Lupus anticoagulant assay cut‐offs vary between reagents even when derived from a common set of normal donor plasmas

Open access
Moore, Gary W., Kumano, Osamu·2020·Journal of Thrombosis and Haemostasis

Abstract

Background Multicenter studies reveal that diagnostic efficacy of lupus anticoagulant (LA) assays is enhanced if cut-offs are locally generated. However, a potential confounder is the inevitable use of separate normal donor populations.Objectives Generate cut-offs for multiple LA reagents with the same analyzer and normal donor plasmas.Methods Cut-offs for screen ratio, confirm ratio, percent correction of screen ratio by confirm ratio, and normalized screen/confirm ratio (NSCR) were derived from the same 50 normal donor plasmas for screen and confirm pairs for two dilute Russell's viper venom time reagents, LA1/LA2 and HEMOCLOT™ LA-S/LA-C, and two APTTs, Actin FSL/FS and Cephen LS/Cephen. The cut-offs were challenged with plasmas from 20 triple-positive APS patients and 25 plasmas from LA-negative, thrombotic patients.Results Cut-offs for screen ratio, confirm ratio, percent correction, and NSCR, respectively, were 1.12/1.08/8.3/1.09 for LA1/LA2; 1.17/1.10/13.6/1.13 for HEMOCLOT™ LA-S/LA-C; 1.12/1.13/9.7/1.10 for Actin FSL/FS; 1.09/1.13/11.0/1.11 for Cephen LS/Cephen. LA1 and LA-S screens were elevated in 19/20 and 16/20 triple-positive plasmas, respectively, while 20/20 were detected with both via integrated interpretation ie, percent correction or NSCR irrespective of screen elevation. Actin FSL and Cephen LS screens were elevated in 17/20 and 19/20 triple-positive plasmas, respectively, while one more LA was detected with Actin FSL via integrated interpretation, but not for Cephen LS. Integrated interpretation suggested 5/25 LA-negative plasmas contained weak LA (two with Actin FSL/FS, two with LA1/LA2, one with LA-S/LA-R).Conclusions Employing the same normal donor plasmas and analytical platform does not compensate for between-reagent differences when generating LA assay cut-offs.

Integrity signals

Registry

Crossref · 10.1111/jth.14669

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Moore, G. W., & Kumano, O.
Affiliations
  • St Thomas' Hospital (GB)
  • Sysmex (Japan) (JP)
Corresponding author
Moore, Gary W.
Venue
Journal of Thrombosis and Haemostasis
Publisher
Elsevier BV
Published
2020-02
Volume
18
Issue
2
Pages
439-444
ISSN
1538-7836 (ISSN-L)
OpenAlex
W2982390432
Cited by
18
References
24
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 5 · 2022: 2 · 2021: 2 · 2020: 4
FWCI
1.52
Type
journal article
Language
en
Open access
Locations
  • Journal of Thrombosis and Haemostasis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
lupus anticoagulant, Russell's viper venom time, activated partial thromboplastin time, antiphospholipid syndrome, integrated interpretation, thrombosis, reagent comparison
MeSH terms
Blood Coagulation Tests, Humans, Indicators and Reagents, Partial Thromboplastin Time, Prothrombin Time, Lupus Coagulation Inhibitor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review