The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A thin film polyethylene terephthalate (PET) electrochemical sensor for detection of glucose in sweat
Abstract
In this work, a thin film PET based gold electrode (PGE) glucose sensor was fabricated through ultraviolet mediated chemical plating technique. Compared with the most existing wearable thin film gold electrode sensors, the PGE-glucose sensor is simple, low cost and minimum instrumentation was required. The proposed glucose sensor revealed a sensitivity of 22.05 μA mM-1 cm-2 in a linear range from 0.02 to 1.11 mM with a low detection limit of 2.7 μM (S/N = 3). The PGE-glucose sensor had a good selectivity and was not interfered by lactic acid, urea, acetaminophen, uric acid, dopamine and ascorbic acid. Additionally, it exhibited good reproducibility and long-term stability over four weeks. Finally, the disposable PGE-glucose sensor was successfully applied to determine the glucose in sweat and commercial beverage accurately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationCorrelation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Cited by
Occurrence, toxicity and remediation of polyethylene terephthalate plastics. A review
Dhaka, V., Singh, S., Anil, A. G., Sunil Kumar Naik, T. S., Garg, S., Samuel, J., Kumar, M., Ramamurthy, P. C., & Singh, J. (2022) · Environmental Chemistry Letters · doi:10.1007/s10311-021-01384-8 · Cited by 331
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Li, Q.-F., Chen, X., Wang, H., Liu, M., & Peng, H.-L. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c20543 · Cited by 255
Li, G., & Wen, D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02474c · Cited by 119
Pillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Metadata
- Authors
- Wang, Y., Wang, X., Lu, W., Yuan, Q., Zheng, Y., & Yao, B.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 198
- Pages
- 86-92
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2913338101
- Cited by
- 166
- References
- 8
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A thin film polyethylene terephthalate (PET) electrochemical sensor for detection of glucose in sweat. https://app.cochat.ai/papers/10.1016/j.talanta.2019.01.104
- The paper
- Wang, Y., Wang, X., Lu, W., Yuan, Q., Zheng, Y., & Yao, B. (2019). A thin film polyethylene terephthalate (PET) electrochemical sensor for detection of glucose in sweat. Talanta. https://doi.org/10.1016/j.talanta.2019.01.104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.