electrochemical sensing
Song, Q., Li, Q., Yan, J., & Song, Y. (2022) · RSC Advances · doi:10.1039/d2ra01273a · Cited by 9
Quantification of tear glucose levels and their correlation with blood glucose levels in dogs
Lee, E., Kang, S., Shim, J., Jeong, D., Jeong, Y., Ahn, J., & Seo, K. (2022) · Veterinary Medicine and Science · doi:10.1002/vms3.788 · Cited by 8
Wearable Electrochemical Biosensors for Glucose Monitoring
Majdinasab, M. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_3 · Cited by 7
Tokuda, T., Kawamura, T., Masuda, K., Hirai, T., Takehara, H., Ohta, Y., Motoyama, M., Takehara, H., Noda, T., Sasagawa, K., et al. (2016) · IEEE Design and Test · doi:10.1109/mdat.2016.2560137 · Cited by 7
Sharma, A., Bhat, S., Dasgupta, D., Samantara, L., Kalyanachakravarthi, K., Manchanda, B., Shah, C. P., Saxena, A., Choudhury, V., & Mondal, T. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.49198 · Cited by 7
Materials for wearable sensors
Purohit, B., divya, D. D., Shetti, N. P., & Chandra, P. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00012-4 · Cited by 7
Advances in Wearable Sensing Technologies and Their Impact for Personalized and Preventive Medicine
Nasiri, N., & Tricoli, A. (2018) · InTech eBooks · doi:10.5772/intechopen.76916 · Cited by 7
Suppression of protein adsorption on a graphene surface by phosphorylcholine functionalization
Taniguchi, Y., Miki, T., Ohno, Y., Nagase, M., Arakawa, Y., Imada, Y., Minagawa, K., & Yasuzawa, M. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab0b37 · Cited by 7
Paper-based surfaced enhanced Raman spectroscopy for drug level testing with tear fluid
Yamada, K., Yokoyama, M., Jeong, H., Kido, M., & Ohno, Y. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2192833 · Cited by 7
Cavitas Sensors (Soft Contact Lens Type Biosensor, Mouth-Guard Type Sensor, etc.) for Daily Medicine
Arakawa, T., & Mitsubayashi, K. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-47319-2_3 · Cited by 7
Self-citationEmerging horizons of MXenes in wearable sensors for advanced health monitoring: an overview
Shingange, K., & Mokhena, T. C. (2026) · Frontiers in Sensors · doi:10.3389/fsens.2025.1704186 · Cited by 6
Sharma, R., Srivastav, S., & Meher, S. K. (2023) · New Journal of Chemistry · doi:10.1039/d3nj02799f · Cited by 6
Innovative advancement of contact lenses for noninvasive diagnosis and therapy: A mini review
Wen, X., Liu, Q., & Zhang, M. (2023) · MedComm – Biomaterials and Applications · doi:10.1002/mba2.40 · Cited by 6
3.34 Biomaterials Challenges in Continuous Glucose Monitors In Vivo
Rao, A. N., Avula, M., & Grainger, D. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09314-0 · Cited by 7
Tan, C. M. E., Dizon, G. V., Chen, S.-H., Venault, A., Chou, Y.-N., Tayo, L. L., & Chang, Y. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb01478h · Cited by 6
Silica/antibody-conjugated microcomb electrode sensor for cardiac biomarker analysis
Li, J., Li, H., Xu, J., Zhao, X., Song, S., Xue, Z., Wu, Y. S., Gopinath, S. C. B., Lakshmipriya, T., & Zhang, H. (2021) · Applied Physics A · doi:10.1007/s00339-020-04260-4 · Cited by 6
Yazdani, J., Mafatia, K., Harun-Or-Rashid, M., Jabbour, J., Preda, V. A., & Nasiri, N. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118209 · Cited by 7
Determination diabetes mellitus disease markers in tear fluid by photothermal AFM-IR analysis
Kondrakhova, D., Unger, M. V., Stadler, H., Zakuťanská, K., Tomašovičová, N., Tomečková, V., Horák, J., Kimáková, T., & Komanický, V. (2025) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2025.102803 · Cited by 6
Nano-biosensors for Diagnosing Infectious and Lifestyle-Related Disease of Human: An Update
Padma, S., Chakraborty, P., & Mukherjee, S. (2022) · Springer eBooks · doi:10.1007/978-981-19-7130-3_4 · Cited by 5
Multi-models with averaging in feature domain for non-invasive blood glucose estimation
Wei, Y., Ling, B. W., Liu, Q., & Liu, J. (2022) · IEEE International Symposium on Product Compliance Engineering - Asia (ISPCE-ASIA) · doi:10.1109/ispce-asia57917.2022.9971019 · Cited by 5
Hashim, A. J., Ghazai, A. J., Jaafar, M. S., Mansor, N., & Zain, Z. M. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)16510-2 · Cited by 5
Metadata
- Authors
- Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Mitsubayashi, K.
- Affiliations
- Tokyo Medical and Dental University (JP)
- Kansai University (JP)
- Corresponding author
- Mitsubayashi, Kohji
- ORCID
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 83
- Issue
- 3
- Pages
- 960-965
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2007320634
- Cited by
- 279
- References
- 29
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 24 · 2023: 25 · 2022: 27 · 2021: 32 · 2020: 30 · 2019: 24 · 2018: 19 · 2017: 15 · 2016: 17 · 2015: 13 · 2014: 15 · 2013: 4 · 2012: 8
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science
- Ministry of Education, Culture, Sports, Science and Technology
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- tear glucose, non-invasive glucose monitoring, glucose oxidase, platinum electrode, MEMS electrodes, 2-methacryloyloxyethyl phosphorylcholine, polydimethylsiloxane, diabetes mellitus, oral glucose tolerance test, blood glucose dynamics
- MeSH terms
- Animals, Blood Glucose, Contact Lenses, Hydrophilic, Humans, Rabbits, Tears, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review