Mass spectrometry-enabled structural biology of membrane proteins
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The last ∼25 years has seen mass spectrometry (MS) emerge as an integral method in the structural biology toolkit. In particular, MS has enabled the structural characterization of proteins and protein assemblies that have been intractable by other methods, especially those that are large, heterogeneous or transient, providing experimental evidence for their structural organization in support of, and in advance of, high resolution methods. The most recent frontier conquered in the field of MS-based structural biology has been the application of established methods for studying water soluble proteins to the more challenging targets of integral membrane proteins. The power of MS in obtaining structural information has been enabled by advances in instrumentation and the development of hyphenated mass spectrometry-based methods, such as ion mobility spectrometry-MS, chemical crosslinking-MS and other chemical labelling/footprinting-MS methods. In this review we detail the insights garnered into the structural biology of membrane proteins by applying such techniques. Application and refinement of these methods has yielded unprecedented insights in many areas, including membrane protein conformation, dynamics, lipid/ligand binding, and conformational perturbations due to ligand binding, which can be challenging to study using other methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How many drug targets are there?
Overington, J. P., Al-Lazikani, B., & Hopkins, A. L. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2199 · Cited by 3,505
Hopkins, A. L., & Groom, C. R. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd892 · Cited by 3,305
The structure and function of G-protein-coupled receptors
Rosenbaum, D. M., Rasmussen, S. G. F., & Kobilka, B. K. (2009) · Nature · doi:10.1038/nature08144 · Cited by 2,534
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Kühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000 · cited 1×
“These spectra are complex, due to the heterogeneity of the MP-lipid complexes observed (MPs with 0 to 120 bound lipids were copopulated), and require deconvolution algorithms to assign the complex series of overlapping peaks [116].”
BackgroundElectrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901 · cited 1×
“This approach allows protein subunit stoichiometry and architecture to be studied (the latter when coupled with ion mobility spectrometry, IMS) [33,37].”
BackgroundNative Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602 · cited 2×
“Radford, Methods (2018 interactions, and thus (some aspects of) tertiary and quaternary structure [36].”
BackgroundAngel, T. E., Chance, M. R., & Palczewski, K. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903545106 · Cited by 235 · cited 1×
“This method also has the advantage of being able to study ordered water molecules in protein structures [225,226].”
Method
Cited by
Piersimoni, L., Kastritis, P. L., Arlt, C., & Sinz, A. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00786 · Cited by 314
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
Native Mass Spectrometry of Membrane Proteins
Keener, J. E., Zhang, G., & Marty, M. T. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04342 · Cited by 126
Ion Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107
Sipe, S. N., Patrick, J. W., Laganowsky, A., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03689 · Cited by 39
Allison, T. M., Barran, P., Cianférani, S., Degiacomi, M. T., Gabelica, V., Grandori, R., Marklund, E. G., Menneteau, T., Migas, L. G., Politis, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05791 · Cited by 38
Metadata
- Authors
- Calabrese, A. N., & Radford, S. E.
- Venue
- Methods
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 147
- Pages
- 187-205
- ISSN
- 1046-2023 (ISSN-L)
- OpenAlex
- W2788851210
- Cited by
- 92
- References
- 18
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.