Electrospray ionization of large multiply charged species proceeds via Dole’s charged residue mechanism
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The maximum charge zmax on a variety of electrospray ions of globular proteins retaining their native structure, as well as naturally compact starburst dendrimers is compared to the Rayleigh charge zR (based on a water sphere with the ion mass). For most published data examined, zmax is between 65% and 110% of zR, providing strong support in favor of Dole’s charged residue mechanism, at least for masses from 3.3 kD up to 1.4 MD. Other large but less compact ions from proteins and linear chains of polyethylene glycols (PEGs) have zmax values considerably larger than zR, apparently implying that they also form as charged residues, though from non-spherical drops held together by the polymer backbone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayleigh, L., & Nachtrieb, N. H. (1957) · Physics Today · doi:10.1063/1.3060230 · Cited by 3,464
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Katta, V., Chait, B. T., & Carr, S. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050415 · Cited by 453
Rupley, J. A., Gratton, E., & Careri, G. (1983) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(83)90063-4 · Cited by 443
Protein Structure in Vacuo: Gas-Phase Conformations of BPTI and Cytochrome c
Shelimov, K. B., Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9619059 · Cited by 414
Multiple charging in electrospray ionization of poly(ethylene glycols)
Wong, S. F., Meng, C. K., & Fenn, J. B. (1988) · The Journal of Physical Chemistry · doi:10.1021/j100313a058 · Cited by 393
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Katta, V., & Chait, B. T. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00067a054 · Cited by 282
Konermann, L., & Douglas, D. J. (1997) · Biochemistry · doi:10.1021/bi971266u · Cited by 239
Valentine, S. J., Anderson, J. G., Ellington, A. D., & Clemmer, D. E. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp970217o · Cited by 234
Electrospray mass spectrometry of poly(ethylene glycols) with molecular weights up to five million
Nohmi, T., & Fenn, J. B. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00035a012 · Cited by 217
Experiments on the kinetics of field evaporation of small ions from droplets
Loscertales, I. G., & Fernández de la Mora, J. (1995) · The Journal of Chemical Physics · doi:10.1063/1.470591 · Cited by 183
Mechanisms of electrospray ionization of singly and multiply charged salt clusters
Gamero-Castaño, M., & de la Mora, J. F. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00596-6 · Cited by 162
Conformations and folding of lysozyme ions in vacuo.
Gross, D. S., Schnier, P. D., Rodriguez‐Cruz, S. E., Fagerquist, C. K., & Williams, E. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.7.3143 · Cited by 156
Differential mobility analysis of molecular ions and nanometer particles
de la Mora, J. F., de Juan, L., Eichler, T., & Rosell-Llompart, J. (1998) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00039-9 · Cited by 153
Cytochrome c Folding Kinetics Studied by Time-Resolved Electrospray Ionization Mass Spectrometry
Konermann, L., Collings, B. A., & Douglas, D. J. (1997) · Biochemistry · doi:10.1021/bi970046d · Cited by 121
Konermann, L., Rosell, F. I., Mauk, A. G., & Douglas, D. J. (1997) · Biochemistry · doi:10.1021/bi970353j · Cited by 121
Hudgins, R. R., Woenckhaus, J., & Jarrold, M. F. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00182-1 · Cited by 118
Pasa-Tolic, L., Anderson, G., Smith, R. D., Brothers, H. M., Spindler, R., & Tomalia, D. A. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00161-4 · Cited by 113
Labowsky, M. J., Fenn, J. B., & de la Mora, J. F. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00595-4 · Cited by 93
Wang, F., & Tang, X. (1996) · Biochemistry · doi:10.1021/bi9521304 · Cited by 92
Electrospray Ion Formation: Desorption Versus Desertion
Fenn, J. B., Rosell-Llompart, J., Nohmi, T., Shen, S., & Banks, F. (1996) · ACS symposium series · doi:10.1021/bk-1995-0619.ch003 · Cited by 21
Cited by
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
“Nevertheless, the surface tension of water (g1⁄4 73 10 3 (N/m); see Table 1) was used by Fernandez de la Mora in Equation (11) for the surface tension of the droplets. The surface tension of methanol g1⁄4 22.6 10 3 (N/m) is much smaller. However, it is expected that the evaporating droplets will lose methanol preferen…”
BackgroundMethodResultInfluentialUnraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655
Metadata
- Authors
- Fernandez de la Mora, J.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2000-02
- Volume
- 406
- Issue
- 1
- Pages
- 93-104
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2165192566
- Cited by
- 528
- References
- 26
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.