Headspace mode of liquid phase microextraction: A review
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In recent years, liquid phase microextraction (LPME) as a solvent–minimized and microscale implementation of sample pretreatment procedure of liquid–liquid extraction has been introduced and obtained great attention among the researchers due to its simplicity, low cost, rapidity, and efficiency. Developments have led to different approaches of LPME such as headspace mode of liquid phase microextraction (HS mode of LPME) which is used in the cases of volatile and semi–volatile analytes. In HS mode of LPME, the extractant is suspended in the headspace of analytes solution and has no contact with the sample solution which leads to eliminate interferences problem. The present review discusses HS mode of LPME with the focus on its historical developments, principles, configurations, inherent limitations, and pros and cons. Herein, recent analytical applications of the method used in the isolation and trace enrichment prior to analysis of various compounds are reviewed. The future direction of the researches in this field and general trend toward the commercial applications are also considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Kokosa, J. M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.019 · Cited by 137
Magnetic ionic liquids as extraction solvents in vacuum headspace single-drop microextraction
Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Talanta · doi:10.1016/j.talanta.2017.05.021 · Cited by 81
Wu, Y., Xia, L., Chen, R., & Hu, B. (2008) · Talanta · doi:10.1016/j.talanta.2007.05.057 · Cited by 79
Sun, S.-H., Xie, J.-P., Xie, F.-W., & Zong, Y.-L. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.102 · Cited by 47
Research works printed but not linked: 66
- Yazdi, 2010, Liquid–phase microextraction, Trends Anal. Chem., 29, 1, 10.1016/j.trac.2009.10.003 · DOI · Paper page
- Plotka–Wasylka, 2015, Miniaturized solid–phase extraction techniques, Trends Anal. Chem., 73, 19, 10.1016/j.trac.2015.04.026 · DOI · Paper page
- Arthur, 1990, Solid phase microextraction with thermal desorption using fused silica optical fibers, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
- He, 1997, Liquid–phase microextraction in a single drop of organic solvent by using a conventional microsyringe, Anal. Chem., 69, 4634, 10.1021/ac970242q · DOI · Paper page
- Theis, 2001, Headspace solvent microextraction, Anal. Chem., 73, 5651, 10.1021/ac015569c · DOI · Paper page
- Shen, 2003, Headspace liquid–phase microextraction of chlorobenzenes in soil with gas chromatography–electron capture detection, Anal. Chem., 75, 98, 10.1021/ac020428b · DOI · Paper page
- Jain, 2011, Recent advances in applications of single–drop microextraction: a review, Anal. Chim. Acta, 706, 37, 10.1016/j.aca.2011.08.022 · DOI · Paper page
- Tang, 2018, Single–drop microextraction, Trends Anal. Chem., 108, 306, 10.1016/j.trac.2018.09.016 · DOI · Paper page
- Kocurova, 2013, A glance at achievements in the coupling of headspace and direct immersion single–drop microextraction with chromatographic techniques, J. Sep. Sci., 36, 3758, 10.1002/jssc.201300575 · DOI · Paper page
- Andruch, 2012, Recent advances in coupling single–drop and dispersive liquid–liquid microextraction with UV–vis spectrophotometry and related detection techniques, Microchem. J., 102, 1, 10.1016/j.microc.2011.10.006 · DOI
- Jiang, 2005, Dynamic hollow fiber–supported headspace liquid–phase microextraction, J. Chromatogr. A, 1087, 289, 10.1016/j.chroma.2005.06.010 · DOI
- Cabaleiro, 2014, Coumarins as turn on/off fluorescent probes for detection of residual acetone in cosmetics following headspace single–drop microextraction, Talanta, 129, 113, 10.1016/j.talanta.2014.05.033 · DOI
- Khalili Zanjani, 2006, Analysis of n–alkanes in water samples by means of headspace solvent microextraction and gas chromatography, J. Hazard Mater., 136, 714, 10.1016/j.jhazmat.2006.01.004 · doi:10.1016/j.jhazmat.2006.01.004
- Shamsipur, 2008, Headspace solvent microextraction–gas chromatographic thermionic specific detector determination of amitraz in honey after hydrolysis to 2,4–dimethylaniline, J. Food Compos. Anal., 21, 264, 10.1016/j.jfca.2007.10.004 · doi:10.1016/j.jfca.2007.10.004
- Pranaitytė, 2007, Capillary electrophoretic determination of ammonia using headspace single–drop microextraction, Microchem. J., 86, 48, 10.1016/j.microc.2006.10.001 · DOI
- He, 2006, Single drop liquid–liquid–liquid microextraction of methamphetamine and amphetamine in urine, J. Chromatogr. A, 1133, 35, 10.1016/j.chroma.2006.08.047 · DOI
- Przyjazny, 2002, Analytical characteristics of the determination of benzene, toluene, ethylbenzene and xylenes in water by headspace solvent microextraction, J. Chromatogr. A, 977, 143, 10.1016/S0021-9673(02)01422-X · DOI · Paper page
- Xiao, 2008, Speciation of butyltin compounds in environmental and biological samples using headspace single drop microextraction coupled with gas chromatography–inductively coupled plasma–mass spectrometry, J. Chromatogr. A, 1211, 135, 10.1016/j.chroma.2008.09.089 · DOI
- Pillai, 2010, Headspace single–drop microextraction and fibre optics–based cuvetteless micro–spectrophotometry for the determination of chloride involving oxidation with permanganate, Talanta, 80, 1816, 10.1016/j.talanta.2009.10.027 · DOI
- Jain, 2010, Headspace single–drop microextraction and cuvetteless microspectrophotometry for the selective determination of free and total cyanide involving reaction with ninhydrin, Talanta, 82, 758, 10.1016/j.talanta.2010.05.048 · DOI
- Tor, 2006, Determination of chlorobenzenes in water by drop–based liquid–phase microextraction and gas chromatography–electron capture detection, J. Chromatogr. A, 1125, 129, 10.1016/j.chroma.2006.06.081 · DOI
- Yiping, 2010, Ion chromatography for rapid and sensitive determination of fluoride in milk after headspace single–drop microextraction with in situ generation of volatile hydrogen fluoride, Anal. Chim. Acta, 661, 161, 10.1016/j.aca.2009.12.018 · DOI
- Pena Pereira, 2007, Headspace single drop microextraction of methylcyclopentadienyl–manganese tricarbonyl from water samples followed by gas chromatography–mass spectrometry, Talanta, 74, 47, 10.1016/j.talanta.2007.05.024 · DOI
- Shahdousti, 2007, Determination of valproic acid in human serum and pharmaceutical preparations by headspace liquid–phase microextraction gas chromatography–flame ionization detection without prior derivatization, J. Chromatogr. B, 850, 128, 10.1016/j.jchromb.2006.11.013 · DOI
- Rincón, 2011, Headspace–single drop microextraction (HS–SDME) in combination with high–performance liquid chromatography (HPLC) to evaluate the content of alkyl– and methoxy–phenolic compounds in biomass smoke, Talanta, 85, 1265, 10.1016/j.talanta.2011.05.046 · DOI
- García–Figueroa, 2017, Headspace single–drop microextraction coupled with microvolume fluorospectrometry for highly sensitive determination of bromide, Talanta, 170, 9, 10.1016/j.talanta.2017.03.090 · DOI
- Gil, 2005, Determination of methylmercury by electrothermal atomic absorption spectrometry using headspace single–drop microextraction with in situ hydride generation, Spectrochim. Acta B, 60, 145, 10.1016/j.sab.2004.10.008 · DOI
- Ebrahimzadeh, 2007, Application of headspace solvent microextraction to the analysis of mononitrotoluenes in waste water samples, Talanta, 72, 193, 10.1016/j.talanta.2006.10.014 · DOI
- Xiao, 2006, Optimization of a single–drop microextraction procedure for the determination of organophosphorus pesticides in water and fruit juice with gas chromatography–flame photometric detection, Talanta, 69, 848, 10.1016/j.talanta.2005.11.024 · DOI · Paper page
- Shariati–Feizabadi, 2003, Headspace solvent microextraction and gas chromatographic determination of some polycyclic aromatic hydrocarbons in water samples, Anal. Chim. Acta, 489, 21, 10.1016/S0003-2670(03)00709-8 · DOI
- Fragueiro, 2006, Hydride generation–headspace single–drop microextraction–electrothermal atomic absorption spectrometry method for determination of selenium in waters after photoassisted prereduction, Talanta, 68, 1096, 10.1016/j.talanta.2005.07.011 · DOI
- Li, 2010, Application of headspace single–drop microextraction coupled with gas chromatography for the determination of short–chain fatty acids in RuO4 oxidation products of asphaltenes, J. Chromatogr. A, 1217, 3561, 10.1016/j.chroma.2010.03.041 · DOI
- Dong, 2006, Development of gas chromatography–mass spectrometry following headspace single–drop microextraction and simultaneous derivatization for fast determination of the diabetes biomarker, acetone in human blood samples, Anal. Chim. Acta, 569, 91, 10.1016/j.aca.2006.03.095 · DOI
- Deng, 2006, Development of gas chromatography–mass spectrometry following headspace single–drop microextraction and simultaneous derivatization for fast determination of short–chain aliphatic amines in water samples, J. Chromatogr. A, 1131, 45, 10.1016/j.chroma.2006.07.084 · DOI
- Fiamegos, 2008, Gas chromatographic determination of carbonyl compounds in biological and oil samples by headspace single–drop microextraction with in–drop derivatization, Anal. Chim. Acta, 609, 175, 10.1016/j.aca.2007.12.042 · DOI
- Chiang, 2008, Simultaneous derivatization and extraction of amphetamine and methylenedioxyamphetamine in urine with headspace liquid–phase microextraction followed by gas chromatography–mass spectrometry, J. Chromatogr. A, 1185, 19, 10.1016/j.chroma.2008.01.038 · DOI
- Li, 2005, Gas chromatography–mass spectrometric analysis of hexanal and heptanal in human blood by headspace single–drop microextraction with droplet derivatization, Anal. Biochem., 342, 318, 10.1016/j.ab.2005.04.024 · DOI
- Saraji, 2009, Single–drop microextraction with in–micro vial derivatization for the determination of haloacetic acids in water sample by gas chromatography–mass spectrometry, J. Chromatogr. A, 1216, 1059, 10.1016/j.chroma.2008.12.064 · DOI
- Liu, 2003, Use of ionic liquids for liquid–phase microextraction of polycyclic aromatic hydrocarbons, Anal. Chem., 75, 5870, 10.1021/ac034506m · DOI · Paper page
- Peng, 2005, Ionic liquid for high temperature headspace liquid–phase microextraction of chlorinated anilines in environmental water samples, J. Chromatogr. A, 1072, 3, 10.1016/j.chroma.2004.11.060 · DOI
- Fernández, 2018, Hydrophilic magnetic ionic liquid for magnetic headspace single–drop microextraction of chlorobenzenes prior to thermal desorption–gas chromatography–mass spectrometry, Anal. Bioanal. Chem., 410, 4679, 10.1007/s00216-017-0755-2 · DOI
- Jeannot, 2010, Single drop microextraction–development, applications and future trends, J. Chromatogr. A, 1217, 2326, 10.1016/j.chroma.2009.10.089 · DOI · Paper page
- Pakade, 2010, Development and applications of single–drop microextraction for pesticide residue analysis: a review, J. Separ. Sci., 33, 3683, 10.1002/jssc.201000331 · DOI · Paper page
- Vidal, 2007, Microwave–assisted headspace single–drop microextration of chlorobenzenes from water samples, Anal. Chim. Acta, 592, 9, 10.1016/j.aca.2007.03.066 · DOI
- Xu, 2007, Development of a novel ultrasound–assisted headspace liquid–phase microextraction and its application to the analysis of chlorophenols in real aqueous samples, J. Chromatogr. A, 1167, 1, 10.1016/j.chroma.2007.08.022 · DOI
- Wang, 2009, Ultrasonic nebulization extraction coupled with headspace single drop microextraction and gas chromatography–mass spectrometry for analysis of the essential oil in Cuminum cyminum L, Anal. Chim. Acta, 647, 72, 10.1016/j.aca.2009.05.030 · DOI
- Huang, 2007, Determination of organochlorine pesticides in water using solvent cooling assisted dynamic hollow–fiber–supported headspace liquid–phase microextraction, J. Chromatogr. A, 1176, 19, 10.1016/j.chroma.2007.10.073 · DOI
- Taghizadeh, 2012, Determination of residual monomers in latex by headspace hollow fiber protected liquid–phase microextraction combined with high–performance liquid chromatography, Polym. Test., 31, 297, 10.1016/j.polymertesting.2011.11.001 · DOI
- Chen, 2015, Determination of volatile organic compounds in water using headspace knotted hollow fiber microextraction, J. Chromatogr. A, 1395, 41, 10.1016/j.chroma.2015.03.067 · DOI
- Meng, 2009, Simultaneous derivatization and extraction of free cyanide in biological samples with home–made hollow fiber–protected headspace liquid–phase microextraction followed by capillary electrophoresis with UV detection, J. Chromatogr. B, 877, 3645, 10.1016/j.jchromb.2009.09.006 · DOI
- Ye, 2007, Improved single–drop microextraction for high sensitive analysis, J. Chromatogr. A, 1139, 7, 10.1016/j.chroma.2006.10.089 · DOI
- Sharma, 2011, Solid–phase extraction combined with headspace single–drop microextraction of chlorophenols as their methyl ethers and analysis by high–performance liquid chromatography–diode array detection, Talanta, 83, 994, 10.1016/j.talanta.2010.11.003 · DOI
- Batlle, 2008, Active single–drop microextraction for the determination of gaseous diisocyanates, J. Chromatogr. A, 1185, 155, 10.1016/j.chroma.2008.01.053 · DOI
- Qian, 2006, Funnelform single–drop microextraction for gas chromatography–electron–capture detection, J. Chromatogr. A, 1134, 32, 10.1016/j.chroma.2006.08.094 · DOI
- Zaruba, 2016, Using an optical probe as the microdrop holder in headspace single drop microextraction: determination of sulfite in food samples, Anal. Chem., 88, 10296, 10.1021/acs.analchem.6b03129 · DOI · Paper page
- Farajzadeh, 2016, Development of dynamic headspace–liquid phase microextraction method performed in a home–made extraction vessel for extraction and preconcentration of 1,4–dioxane from shampoo, J. Iran. Chem. Soc., 13, 1385
- Farajzadeh, 2016, Development of a new dynamic headspace liquid–phase microextraction method, Chromatographia, 79, 773, 10.1007/s10337-016-3095-z · DOI
- Farajzadeh, 2017, Determination of pyridine as a decomposition product in ceftazidime and mouthwash solution, Chromatographia, 80, 497, 10.1007/s10337-017-3241-2 · DOI
- Farajzadeh, 2017, Extraction and preconcentration of residual solvents in pharmaceuticals using dynamic headspace–liquid phase microextraction and their determination by gas chromatography–flame ionization detection, Biomed. Chromatogr., 31, e3788, 10.1002/bmc.3788 · doi:10.1002/bmc.3788
- Nechaeva, 2018, A paper–based analytical device for the determination of hydrogen sulfide in fuel oils based on headspace liquid–phase microextraction and cyclic voltammetry, Talanta, 183, 290, 10.1016/j.talanta.2018.02.074 · DOI
- Liu, 1995, Liquid droplet. A renewable gas sampling interface, Anal. Chem., 67, 2042, 10.1021/ac00109a023 · DOI · Paper page
- Liu, 1996, Analytical chemistry in a drop, Trends Anal. Chem., 15, 468, 10.1016/S0165-9936(96)00065-9 · DOI
- Liu, 1997, A Liquid Drop: what is it good for?, Microchem. J., 57, 127, 10.1006/mchj.1997.1498 · DOI
- Mohammadi, 2006, Automated dynamic headspace organic solvent film microextraction for benzene, toluene, ethylbenzene and xylene: renewable liquid film as a sampler by a programmable motor, J. Chromatogr. A, 1107, 19, 10.1016/j.chroma.2005.12.054 · doi:10.1016/j.chroma.2005.12.054
- Vallecillos, 2012, Fully automated ionic liquid–based headspace single drop microextraction coupled to GC–MS/MS to determine musk fragrances in environmental water samples, Talanta, 99, 824, 10.1016/j.talanta.2012.07.036 · DOI
- Li, 2014, Comparison of fully–automated headspace single drop microextraction and headspace solid phase microextraction techniques for rapid analysis of No. 6 solvent residues in edible oil, Microchem. J., 117, 187, 10.1016/j.microc.2014.07.004 · DOI
Cited by
Chen, J., Li, X., Huang, A., Deng, W., & Xiao, Y. (2021) · Food Chemistry · doi:10.1016/j.foodchem.2021.130373 · Cited by 51
Mehravar, A., Feizbakhsh, A., Sarafi, A. H. M., Konoz, E., & Faraji, H. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461618 · Cited by 46
Zhao, W., Jing, X., Tian, Y., & Feng, C. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105416 · Cited by 43
Saei, A., Javadi, A., Mogaddam, M. R. A., Mirzaei, H., & Nemati, M. (2022) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067319.2020.1759564 · Cited by 22
Self-citationMogaddam, M. R. A., Farajzadeh, M. A., Nemati, M., Mohebbi, A., & Khodadadeian, F. (2022) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067319.2020.1784886 · Cited by 3
Self-citation
Metadata
- Authors
- Afshar Mogaddam, M. R., Mohebbi, A., Pazhohan, A., Khodadadeian, F., & Farajzadeh, M. A.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 110
- Pages
- 8-14
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2899222706
- Cited by
- 89
- References
- 5
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Funders
- Research Council of Tabriz University
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.