Electrochemical biosensors based on nanomodified screen-printed electrodes: Recent applications in clinical analysis
Abstract
Abstract This review addresses recent advances in the development of screen-printed electrode based biosensors modified with different nanomaterials such as carbon nanotubes, graphene, metallic nanoparticles as gold, silver and magnetic nanoparticles, and mediator nanoparticles (Prussian Blue, Cobalt Phthalocyanine, etc.), coupled with biological recognition elements such as enzymes, antibodies, DNA and aptamers to obtain probes with improved analytical features. Examples of clinical applications are illustrated, together with examples of paper-based electrochemical devices, of multiple detections using arrays of screen printed electrodes, and of the most recent developments in the field of wearable biosensors. Also the use of smartphones as final detectors is briefly depicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Folding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid Architectures
Lubin, A. A., & Plaxco, K. W. (2010) · Accounts of Chemical Research · doi:10.1021/ar900165x · Cited by 506
Xiao, Y., Lai, R. Y., & Plaxco, K. W. (2007) · Nature Protocols · doi:10.1038/nprot.2007.413 · Cited by 439
Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
Tüdős, A. J., Besselink, G. A. J., & Schasfoort, R. B. M. (2001) · Lab Chip · doi:10.1039/b106958f · Cited by 426
Bahadır, E. B., & Sezgintürk, M. K. (2015) · Analytical Biochemistry · doi:10.1016/j.ab.2015.03.011 · Cited by 424
Carbon and gold electrodes as electrochemical transducers for DNA hybridisation sensors.
Lucarelli, F., Marrazza, G., Turner, A., & Mascini, M. (2004) · Biosensors & bioelectronics · doi:10.1016/s0956-5663(03)00256-2 · Cited by 374
Ruecha, N., Rangkupan, R., Rodthongkum, N., & Chailapakul, O. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.08.018 · Cited by 342
A review on novel developments and applications of immunosensors in food analysis
Ricci, F., Volpe, G., Micheli, L., & Palleschi, G. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.10.046 · Cited by 338
Self-citationA review of experimental aspects of electrochemical immunosensors
Ricci, F., Adornetto, G., & Palleschi, G. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.06.033 · Cited by 327
Self-citationJo, H., Gu, H., Jeon, W., Youn, H., Her, J., Kim, S.-K., Lee, J., Shin, J. H., & Ban, C. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02312 · Cited by 270
Nanotechnology in glucose monitoring: Advances and challenges in the last 10 years
Scognamiglio, V. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.043 · Cited by 266
Howick, J., Cals, J. W. L., Jones, C., Price, C. P., Plüddemann, A., Heneghan, C., Berger, M. Y., Buntinx, F., Hickner, J., Pace, W., et al. (2014) · BMJ Open · doi:10.1136/bmjopen-2014-005611 · Cited by 237
Ping, J., Wang, Y., Fan, K., Wu, J., & Ying, Y. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.018 · Cited by 232
Methods and applications of antibody microarrays in cancer research
Haab, B. B. (2003) · PROTEOMICS · doi:10.1002/pmic.200300595 · Cited by 231
Koydemir, H. C., Gorocs, Z., Tseng, D., Cortazar, B., Feng, S., Chan, R. Y. L., Burbano, J., McLeod, E., & Ozcan, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01358a · Cited by 192
Mahshid, S. S., Camiré, S., Ricci, F., & Vallée-Bélisle, A. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04942 · Cited by 191
Self-citationDetection of Hepatitis B Virus DNA with a Paper Electrochemical Sensor
Li, X., Scida, K., & Crooks, R. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02210 · Cited by 174
Cunningham, J. C., Brenes, N. J., & Crooks, R. M. (2014) · Analytical Chemistry · doi:10.1021/ac501438y · Cited by 160
Jampasa, S., Wonsawat, W., Rodthongkum, N., Siangproh, W., Yanatatsaneejit, P., Vilaivan, T., & Chailapakul, O. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.023 · Cited by 147
Torrente-Rodríguez, R. M., Campuzano, S., Montiel, V. R., et al. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.016 · Cited by 122
Azzouzi, S., Rotariu, L., Benito, A. M., Maser, W. K., Ali, M. B., & Bala, C. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.012 · Cited by 119
Tran, H. V., Piro, B., Reisberg, S., Nguyen, H. L., Nguyen, T. D., Duc, H. T., & Pham, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.014 · Cited by 117
E-DNA sensors for convenient, label-free electrochemical detection of hybridization
Ricci, F., & Plaxco, K. W. (2008) · Microchimica Acta · doi:10.1007/s00604-008-0015-4 · Cited by 110
Self-citationUltrasensitive Norovirus Detection Using DNA Aptasensor Technology
Giamberardino, A., Labib, M., Hassan, E. M., Tetro, J. A., Springthorpe, S., Sattar, S. A., Berezovski, M. V., & DeRosa, M. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079087 · Cited by 110
Bioelectrochemical Switches for the Quantitative Detection of Antibodies Directly in Whole Blood
Vallée‐Bélisle, A., Ricci, F., Uzawa, T., Xia, F., & Plaxco, K. W. (2012) · Journal of the American Chemical Society · doi:10.1021/ja305720w · Cited by 109
Self-citationGold nanoparticles mediated label-free capacitance detection of cardiac troponin I
Bhalla, V., Carrara, S., Sharma, P., Nangia, Y., & Suri, C. R. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.029 · Cited by 108
Song, W., Li, H., Liang, H., Qiang, W., & Xu, D. (2014) · Analytical Chemistry · doi:10.1021/ac500011k · Cited by 108
Cinti, S., Arduini, F., Moscone, D., Palleschi, G., & Killard, A. J. (2014) · Sensors · doi:10.3390/s140814222 · Cited by 103
Self-citationPiermarini, S., Migliorelli, D., Volpe, G., Massoud, R., Pierantozzi, A., Cortese, C., & Palleschi, G. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.10.090 · Cited by 101
Self-citationArduini, F., Forchielli, M., Amine, A., Neagu, D., Cacciotti, I., Nanni, F. M. C., Moscone, D., & Palleschi, G. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1370-y · Cited by 99
Self-citationDeterminants of the Detection Limit and Specificity of Surface-Based Biosensors
de Ávila, B. E., Watkins, H. M., Pingarrón, J. M., Plaxco, K. W., Palleschi, G., & Ricci, F. (2013) · Analytical Chemistry · doi:10.1021/ac4012123 · Cited by 97
Self-citationRe‐engineering Electrochemical Biosensors To Narrow or Extend Their Useful Dynamic Range
Kang, D., Vallée‐Bélisle, A., Porchetta, A., Plaxco, K. W., & Ricci, F. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201202204 · Cited by 89
Self-citationLai, G., Wang, L., Wu, J., Ju, H., & Yan, F. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.048 · Cited by 87
Redox biomarkers in cardiovascular medicine
Galougahi, K. K., Antoniades, C. A., Nicholls, S. J., Channon, K. M., & Figtree, G. A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv126 · Cited by 83
Foster, C. W., Pillay, J., Metters, J. P., & Banks, C. E. (2014) · Sensors · doi:10.3390/s141121905 · Cited by 80
Pribil, M. M., Laptev, G. U., Karyakina, E. E., & Karyakin, A. A. (2014) · Analytical Chemistry · doi:10.1021/ac501547u · Cited by 75
Cinti, S., Arduini, F., Moscone, D., Palleschi, G., Gonzalez‐Macia, L., & Killard, A. J. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.06.054 · Cited by 70
Self-citationSmartphone-based point-of-care testing of salivary α-amylase for personal psychological measurement
Zhang, L., Yang, W., Yang, Y., Liu, H., & Gu, Z. (2015) · The Analyst · doi:10.1039/c5an01664a · Cited by 70
Development of a sandwich format, amperometric screen-printed uric acid biosensor for urine analysis
Kanyong, P., Pemberton, R. M., Jackson, S. K., & Hart, J. P. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.05.027 · Cited by 60
Manickam, P., Sethy, N. K., Bhargava, K., Kameswararao, V., & Karunakaran, C. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.030 · Cited by 59
Ng, B. Y. C., Xiao, W., West, N. P., Wee, E. J. H., Wang, Y., & Trau, M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03121 · Cited by 58
A carbon nanotube screen-printed electrode for label-free detection of the human cardiac troponin T
Silva, B. V. M., Cavalcanti, I. T., Silva, M. M. S., & Dutra, R. F. (2013) · Talanta · doi:10.1016/j.talanta.2013.08.059 · Cited by 56
Huang, J. M.-Y., Henihan, G., Macdonald, D., Michalowski, A., Templeton, K. E., Gibb, A. P., Schulze, H., & Bachmann, T. T. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01270 · Cited by 50
Lebiga, E., Fernandez, R. E., & Beşkök, A. (2015) · The Analyst · doi:10.1039/c5an00720h · Cited by 49
Biagiotti, V., Porchetta, A., Desiderati, S., Plaxco, K. W., Palleschi, G., & Ricci, F. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5361-0 · Cited by 47
Self-citationZhang, Y., Geng, X., Ai, J., Gao, Q., Qi, H., & Zhang, C. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.005 · Cited by 45
Development of an amperometric screen-printed galactose biosensor for serum analysis
Kanyong, P., Pemberton, R. M., Jackson, S. K., & Hart, J. P. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.01.006 · Cited by 45
Michopoulos, A., Kouloumpis, Α., Gournis, D., & Prodromidis, M. I. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.09.031 · Cited by 43
An electrochemical immunoassay for the screening of celiac disease in saliva samples
Adornetto, G., Fabiani, L., Volpe, G., Stefano, A. D., Martini, S., Nenna, R., Lucantoni, F., Bonamico, M., Tiberti, C., & Moscone, D. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8884-y · Cited by 42
Self-citationProtein Electrocatalysis for Direct Sensing of Circulating MicroRNAs
Labib, M., Khan, N., & Berezovski, M. V. (2014) · Analytical Chemistry · doi:10.1021/ac504331c · Cited by 42
Ricci, F., Adornetto, G., Moscone, D., Plaxco, K. W., & Palleschi, G. (2010) · Chemical Communications · doi:10.1039/b922595a · Cited by 34
Self-citationA human telomeric G-quadruplex-based electronic nanoswitch for the detection of anticancer drugs
Bagheryan, Z., Raoof, J. B., Ojani, R., & Rezaei, P. (2015) · The Analyst · doi:10.1039/c4an02010c · Cited by 7
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Fabiani, L., Saroglia, M., Galatà, G., De Santis, R., Fillo, S., Luca, V., Faggioni, G., D'Amore, N., Regalbuto, E., Salvatori, P., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112686 · Cited by 434
Self-citationElectrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Metadata
- Authors
- Arduini, F., Micheli, L., Moscone, D., Palleschi, G., Piermarini, S., Ricci, F., & Volpe, G.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 79
- Pages
- 114-126
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2296591280
- Cited by
- 395
- References
- 63
- FWCI
- 19.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.