Receiver-operator characteristic curves for the ultrasonographic prediction of small-for-gestational-age fetuses in low-risk pregnancies
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Objective Our purpose was to assess the accuracy of third-trimester ultrasonographic biometry in the diagnosis of small-for-gestational-age fetuses in a low-risk obstetric population. Study design A total of 1000 low-risk pregnancies were prospectively examined at 31 weeks' gestation. The diagnostic accuracy of the fetal abdominal circumference and estimated fetal weight according to 24 formulas in the literature were evaluated by the use of receiver-operator characteristic curves. Results The incidence of a birth weight Conclusion In a low-risk obstetric population third-trimester ultrasonographic biometry has limited value in predicting small-for-gestational-age fetuses, and estimation of fetal weight does not carry an advantage over measurement of the abdominal circumference. The optimal cutoff value remains uncertain. However, by accepting a 10% false-positive rate, half of small-for-gestational-age fetuses and most perinatal complications could be recognized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Evidence supports the use of AC as a diagnostic criterion for FGR.”
From Society for Maternal-Fetal Medicine Consult Series #52: Diagnosis and management of fetal growth restriction (2020) · cites this paper as [31]
In the citing paper
“In a prospective study in 1000 low-risk pregnancies, an AC of less than the 10th percentile was found to have diagnostic accuracy similar to EFW less than the 10th percentile for the prediction of SGA. 31”
From Society for Maternal-Fetal Medicine Consult Series #52: Diagnosis and management of fetal growth restriction (2020) · cites this paper as [31]
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
Hadlock, F. P., Harrist, R. B., Carpenter, R. J., Deter, R. L., & Park, S. K. (1984) · Radiology · doi:10.1148/radiology.150.2.6691115 · Cited by 785
MacLennan, R., & Jensen, O. M. (1977) · PubMed · Cited by 685
An evaluation of two equations for predicting fetal weight by ultrasound
Shepard, M. J., Richards, V. A., Berkowitz, R. L., Warsof, S. L., & Hobbins, J. C. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)32283-9 · Cited by 607
Effect of Prenatal Ultrasound Screening on Perinatal Outcome
Ewigman, B. G., Crane, J. P., Frigoletto, F. D., LeFevre, M. L., Bain, R. P., & McNellis, D. (1993) · New England Journal of Medicine · doi:10.1056/nejm199309163291201 · Cited by 600
ULTRASONIC MEASUREMENT OF FETAL ABDOMEN CIRCUMFERENCE IN THE ESTIMATION OF FETAL WEIGHT
Campbell, S., & Wilkin, D. (1975) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1975.tb00708.x · Cited by 542
Fetal biometry at 14–40 weeks' gestation
Snijders, R. J. M., & Nicolaides, K. H. (1994) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1994.04010034.x · Cited by 501
The estimation of fetal weight by computer-assisted analysis
Warsof, S. L., Gohari, P., Berkowitz, R. L., & Hobbins, J. C. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90058-8 · Cited by 355
Effect of Prenatal Ultrasound Screening on Perinatal Outcome
Ewigman, B. G., Crane, J. P., Frigoletto, F. D., LeFevre, M. L., Bain, R. P., & McNellis, D. (1994) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-199402000-00005 · Cited by 323
Charts of fetal size: 3. Abdominal measurements
Chitty, L. S., Altman, D. G., Henderson, A., & Campbell, S. (1994) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13077.x · Cited by 272
RANDOMISED CONTROLLED TRIAL OF ULTRASONOGRAPHIC SCREENING IN PREGNANCY
Bakketeig, L., Jacobsen, G., Brodtkorb, C., Eriksen, B., Eik-Nes, S., Ulstein, M., Balstad, P., & Jörgensen, N. (1984) · The Lancet · doi:10.1016/s0140-6736(84)90492-6 · Cited by 193
Fetal abdominal circumference as a predictor of menstrual age
Hadlock, F., Deter, R., Harrist, R., & Park, S. (1982) · American Journal of Roentgenology · doi:10.2214/ajr.139.2.367 · Cited by 180
Design and analysis of studies to derive charts of fetal size
Altman, D. G., & Chitty, L. S. (1993) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1993.03060378.x · Cited by 163
Prediction of the small for gestational age infant: which ultrasonic measurement is best?
Chang, T. C., Robson, S. C., Boys, R. J., & Spencer, J. A. D. (1992) · PubMed · Cited by 144
Fetal weight estimation formulas with head, abdominal, femur, and thigh circumference measurements
Vintzileos, A. M., Campbell, W. A., Rodis, J. F., Bors-Koefoed, R., & NOCHIMSON, D. J. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(87)80182-5 · Cited by 110
Woo, J. S., Wan, C. W., & Cho, K. M. (1985) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1985.4.2.65 · Cited by 81
Larsen, T., Larsen, J. F., Petersen, S., & Greisen, G. O. (1992) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1992.tb13783.x · Cited by 78
Estimation of fetal weight by ultrasound
Jordaan, H. V. F. (1983) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870110202 · Cited by 74
Thurnau, G. R., Tamura, R. K., Sabbagha, R. E., Depp, O. R., Dyer, A. R., Larkin, R., Lee, T. J., & Laughlin, C. L. (1983) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(83)91195-x · Cited by 73
Ultrasonic fetal weight prediction: role of head circumference and femur length.
Weiner, C. P., Sabbagha, R. E., Vaisrub, N., & Socol, M. L. (1985) · PubMed · Cited by 61
Deter, R. L., Harrist, R. B., Hadlock, F. P., & Carpenter, R. J. (1982) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870100804 · Cited by 57
Accurate Ultrasonic Estimation of Fetal Weight
Ott, W., Doyle, S., Flamm, S., & Wittman, J. (1986) · American Journal of Perinatology · doi:10.1055/s-2007-999885 · Cited by 55
Estimating fetal weights less than 2000 g: an accurate and simple method
Weinberger, E., Cyr, D., Hirsch, J., Richardson, T., Hanson, J., & Mack, L. A. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.5.973 · Cited by 21
“Fetal Growth Charts”: Comparison of Cross-Sectional Ultrasound Examinations with Birth Weight
Bernstein, I. M., Meyer, M. C., & Capeless, E. L. (1994) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767059409017271 · Cited by 21
Aphthoid ulcerations in ileocolic candidiasis
Rk, G.-M. (1983) · American Journal of Roentgenology · doi:10.2214/ajr.141.5.973 · Cited by 7
Research works printed but not linked: 2
- 1980, Gruppo di Lavoro della Ricerca Policentrica Longitudinale ostetrico-pediatrica: standard del peso del neonato italiano, Riv Ital Pediatr, 6, 153
- Nicolini, 1986, Curve trasversali dell' accrescimento fetale, Minerva Ginecol, 38, 873
Cited by
Martins, J. G., Biggio, J. R., & Abuhamad, A. (2020) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.05.010 · Cited by 584
Intrauterine growth restriction: new concepts in antenatal surveillance, diagnosis, and management
Figueras, F., & Gardosi, J. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.08.055 · Cited by 485
Sonographic EFW and macrosomia: Is there an optimum formula to predict diabetic fetal macrosomia?
Combs, C. A., Rosenn, B., Miodovnik, M., & Siddiqi, T. A. (2000) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1002/(sici)1520-6661(200001/02)9:1<55::aid-mfm12>3.0.co;2-9 · Cited by 137
Ciobanu, A., Rouvali, A., Syngelaki, A., Akolekar, R., & Nicolaides, K. H. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2019.01.227 · Cited by 115
Impaired growth and risk of fetal death: Is the tenth percentile the appropriate standard?
Seeds, J. W., & Peng, T. (1998) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(98)70475-2 · Cited by 115
Metadata
- Authors
- David, C., Tagliavini, G., Pilu, G., Rudenholz, A., & Bovicelli, L.
- Affiliations
- University of Bologna (IT)
- ORCID
- Pilu, Gianluigi
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 1996-03
- Volume
- 174
- Issue
- 3
- Pages
- 1037-1042
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W2088678062
- Semantic Scholar
- 44f74d4e7b28d2de87624e88dd861ccd8a05ddd5
- Cited by
- 62
- References
- 26
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 4 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 3 · 2014: 4 · 2013: 5 · 2012: 3
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- American Journal of Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Keywords
- small-for-gestational-age fetuses, fetal growth restriction, fetal abdominal circumference, estimated fetal weight, diagnostic accuracy, low-risk pregnancy, perinatal outcomes, cut-off values
- MeSH terms
- Abdomen, Biometry, Birth Weight, Female, Gestational Age, Humans, Infant, Newborn, Infant, Small for Gestational Age, Predictive Value of Tests, Pregnancy, Pregnancy Outcome, Pregnancy Trimester, Third, Prospective Studies, Risk Factors, ROC Curve, Sensitivity and Specificity, Ultrasonography, Prenatal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.