The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Electrochemical biosensors based on nanomodified screen-printed electrodes: Recent applications in clinical analysis
Abstract
Abstract This review addresses recent advances in the development of screen-printed electrode based biosensors modified with different nanomaterials such as carbon nanotubes, graphene, metallic nanoparticles as gold, silver and magnetic nanoparticles, and mediator nanoparticles (Prussian Blue, Cobalt Phthalocyanine, etc.), coupled with biological recognition elements such as enzymes, antibodies, DNA and aptamers to obtain probes with improved analytical features. Examples of clinical applications are illustrated, together with examples of paper-based electrochemical devices, of multiple detections using arrays of screen printed electrodes, and of the most recent developments in the field of wearable biosensors. Also the use of smartphones as final detectors is briefly depicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Electrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers
Chikkaveeraiah, B. V., Bhirde, A. A., Morgan, N. Y., Eden, H. S., & Chen, X. (2012) · ACS Nano · doi:10.1021/nn3023969 · Cited by 719
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Fabiani, L., Saroglia, M., Galatà, G., De Santis, R., Fillo, S., Luca, V., Faggioni, G., D'Amore, N., Regalbuto, E., Salvatori, P., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112686 · Cited by 434
Self-citationElectrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 335
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Recent Advances in Electrochemical Immunosensors
Wen, W., Yan, X., Zhu, C., Du, D., & Lin, Y. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04281 · Cited by 313
Review—An Overview on Recent Progress in Screen-Printed Electroanalytical (Bio)Sensors
Singh, S., Wang, J., & Cinti, S. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac70e2 · Cited by 300
The Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Screen-Printed Electrodes: Fabrication, Modification, and Biosensing Applications
Paimard, G., Ghasali, E., & Baeza, M. (2023) · Chemosensors · doi:10.3390/chemosensors11020113 · Cited by 255
Metadata
- Authors
- Arduini, F., Micheli, L., Moscone, D., Palleschi, G., Piermarini, S., Ricci, F., & Volpe, G.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2016-05
- Volume
- 79
- Pages
- 114-126
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2296591280
- Cited by
- 395
- References
- 63
- FWCI
- 19.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.