The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
Abstract
A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer and polydimethyl siloxane (PDMS) were employed as the biosensor material. The biosensor consists of a flexible Pt working electrode and a Ag/AgCl reference/counter electrode, which were formed by micro-electro-mechanical systems (MEMS) technique. The electrode at the sensing region was modified with glucose oxidase (GOD). The CL biosensor showed a good relationship between the output current and glucose concentration in a range of 0.03-5.0mM, with a correlation coefficient of 0.999. The calibration range covered the reported tear glucose concentrations in normal and diabetic patients. Also, the CL biosensor was applied to a rabbit for the purpose of tear glucose monitoring. The basal tear glucose was estimated to 0.11 mM. Also, the change of tear glucose induced by the change of blood sugar level was assessed by the oral glucose tolerance test. As a result, tear glucose level increased with a delay of 10 min from blood sugar level. The result showed that the CL biosensor is expected to provide further detailed information about the relationship between dynamics of blood glucose and tear glucose.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These reversible optical sensors can quantify a wide range of analytes including pH,73 metal ions,74 carbohydrates,75 and alcohol,76 as well as temperature.77”
From Wearables in Medicine (2018) · cites this paper as [74]
In the citing paper
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [100]
In the citing paper
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
In the citing paper
“By considering the correlation between the tear glucose level and blood glucose level (15), a glucose sensor fitted on a contact lens can provide the noninvasive monitoring of user’s glucose levels from tear fluids with a consideration of the lag time between tear glucose level and blood glucose level in the range of 10 to 20 min (13–16).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
In the citing paper
“These issues include (i) the use of opaque electronic materials for sensors, integrated circuit (IC) chips, metal antennas, and interconnects that can block users’ vision (15, 17, 18);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
Citations
Cites
Wild, S., Roglic, G., Green, A., Sicree, R., & King, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1047 · Cited by 15,297
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Stress monitoring using a distributed wireless intelligent sensor system
Jovanov, E., Lords, A. O., Raŝković, D., Cox, P. G., Adhami, R. R., & Andrasik, F. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213626 · Cited by 372
Tear glucose levels in normal people and in diabetic patients.
Sen, D. K., & Sarin, G. S. (1980) · British Journal of Ophthalmology · doi:10.1136/bjo.64.9.693 · Cited by 203
Shervedani, R. K., Hatefi‐Mehrjardi, A., & Zamiri, N. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.01.003 · Cited by 190
Elimination of the Acetaminophen Interference in an Implantable Glucose Sensor
Zhang, Y., Hu, Y., Wilson, G. S., Moatti-Sirat, D., Poitout, V., & Reach, G. (1994) · Analytical Chemistry · doi:10.1021/ac00079a038 · Cited by 184
A novel amperometric biosensor based on NiO hollow nanospheres for biosensing glucose
Li, C., Liu, Y., Li, L., Du, Z., Xu, S., Zhang, M., Yin, X., & Wang, T. (2008) · Talanta · doi:10.1016/j.talanta.2008.06.048 · Cited by 184
Tear Glucose Dynamics in Diabetes Mellitus
Lane, J., Krumholz, D. M., Sack, R. A., & Morris, C. (2006) · Current Eye Research · doi:10.1080/02713680600976552 · Cited by 160
Development of the Implantable Glucose Sensor: What Are the Prospects and Why Is It Taking So Long?
Gough, D., & Armour, J. C. (1995) · Diabetes · doi:10.2337/diab.44.9.1005 · Cited by 118
Pickup, J. C., Shaw, G. W., & Claremont, D. J. (1989) · Diabetologia · doi:10.1007/bf00265097 · Cited by 114
Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
Baca, J. T., Taormina, C. R., Feingold, E., Finegold, D. N., Grabowski, J. J., & Asher, S. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.078543 · Cited by 110
Yu, J., Yu, D., Zhao, T., & Zeng, B. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.005 · Cited by 110
Analysis of tear glucose concentration with electrospray ionization mass spectrometry
Taormina, C. R., Baca, J. T., Asher, S. A., Grabowski, J. J., & Finegold, D. N. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.10.002 · Cited by 99
On-Chip Integration of Enzyme and Immunoassays: Simultaneous Measurements of Insulin and Glucose
Wang, J., Ibáñez, A., & Chatrathi, M. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja036067e · Cited by 95
Shichiri, M., Kawamori, R., Hakui, N., Yamasaki, Y., & Abe, H. (1984) · Diabetes · doi:10.2337/diab.33.12.1200 · Cited by 85
Haeringen, N. J. V., & Glasius, E. (1977) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00496763 · Cited by 75
Concentration of Glucose and Total Chloride in Tears
Giardini, A., & Roberts, J. R. E. (1950) · British Journal of Ophthalmology · doi:10.1136/bjo.34.12.737 · Cited by 72
Tear Glucose Detection of Hyperglycemia
Gasset, A. R., Braverman, L. E., Fleming, M. C., Arky, R. A., & Alter, B. R. (1968) · American Journal of Ophthalmology · doi:10.1016/0002-9394(68)93093-6 · Cited by 68
Galeska, I., Hickey, T., Moussy, F. G., Kreutzer, D. L., & Papadimitrakopoulos, F. (2001) · Biomacromolecules · doi:10.1021/bm010112y · Cited by 62
Miniaturized fiber-optic hybrid sensor for continuous glucose monitoring in subcutaneous tissue
Pasic, A., Koehler, H., Klimant, I., & Schaupp, L. A. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.05.010 · Cited by 53
In vivo life sign application of dielectric spectroscopy and non-invasive glucose monitoring
Talary, M. S., Dewarrat, F., Huber, D., & Caduff, A. (2007) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2007.03.038 · Cited by 50
Khan, F., Gnudi, L., & Pickup, J. C. (2007) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2007.10.129 · Cited by 47
Lewis, J. G., & Stephens, P. J. (1958) · British Journal of Ophthalmology · doi:10.1136/bjo.42.12.754 · Cited by 35
Wilkins, E. S., & Wilkins, M. (1983) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(83)90006-7 · Cited by 23
A blood-assisted optical biosensor for automatic glucose determination
Sanz, V., de Marcos, S., & Galbán, J. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.060 · Cited by 15
Chemically Sensitive Field Effect Transistor as a Potential Implantable Glucose Sensor
Janata, J. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.271 · Cited by 8
First European Conference on Antennas and Propagation, 2006 (EuCAP 2006)
Matthaiou, M., Razavi‐Ghods, N., Laurenson, D. I., & Salous, S. (2006) · European Conference on Antennas and Propagation · Cited by 5
Research works printed but not linked: 12
- Abel, 1984, Biomed. Biochim. Acta, 43, 577
- Shichiri, 1984, Biomed. Biochim. Acta, 43, 561
- Michail, 1937, C. R. Soc. Biol., 125, 1095
- Motoji, 1971, Jpn. J. Clin. Ophthalmol., 25, 1945
- Ridley, 1930, Br. J. Exp. Pathol., 11, 217
- Gssset, 1968, Am. J. Ophthalmol., 65, 414, 10.1016/0002-9394(68)93093-6 · DOI
- Daum, 1982, Invest. Ophthalmol. Vis. Sci., 22, 509
- Gaur, 1982, Indian J. Ophthalmol., 30, 367
- Desai, 1987, Indian J. Ophthalmol., 35, 130
- S.A. Asher, J.T. Baca, Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues by Valery V. Tuchin, (Editor) Taylor & Francis, Pub., New York, Chap. 13 (2009) 387–417.
- Kuizenga, 1987, Invest. Ophthalmol. Vis. Sci., 28, 305
- Wilson, 1993, Invest. Ophthalmol. Vis. Sci., 34, 2752
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 915
Gonzales, W. V., Mobashsher, A. T., & Abbosh, A. M. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 820
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Metadata
- Authors
- Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Mitsubayashi, K.
- Affiliations
- Tokyo Medical and Dental University (JP)
- Kansai University (JP)
- Corresponding author
- Mitsubayashi, Kohji
- ORCID
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 83
- Issue
- 3
- Pages
- 960-965
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2007320634
- Cited by
- 279
- References
- 29
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 24 · 2023: 25 · 2022: 27 · 2021: 32 · 2020: 30 · 2019: 24 · 2018: 19 · 2017: 15 · 2016: 17 · 2015: 13 · 2014: 15 · 2013: 4 · 2012: 8
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science
- Ministry of Education, Culture, Sports, Science and Technology
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- tear glucose, non-invasive glucose monitoring, glucose oxidase, platinum electrode, MEMS electrodes, 2-methacryloyloxyethyl phosphorylcholine, polydimethylsiloxane, diabetes mellitus, oral glucose tolerance test, blood glucose dynamics
- MeSH terms
- Animals, Blood Glucose, Contact Lenses, Hydrophilic, Humans, Rabbits, Tears, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review