The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
Abstract
A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer and polydimethyl siloxane (PDMS) were employed as the biosensor material. The biosensor consists of a flexible Pt working electrode and a Ag/AgCl reference/counter electrode, which were formed by micro-electro-mechanical systems (MEMS) technique. The electrode at the sensing region was modified with glucose oxidase (GOD). The CL biosensor showed a good relationship between the output current and glucose concentration in a range of 0.03-5.0mM, with a correlation coefficient of 0.999. The calibration range covered the reported tear glucose concentrations in normal and diabetic patients. Also, the CL biosensor was applied to a rabbit for the purpose of tear glucose monitoring. The basal tear glucose was estimated to 0.11 mM. Also, the change of tear glucose induced by the change of blood sugar level was assessed by the oral glucose tolerance test. As a result, tear glucose level increased with a delay of 10 min from blood sugar level. The result showed that the CL biosensor is expected to provide further detailed information about the relationship between dynamics of blood glucose and tear glucose.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These reversible optical sensors can quantify a wide range of analytes including pH,73 metal ions,74 carbohydrates,75 and alcohol,76 as well as temperature.77”
From Wearables in Medicine (2018) · cites this paper as [74]
In the citing paper
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [100]
In the citing paper
“(iv) the requirement for bulky and expensive equipment for signal measurements, which limits the use of smart contact lenses outside of research laboratories or clinical settings by restricting users’ external activities (14, 15, 20, 23).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
In the citing paper
“By considering the correlation between the tear glucose level and blood glucose level (15), a glucose sensor fitted on a contact lens can provide the noninvasive monitoring of user’s glucose levels from tear fluids with a consideration of the lag time between tear glucose level and blood glucose level in the range of 10 to 20 min (13–16).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
In the citing paper
“These issues include (i) the use of opaque electronic materials for sensors, integrated circuit (IC) chips, metal antennas, and interconnects that can block users’ vision (15, 17, 18);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [15]
Citations
Cites
Wild, S., Roglic, G., Green, A., Sicree, R., & King, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1047 · Cited by 15,297
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Wireless sensor networks for personal health monitoring: Issues and an implementation
Milenković, A., Otto, C., & Jovanov, E. (2006) · Computer Communications · doi:10.1016/j.comcom.2006.02.011 · Cited by 1,023
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Stress monitoring using a distributed wireless intelligent sensor system
Jovanov, E., Lords, A. O., Raŝković, D., Cox, P. G., Adhami, R. R., & Andrasik, F. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213626 · Cited by 372
Tear glucose levels in normal people and in diabetic patients.
Sen, D. K., & Sarin, G. S. (1980) · British Journal of Ophthalmology · doi:10.1136/bjo.64.9.693 · Cited by 203
Shervedani, R. K., Hatefi‐Mehrjardi, A., & Zamiri, N. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.01.003 · Cited by 190
Elimination of the Acetaminophen Interference in an Implantable Glucose Sensor
Zhang, Y., Hu, Y., Wilson, G. S., Moatti-Sirat, D., Poitout, V., & Reach, G. (1994) · Analytical Chemistry · doi:10.1021/ac00079a038 · Cited by 184
A novel amperometric biosensor based on NiO hollow nanospheres for biosensing glucose
Li, C., Liu, Y., Li, L., Du, Z., Xu, S., Zhang, M., Yin, X., & Wang, T. (2008) · Talanta · doi:10.1016/j.talanta.2008.06.048 · Cited by 184
Tear Glucose Dynamics in Diabetes Mellitus
Lane, J., Krumholz, D. M., Sack, R. A., & Morris, C. (2006) · Current Eye Research · doi:10.1080/02713680600976552 · Cited by 160
Research works printed but not linked: 12
- Abel, 1984, Biomed. Biochim. Acta, 43, 577
- Shichiri, 1984, Biomed. Biochim. Acta, 43, 561
- Michail, 1937, C. R. Soc. Biol., 125, 1095
- Motoji, 1971, Jpn. J. Clin. Ophthalmol., 25, 1945
- Ridley, 1930, Br. J. Exp. Pathol., 11, 217
- Gssset, 1968, Am. J. Ophthalmol., 65, 414, 10.1016/0002-9394(68)93093-6 · DOI
- Daum, 1982, Invest. Ophthalmol. Vis. Sci., 22, 509
- Gaur, 1982, Indian J. Ophthalmol., 30, 367
- Desai, 1987, Indian J. Ophthalmol., 35, 130
- S.A. Asher, J.T. Baca, Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues by Valery V. Tuchin, (Editor) Taylor & Francis, Pub., New York, Chap. 13 (2009) 387–417.
- Kuizenga, 1987, Invest. Ophthalmol. Vis. Sci., 28, 305
- Wilson, 1993, Invest. Ophthalmol. Vis. Sci., 34, 2752
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 915
Gonzales, W. V., Mobashsher, A. T., & Abbosh, A. M. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 820
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Park, J., Kim, J., Kim, S.-Y., Cheong, W. H., Jang, J., Park, Y.-G., Na, K., Kim, Y.-T., Heo, J. H., Lee, C. Y., et al. (2018) · Science Advances · doi:10.1126/sciadv.aap9841 · Cited by 671
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Shrivastava, S., Trung, T. Q., & Lee, N. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 500
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Liu, Y., Wang, H., Zhao, W., Zhang, M., Qin, H., & Xie, Y. (2018) · Sensors · doi:10.3390/s18020645 · Cited by 404
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2019) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2019.100523 · Cited by 391
Review on Micro- and Nanolithography Techniques and their Applications
Pimpin, A., & Srituravanich, W. (2012) · Engineering Journal · doi:10.4186/ej.2012.16.1.37 · Cited by 399
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 387
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S.-I., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., et al. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.014 · Cited by 356
Self-citationWearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 352
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 307
Current and Emerging Technology for Continuous Glucose Monitoring
Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z., Qian, S., & Flewitt, A. J. (2017) · Sensors · doi:10.3390/s17010182 · Cited by 300
Electrochemical Glucose Sensing: Is There Still Room for Improvement?
Nery, E. W., Kundys, M., Jeleń, P. S., & Jönsson‐Niedziółka, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03151 · Cited by 297
Niu, X., Li, X., Pan, J., He, Y., Qiu, F., & Yan, Y. (2016) · RSC Advances · doi:10.1039/c6ra12506a · Cited by 276
Recent advances in the synthesis of smart hydrogels
Sikdar, P. P., Uddin, M. M., Dip, T. M., Islam, S., Hoque, M. S., Dhar, A. K., & Wu, S. (2021) · Materials Advances · doi:10.1039/d1ma00193k · Cited by 267
Direct electron transfer based enzymatic fuel cells
Falk, M., Blum, Z., & Shleev, S. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2011.12.133 · Cited by 260
On‐Body Bioelectronics: Wearable Biofuel Cells for Bioenergy Harvesting and Self‐Powered Biosensing
Jeerapan, I., Sempionatto, J. R., & Wang, J. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906243 · Cited by 243
Arwani, R. T., Tan, S. C. L., Sundarapandi, A., Goh, W. P., Liu, Y., Leong, F. Y., Yang, W., Zheng, X. T., Yu, Y., Ang, Y. C., et al. (2024) · Nature Materials · doi:10.1038/s41563-024-01918-9 · Cited by 239
Corrie, S. R., Coffey, J. W., Islam, J., Markey, K. A., & Kendall, M. A. F. (2015) · The Analyst · doi:10.1039/c5an00464k · Cited by 220
Biofuel cell as a power source for electronic contact lenses
Falk, M., Andoralov, V., Blum, Z., Sotres, J., Suyatin, D. B., Ruzgas, T. A., Arnebrant, T., & Shleev, S. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.04.030 · Cited by 215
Wearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208
Internet of medical things: A systematic review
Huang, C., Wang, J., Wang, S., & Zhang, Y. (2023) · Neurocomputing · doi:10.1016/j.neucom.2023.126719 · Cited by 199
Metabolomics for the masses: The future of metabolomics in a personalized world
Trivedi, D. K., Hollywood, K. A., & Goodacre, R. (2017) · European Journal of Molecular & Clinical Medicine · doi:10.1016/j.nhtm.2017.06.001 · Cited by 201
Integrated contact lens sensor system based on multifunctional ultrathin MoS2 transistors
Guo, S., Wu, K., Li, C., Wang, H., Sun, Z., Xi, D., Zhang, S., Ding, W., Zaghloul, M. E., Wang, C., et al. (2020) · Matter · doi:10.1016/j.matt.2020.12.002 · Cited by 182
Miniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Zhang, M., Wang, X., Feng, H., Huang, Q., Xiao, X., & Zhang, X. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.127712 · Cited by 181
Kownacka, A. E., Vegelyte, D., Joosse, M., Anton, N., Toebes, B. J., Lauko, J., Buzzacchera, I., Lipinska, K., Wilson, D. A., Geelhoed-Duijvestijn, N., et al. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b01429 · Cited by 164
Wen, F., He, T., Liu, H., Chen, H., Zhang, T., & Lee, C. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105155 · Cited by 160
Contact lens biofuel cell tested in a synthetic tear solution
Reid, R. C., Minteer, S. D., & Gale, B. K. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.12.034 · Cited by 159
Tseng, R. C., Chen, C.-C., Hsu, S., & Chuang, H.-S. (2018) · Sensors · doi:10.3390/s18082651 · Cited by 156
Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Seo, H., Chung, W. G., Kwon, Y. W., Kim, S., Hong, Y., Park, W., Kim, E., Lee, J., Lee, S., Kim, M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00290 · Cited by 157
A single-pixel wireless contact lens display
Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., et al. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/12/125014 · Cited by 148
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems
Kim, K., Kim, B., & Lee, C. H. (2019) · Advanced Materials · doi:10.1002/adma.201902051 · Cited by 148
Recent patient health monitoring platforms incorporating internet of things-enabled smart devices
Kang, M., Park, E., Cho, B. H., & Lee, K.-S. (2018) · International Neurourology Journal · doi:10.5213/inj.1836144.072 · Cited by 143
Flexible plastic, paper and textile lab-on-a chip platforms for electrochemical biosensing
Economou, A., Kokkinos, C., & Prodromidis, M. I. (2018) · Lab on a Chip · doi:10.1039/c8lc00025e · Cited by 144
Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135
Nanoporous Gold-Based Biofuel Cells on Contact Lenses
Xiao, X., Siepenkoetter, T., Conghaile, P. Ó., Leech, D., & Magner, E. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18708 · Cited by 133
Organic Electronics for Point-of-Care Metabolite Monitoring
Pappa, A., Parlak, O., Scheiblin, G., Mailley, P., Salleo, A., & Owens, R. M. (2017) · Trends in biotechnology · doi:10.1016/j.tibtech.2017.10.022 · Cited by 131
Lab‐on‐a‐Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics
Zhu, Y., Li, S., Li, J., Falcone, N., Cui, Q., Shah, S., Hartel, M. C., Yu, N., Young, P., de Barros, N. R., et al. (2022) · Advanced Materials · doi:10.1002/adma.202108389 · Cited by 125
Recent Advances in Smart Contact Lenses
Kim, J., Cha, E., & Park, J. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900728 · Cited by 120
Barnett, M., Courey, C., Fadel, D., Lee, K. S., Michaud, L., Montani, G., van der Worp, E., Vincent, S. J., Walker, M. K., Bilkhu, P. S., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.001 · Cited by 113
System Architectures in Wearable Electrochemical Sensors
Steinberg, M. D., Kassal, P., & Steinberg, I. M. (2016) · Electroanalysis · doi:10.1002/elan.201600094 · Cited by 110
Wearable fluorescent contact lenses for monitoring glucose via a smartphone
Deng, M., Song, G., Zhong, K., Wang, Z., Xi, X., & Tian, Y. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131067 · Cited by 106
A Nanotechnology-Based Approach to Biosensor Application in Current Diabetes Management Practices
Shoaib, A., Darraj, A., Khan, M. E., Azmi, L., Alalwan, A., Alamri, O., Tabish, M., & Khan, A. U. (2023) · Nanomaterials · doi:10.3390/nano13050867 · Cited by 104
Hydrogel-based flexible materials for diabetes diagnosis, treatment, and management
Jiang, S., Zhang, Y., Chan, S. Y., Du, Z., Yan, Y., Wang, T., Li, P., & Huang, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00122-y · Cited by 102
Biosensors and Chemical Sensors for Healthcare Monitoring: A Review
Arakawa, T., Dao, D. V., & Mitsubayashi, K. (2022) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23580 · Cited by 102
Self-citationBody-Interfaced Chemical Sensors for Noninvasive Monitoring and Analysis of Biofluids
Zhao, J., Guo, H., Li, J., Bandodkar, A. J., & Rogers, J. A. (2019) · Trends in Chemistry · doi:10.1016/j.trechm.2019.07.001 · Cited by 96
Smart Skin‐Adhesive Patches: From Design to Biomedical Applications
Wong, S. H. D., Deen, G. R., Bates, J. S., Maiti, C., Lam, C. Y. K., Pachauri, A., AlAnsari, R., Bělský, P., Yoon, J., & Dodda, J. M. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202213560 · Cited by 95
Safarkhani, M., Aldhaher, A., Heidari, G., Zare, E. N., Warkiani, M. E., Akhavan, O., Huh, Y. S., & Rabiee, N. (2023) · Nano Materials Science · doi:10.1016/j.nanoms.2023.11.009 · Cited by 94
Soft and flexible material-based affinity sensors
Meng, L., Turner, A. P. F., & Mak, W. C. (2019) · Biotechnology Advances · doi:10.1016/j.biotechadv.2019.05.004 · Cited by 94
Development of Nucleic‐Acid‐Based Electrochemical Biosensors for Clinical Applications
Zhang, Z., Sen, P., Adhikari, B. R., Li, Y., & Soleymani, L. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202212496 · Cited by 91
Shitanda, I., Fujimura, Y., Takarada, T., Suzuki, R., Aikawa, T., Itagaki, M., & Tsujimura, S. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01266 · Cited by 93
Sonner, Z., Wilder, E., Gaillard, T. R., Kasting, G. B., & Heikenfeld, J. C. (2017) · Lab on a Chip · doi:10.1039/c7lc00364a · Cited by 91
Application of Microfluidics in Wearable Devices
Chen, G., Zheng, J., Liu, L., & Xu, L. (2019) · Small Methods · doi:10.1002/smtd.201900688 · Cited by 90
Recent Developments of Flexible and Stretchable Electrochemical Biosensors
Yang, X., & Cheng, H. (2020) · Micromachines · doi:10.3390/mi11030243 · Cited by 89
Wearable and Implantable Intraocular Pressure Biosensors: Recent Progress and Future Prospects
Yang, C., Huang, X., Li, X., Yang, C., Zhang, T., Wu, Q., Liu, D., Lin, H., Chen, W., Hu, N., et al. (2021) · Advanced Science · doi:10.1002/advs.202002971 · Cited by 87
Noninvasive Glucose Monitoring with a Contact Lens and Smartphone
Lin, Y.-R., Hung, C.-C., Chiu, H., Chang, P.-H., Li, B., Cheng, S.-J., Yang, J., Lin, S., & Chen, G. (2018) · Sensors · doi:10.3390/s18103208 · Cited by 86
Near-field sub-diffraction photolithography with an elastomeric photomask
Paik, S., Kim, G., Chang, S., Lee, S., Jin, D., Jeong, K., Lee, I. S., Lee, J., Moon, H., Lee, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-14439-1 · Cited by 84
Agustini, D., Bergamini, M. F., & Junior, L. H. M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.035 · Cited by 81
Shitanda, I., Mitsumoto, M., Loew, N., Yoshihara, Y., Watanabe, H., Mikawa, T., Tsujimura, S., Itagaki, M., & Motosuke, M. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.137620 · Cited by 80
Goldoni, R., Dolci, C., Boccalari, E., Inchingolo, F., Paghi, A., Strambini, L. M., Galimberti, D., & Tartaglia, G. M. (2022) · Ageing Research Reviews · doi:10.1016/j.arr.2022.101587 · Cited by 86
Inkjet printed flexible non-enzymatic glucose sensor for tear fluid analysis
Romeo, A., Moya, A., Leung, T., Gabriel, G., Villa, R., & Sánchez, S. (2018) · Applied Materials Today · doi:10.1016/j.apmt.2017.12.016 · Cited by 75
Clinical Opportunities for Continuous Biosensing and Closed-Loop Therapies
Li, J., Liang, J., Laken, S. J., Langer, R., & Traverso, G. (2020) · Trends in Chemistry · doi:10.1016/j.trechm.2020.02.009 · Cited by 74
Approaches of wearable and implantable biosensor towards of developing in precision medicine
Ghazizadeh, E., Naseri, Z., Deigner, H.-P., Rahimi, H., & Altıntaş, Z. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1390634 · Cited by 78
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Self-citationMicro/nanofiber-based noninvasive devices for health monitoring diagnosis and rehabilitation
Ghosh, R., Pin, K. Y., Reddy, V. S., Jayathilaka, W. A. D. M., Ji, D., Garcia, W. S., Bhargava, S. K., Ramakrishna, S., & Chinnappan, A. (2020) · Applied Physics Reviews · doi:10.1063/5.0010766 · Cited by 71
Ophthalmic Sensors and Drug Delivery
Savariraj, A. D., Salih, A. E., Alam, F., Elsherif, M., AlQattan, B., Khan, A. A., Yetisen, A. K., & Butt, H. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00370 · Cited by 69
Cui, X., Liu, X., Yu, X., Cai, W., & Shao, X. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.004 · Cited by 68
Noninvasive Continuous Monitoring of Tear Glucose Using Glucose‐Sensing Contact Lenses
Ascaso, F. J., & Huerva, V. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000698 · Cited by 68
dos Santos, C. C., Lucena, G. N., Pinto, G. C., Jafelicci, M., & Marques, R. F. C. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10130 · Cited by 68
Theoretical Insight on the Biosensing Applications of 2D Materials
Vaidyanathan, A., Mathew, M., Radhakrishnan, S., Rout, C. S., & Chakraborty, B. (2020) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.0c08539 · Cited by 65
Wearable Smart Contact Lenses for Continual Glucose Monitoring: A Review
Elsherif, M., Moreddu, R., Alam, F., Salih, A. E., Ahmed, I., & Butt, H. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.858784 · Cited by 68
Flexible, wearable microfluidic contact lens with capillary networks for tear diagnostics
Yang, X., Yao, H., Zhao, G., Ameer, G. A., Sun, W., Yang, J. H., & Mi, S. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-04688-2 · Cited by 64
Fluorescence Sensing Technologies for Ophthalmic Diagnosis
Shi, Y., Hu, Y., Jiang, N., & Yetisen, A. K. (2022) · ACS Sensors · doi:10.1021/acssensors.2c00313 · Cited by 64
Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids
Falk, M., Psotta, C., Cirovic, S., & Shleev, S. (2020) · Sensors · doi:10.3390/s20216352 · Cited by 62
Novel gold nanozyme regulation strategies facilitate analytes detection
Wang, Z., Shao, Y., Zhu, Z., Wang, J., Gao, X., Xie, J., Wang, Y., Wu, Q., Shen, Y., & Ding, Y. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215369 · Cited by 58
Smart contact Lenses: From rational design strategies to wearable health monitoring
Han, F., Ge, P., Wang, F., Yang, Y., Chen, S., Kang, J., Ren, Y., Liu, H., Zhao, W., He, Y., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.154823 · Cited by 56
Wearable Carbon Nanotube-Based Biosensors on Gloves for Lactate
Luo, X., Shi, W., Yu, H., Xie, Z., Li, K., & Cui, Y. (2018) · Sensors · doi:10.3390/s18103398 · Cited by 54
Tear-Based Ocular Wearable Biosensors for Human Health Monitoring
Arunima Rajan, S., Vishnu, J., & Shankar, B. (2024) · Biosensors · doi:10.3390/bios14100483 · Cited by 55
Multifunctional High‐Power Sources for Smart Contact Lenses
Takamatsu, T., Yin, S., Shujie, F., Liu, X., & Miyake, T. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906225 · Cited by 53
Hondred, J. A., Johnson, Z. T., & Claussen, J. C. (2020) · Journal of Materials Chemistry C · doi:10.1039/d0tc01423k · Cited by 53
Fiber-crafted biofuel cell bracelet for wearable electronics
Yin, S., Liu, X., Kaji, T., Nishina, Y., & Miyake, T. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113107 · Cited by 50
The ocular surface and diabetes, the other 21st Century epidemic
Bu, Y., Shih, K. C., & Tong, L. H. T. (2022) · Experimental Eye Research · doi:10.1016/j.exer.2022.109099 · Cited by 51
Direct Electron Transfer of Enzymes in a Biologically Assembled Conductive Nanomesh Enzyme Platform
Lee, S., Lee, K., Song, Y., Choi, W. K., Chang, J., & Yi, H. (2015) · Advanced Materials · doi:10.1002/adma.201503930 · Cited by 49
Recent progress on wearable point-of-care devices for ocular systems
Shin, H., Seo, H., Chung, W. G., Joo, B. J., Jang, J., & Park, J. (2021) · Lab on a Chip · doi:10.1039/d0lc01317j · Cited by 49
Park, S., Hwang, J., Jeon, H., Bae, W. R., Jeong, I.-K., Kim, T. G., Kang, J., Han, Y.-G., Chung, E., & Lee, D. Y. (2021) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c00603 · Cited by 50
Ophthalmic sensing technologies for ocular disease diagnostics
Shi, Y., Jiang, N., Bikkannavar, P., Cordeiro, M. F., & Yetisen, A. K. (2021) · The Analyst · doi:10.1039/d1an01244d · Cited by 50
Jung, H. H., Lee, H., Yea, J., & Jang, K. (2024) · Soft Science · doi:10.20517/ss.2024.02 · Cited by 50
Zhang, J., Xiong, Q., & Xu, J. (2024) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2024.108643 · Cited by 49
Wearable Bifocal Contact Lens for Continual Glucose Monitoring Integrated with Smartphone Readers
Elsherif, M., Alam, F., Salih, A. E., AlQattan, B., Yetisen, A. K., & Butt, H. (2021) · Small · doi:10.1002/smll.202102876 · Cited by 51
Comparative Analysis of Tear Composition in Humans, Domestic Mammals, Reptiles, and Birds
Raposo, A. C., Portela, R. W., Aldrovani, M., Barral, T. D., Oliveira, D. C. D. A., & Oriá, A. P. (2020) · Frontiers in Veterinary Science · doi:10.3389/fvets.2020.00283 · Cited by 47
Noninvasive Self-diagnostic Device for Tear Collection and Glucose Measurement
Lee, S. H., Cho, Y. C., & Choy, Y. B. (2019) · Scientific Reports · doi:10.1038/s41598-019-41066-8 · Cited by 47
Metadata
- Authors
- Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., & Mitsubayashi, K.
- Affiliations
- Tokyo Medical and Dental University (JP)
- Kansai University (JP)
- Corresponding author
- Mitsubayashi, Kohji
- ORCID
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 83
- Issue
- 3
- Pages
- 960-965
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2007320634
- Cited by
- 279
- References
- 29
- Citations by year
- 2026: 10 · 2025: 12 · 2024: 24 · 2023: 25 · 2022: 27 · 2021: 32 · 2020: 30 · 2019: 24 · 2018: 19 · 2017: 15 · 2016: 17 · 2015: 13 · 2014: 15 · 2013: 4 · 2012: 8
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science
- Ministry of Education, Culture, Sports, Science and Technology
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- tear glucose, non-invasive glucose monitoring, glucose oxidase, platinum electrode, MEMS electrodes, 2-methacryloyloxyethyl phosphorylcholine, polydimethylsiloxane, diabetes mellitus, oral glucose tolerance test, blood glucose dynamics
- MeSH terms
- Animals, Blood Glucose, Contact Lenses, Hydrophilic, Humans, Rabbits, Tears, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›