The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Detection of endothelial dysfunction with brachial artery ultrasound scanning
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Furchgott, R. F., & Zawadzki, J. V. (1980) · Nature · doi:10.1038/288373a0 · Cited by 12,064
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
Endothelial dysfunction in cardiovascular diseases: the role of oxidant stress
Cai, H., & Harrison, D. G. (2000) · Circulation Research · doi:10.1161/01.res.87.10.840 · Cited by 3,839
Activation of nitric oxide synthase in endothelial cells by Akt-dependent phosphorylation
Dimmeler, S., Fleming, I., Fisslthaler, B., Hermann, C., Busse, R., & Zeiher, A. M. (1999) · Nature · doi:10.1038/21224 · Cited by 3,591
Close Relation of Endothelial Function in the Human Coronary and Peripheral Circulations
Anderson, T. J., Uehata, A., Gerhard, M. D., Meredith, I. T., Knab, S., Delagrange, D., Lieberman, E. H., Ganz, P., Creager, M. A., Yeung, A. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00327-4 · Cited by 2,033
Gokce, N., Keaney, J. F., Frei, B., Holbrook, M., Olesiak, M., Zachariah, B. J., Leeuwenburgh, C., Heinecke, J. W., & Vita, J. A. (1999) · Circulation · doi:10.1161/01.cir.99.25.3234 · Cited by 387
Measurement of endothelial function by brachial artery flow-mediated vasodilation
Vogel, R. A. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01764-7 · Cited by 133
Etsuda, H., Takase, B., Kusano, H., Hamabe, A., Kuhara, R., Akima, T., Matsushima, Y., Arakawa, K., Satomura, K., Ohsuzu, F., et al. (1999) · Clinical Cardiology · doi:10.1002/clc.4960220610 · Cited by 124
Cited by
The role of virgin olive oil components in the modulation of endothelial function
Perona, J. S., Cabello-Moruno, R., & Ruiz-Gutierrez, V. (2006) · The Journal of Nutritional Biochemistry · doi:10.1016/j.jnutbio.2005.11.007 · Cited by 274
Narita, K., Murata, T., Hamada, T., Takahashi, T., Omori, M., Suganuma, N., Yoshida, H., & Wada, Y. (2007) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2006.01.003 · Cited by 100
Holtfreter, B., Empen, K., Gläser, S., Lorbeer, R., Völzke, H., Ewert, R., Kocher, T., & Dörr, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0084603 · Cited by 79
González-Rámila, S., Sarriá, B., Seguido, M. A., García-Cordero, J., Mateos, R., & Bravo, L. (2022) · European Journal of Nutrition · doi:10.1007/s00394-022-03001-y · Cited by 24
“Flow mediated dilatation (FMD) is a non-invasive measurement of vasodilation and it is considered an index of NO bioavailability [42].”
Background
Metadata
- Authors
- Faulx, M. D., Wright, A. T., & Hoit, B. D.
- Venue
- American Heart Journal
- Publisher
- Elsevier BV
- Published
- 2003-06
- Volume
- 145
- Issue
- 6
- Pages
- 943-951
- ISSN
- 0002-8703 (ISSN-L)
- OpenAlex
- W2156971098
- Cited by
- 202
- References
- 8
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of endothelial dysfunction with brachial artery ultrasound scanning. https://app.cochat.ai/papers/10.1016/s0002-8703(03)00097-8
- The paper
- Faulx, M. D., Wright, A. T., & Hoit, B. D. (2003). Detection of endothelial dysfunction with brachial artery ultrasound scanning. American Heart Journal. https://doi.org/10.1016/s0002-8703(03)00097-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.