Effect of different methods for outlier detection and rejection when calculating cut off values for diagnosis of lupus anticoagulants
Abstract
Background Lupus anticoagulant (LA)-detection is performed by testing plasma with activated partial thromboplastin time (APTT)-derived and dilute-Russell-viper-venom (dRVV)-derived tests. Results are interpreted by comparison to cut-off values determined by testing plasma from healthy-subjects. Several issues are concerned with the determination of LA cut-offs. Among them, the identification/rejection of outliers (i.e., aberrant values) prior statistical analysis is one of the most important and poorly defined.Objectives The primary aim of this collaborative study was to evaluate whether outliers' identification/removal by using three algorithms prior cut-off calculation would have any effect on the between-laboratory variability of cut-offs. As a secondary aim, we evaluated whether and to what extent outliers' removal would affect LA-detection rate.Methods Data sets stemming from 120 plasmas from healthy-donors, collected and tested at each of 11 laboratories were evaluated by three algorithms for outliers' identification. Furthermore, a well characterized set of plasmas certified as being positive at increasing LA-potency, were concomitantly tested and their results used to assess any effect of outlier detection/rejection on LA-detection rate.Results Relatively few outliers were identified and their elimination (regardless of algorithms) showed no appreciable effects on the inter-laboratory variability of cut-offs nor on the LA-detection rate, indicating that outliers are not the main cause of the inter-laboratory variability of cut-offs for LA-detection.Conclusions These results strengthen the recommendation that cut-offs should be determined locally after outlier removal (to avoid inclusion of gross, obvious outliers) and that they cannot be interchangeably used in other laboratories even when using the same platform.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The authors of the multicenter study recommended identifying outliers before cutoff calculation using one of the available algorithms.
“This notwithstanding, the authors recommended the identification of outliers before cutoff calculation by using one of the current available algorithms.74”
A study of three commercial LA platforms following ISTH-SSC guidelines found platform-to-platform differences in clotting times and ratios, and differences among participants using the same platform, even after outlier exclusion.
“Differences were observed between platforms for clotting times as well as results expressed as ratio, but also between participants using the same platform.These differences were observed even after detection and exclusion of outliers before cutoff calculation.74”
Cites
BARNETT, V. D., Lewis, T., & Abeles, F. F. (1979) · Physics Today · doi:10.1063/1.2995737 · Cited by 2,834 · see citing works
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197 · see citing works
Self-citationDixon, W. J. (1953) · Biometrics · doi:10.2307/3001634 · Cited by 872 · see citing works
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740 · see citing works
Influence of statistical method used on the resulting estimate of normal range.
Reed, A. H., Henry, R. J., & Mason, W. B. (1971) · Clinical Chemistry · doi:10.1093/clinchem/17.4.275 · Cited by 598 · see citing works
Testing for Antiphospholipid antibodies with Solid Phase Assays: guidance from the SSC of the ISTH
Devreese, K. M. J., Pierangeli, S. S., de Laat, B., Tripodi, A., Atsumi, T., & Ortel, T. L. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12537 · Cited by 224 · see citing works
Self-citationDetection and Quantitative Evaluation of Lupus Circulating Anticoagulant Activity
Rosner, E., Pauzner, R., Lusky, A., Modan, M., & Many, A. (1987) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1651083 · Cited by 188 · see citing works
Nonparametric Estimation of Reference Intervals by Simple and Bootstrap-based Procedures
Línnet, K. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.6.867 · Cited by 125 · see citing works
Buckland, W. R. (1979) · Journal of the Operational Research Society · doi:10.1057/jors.1979.165 · Cited by 103 · see citing works
Chantarangkul, V., Tripodi, A., Arbini, A., & Mannucci, P. M. (1992) · Thrombosis Research · doi:10.1016/0049-3848(92)90266-d · Cited by 52 · see citing works
Self-citationPengo, V., Biasiolo, A., Gresele, P., Marongiu, F., Erba, N., Veschi, F., Ghirarduzzi, A., Barcellona, D., & Tripodi, A. (2007) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.107.153536 · Cited by 49 · see citing works
Self-citationTripodi, A., Chantarangkul, V., Cini, M., Devreese, K., Dlott, J. S., Giacomello, R., Gray, E., Legnani, C., Martinuzzo, M. E., Pradella, P., et al. (2017) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13678 · Cited by 35 · see citing works
Self-citationVanoverschelde, L., Kelchtermans, H., Musial, J., de Laat, B., & Devreese, K. M. J. (2019) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12207 · Cited by 33 · see citing works
Improved reference-interval estimation.
Shultz, E. K., Willard-Gallo, K. E., Rich, S. S., Connelly, D. P., & Critchfield, G. C. (1985) · Clinical Chemistry · doi:10.1093/clinchem/31.12.1974 · Cited by 30 · see citing works
Moore, G. W., & Kumano, O. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14669 · Cited by 18 · see citing works
Tripodi, A., Chantarangkul, V., Clerici, M., Palmucci, C., Bison, E., Banzato, A., Biguzzi, E., & Pengo, V. (2011) · Thrombosis Research · doi:10.1016/j.thromres.2011.01.015 · Cited by 8 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Devreese, K. M. J., de Groot, P. G., de Laat, B., Erkan, D., Favaloro, E. J., Mackie, I., Martinuzzo, M., Ortel, T. L., Pengo, V., Rand, J. H., et al. (2020) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15047 · Cited by 439 · see citing works
Self-citationAnalytical dilemmas in lupus anticoagulant detection
Moore, G. W. (2023) · Exploration of Immunology · doi:10.37349/ei.2023.00104 · Cited by 5 · see citing works
- Authors
- Chantarangkul, V., Peyvandi, F., & Tripodi, A.
- Affiliations
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT)
- University of Milan (IT)
- Corresponding author
- Tripodi, Armando
- Venue
- Thrombosis Research
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 190
- Pages
- 20-25
- ISSN
- 0049-3848 (ISSN-L)
- OpenAlex
- W3013354104
- Cited by
- 8
- References
- 16
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 1
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Thrombosis Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Keywords
- lupus anticoagulant, cut-off values, outlier detection, outlier removal, inter-laboratory variability, activated partial thromboplastin time
- MeSH terms
- Anticoagulants, Blood Coagulation Tests, Humans, Partial Thromboplastin Time, Plasma, Prothrombin Time, Lupus Coagulation Inhibitor, Antiphospholipid Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review