Modeling Glucose Transport From Systemic Circulation to Sweat

La Count, Terri D., Jajack, Andrew, Heikenfeld, Jason, Kasting, Gerald B.·2019·Journal of Pharmaceutical Sciences

Abstract

Sweat sensing may provide a noninvasive means of estimating blood biomarker levels if a number of technological hurdles can be overcome. This report describes progress on a physiologically based transport model relating sweat glucose and key electrolyte concentrations to those in blood. Iontophoretically stimulated sweat glucose and fasted blood glucose were simultaneously measured in 2 healthy human subjects. Sweat glucose was measured with a novel, prototype skin sweat collection/analysis system and blood glucose with a commercial fingerstick glucometer. These data, in combination with data from 3 published studies, were used to calibrate a dynamic mathematical model for glucose transport and uptake in human skin, followed by extraction into sweat. Model simulations revealed that experimental and literature sweat glucose values were well represented under varying physiologic conditions. The glucose model, calibrated under a variety of experimental conditions including electrical enhancement, revealed a 10 min blood-to-sweat lag time and a sweat/blood glucose level ranging from 0.001 to 0.02, depending on the sweat rate. These values are consistent with those reported in the literature. The developed model satisfactorily described the sweat-to-blood relationship for glucose concentrations measured under different conditions in 4 human studies including the present pilot study. The algorithm may be used to facilitate sweat biosensor development.

Integrity signals

Registry

Crossref · 10.1016/j.xphs.2018.09.026

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • La Count et al.'s glucose model demonstrated a ten-minute blood-to-sweat lag time and a sweat/blood glucose level ranging from 0.001 to 0.02, depending on the sweat rate.

    “The glucose model, calibrated under a variety of experimental conditions including electrical enhancement, demonstrated a ten-minute blood-to-sweat lag time and a sweat/blood glucose level ranging from 0.001 to 0.02, depending on the sweat rate.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
La Count, T. D., Jajack, A., Heikenfeld, J., & Kasting, G. B.
Affiliations
University of Cincinnati (US)
Corresponding author
Kasting, Gerald B.
Venue
Journal of Pharmaceutical Sciences
Publisher
Elsevier BV
Published
2019-01
Volume
108
Issue
1
Pages
364-371
ISSN
0022-3549 (ISSN-L)
OpenAlex
W2894030212
Cited by
60
References
37
Citations by year
2026: 5 · 2025: 8 · 2024: 16 · 2023: 11 · 2022: 9 · 2021: 4 · 2020: 5 · 2019: 2
FWCI
1.29
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Pharmaceutical Sciences (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Foundation (1608275)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
sweat glucose, blood glucose, glucose transport, skin, iontophoresis, non-invasive glucose monitoring, sweat electrolytes, sweat rate
MeSH terms
Adult, Biological Transport, Blood Glucose, Calibration, Electrolytes, Female, Glucose, Humans, Male, Skin, Sweat, Glucose Transport Proteins, Facilitative, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review