Cited by 85Electrochemical sensors and biosensorsOcular Surface and Contact LensAdvanced Sensor and Energy Harvesting Materials

Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents

Chu, MingXing, Shirai, Takayuki, Takahashi, Daishi, Arakawa, Takahiro, Kudo, Hiroyuki, Sano, Kenji, Sawada, Shin-ichi, Yano, Kazuyoshi +4 more·2011·Biomedical Microdevices

Abstract

A soft contact-lens biosensor (SCL-biosensor) for novel non-invasive biomonitoring of tear fluids was fabricated and tested. Wearing a biosensor on eye enabled the in situ monitoring of tear contents. The biosensor has an enzyme immobilized electrode on the surface of a polydimethyl siloxane (PDMS) contact lens. The SCL-biosensor was fabricated using microfabrication techniques for functional polymers (PDMS and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer). In investigation of in vitro characterization, the SCL-biosensor showed excellent relationship between the output current and glucose concentration from 0.03 to 5.0 mmol·L(-1), with a correlation coefficient of 0.994. The calibration range covered the reported tear glucose concentrations (0.14 mmol·L(-1)). Based on the result, ocular biomonitoring with the SCL-biosensor was carried out. The SCL-biosensor well worked both in the static state and the dynamic state. The tear glucose level of rabbit was estimated to 0.12 mmol·L(-1) at first and then the tear turnover was successfully calculated to be 29.6 ± 8.42% min(-1). The result indicated that SCL-biosensor is useful for advanced biomonitoring on eye.

Integrity signals

Registry

Crossref · 10.1007/s10544-011-9530-x

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting diffusion from the lachrymal artery when tears are sampled without eye irritation or stimulation, which can compromise the relationship.

    “In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [101]

Cites

Flagged first, then by citations

2 of the 39 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Chu, M., Shirai, T., Takahashi, D., Arakawa, T., Kudo, H., Sano, K., Sawada, S.-I., Yano, K., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Mitsubayashi, K.
Affiliations
  • Tokyo Medical and Dental University (JP)
  • Tokyo University of Technology (JP)
  • Kansai University (JP)
Corresponding author
Mitsubayashi, Kohji
Venue
Biomedical Microdevices
Published
2011-04-08
Volume
13
Issue
4
Pages
603-611
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W2043624863
Cited by
85
References
39
Citations by year
2026: 2 · 2025: 1 · 2024: 9 · 2023: 6 · 2022: 5 · 2021: 11 · 2020: 9 · 2019: 4 · 2018: 8 · 2017: 8 · 2016: 8 · 2015: 4 · 2014: 6 · 2013: 1 · 2012: 3
FWCI
2.24
Type
journal article
Language
en
Open access
closed
Locations
  • Biomedical Microdevices (publishedVersion)
  • PubMed (publishedVersion)
Funders
Japan Society for the Promotion of Science (21650041)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
non-invasive biomonitoring, 2-methacryloyloxyethyl phosphorylcholine, rabbit eye
MeSH terms
Animals, Calibration, Contact Lenses, Hydrophilic, Dimethylpolysiloxanes, Eye, Glucose, Methacrylates, Phosphorylcholine, Rabbits, Tears, Vision, Ocular, Biosensing Techniques, Biomedical Technology, Microtechnology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›