Electrospray ionization of large multiply charged species proceeds via Dole’s charged residue mechanism
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The maximum charge zmax on a variety of electrospray ions of globular proteins retaining their native structure, as well as naturally compact starburst dendrimers is compared to the Rayleigh charge zR (based on a water sphere with the ion mass). For most published data examined, zmax is between 65% and 110% of zR, providing strong support in favor of Dole’s charged residue mechanism, at least for masses from 3.3 kD up to 1.4 MD. Other large but less compact ions from proteins and linear chains of polyethylene glycols (PEGs) have zmax values considerably larger than zR, apparently implying that they also form as charged residues, though from non-spherical drops held together by the polymer backbone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayleigh, L., & Nachtrieb, N. H. (1957) · Physics Today · doi:10.1063/1.3060230 · Cited by 3,464
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Katta, V., Chait, B. T., & Carr, S. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050415 · Cited by 453
Rupley, J. A., Gratton, E., & Careri, G. (1983) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(83)90063-4 · Cited by 443
Protein Structure in Vacuo: Gas-Phase Conformations of BPTI and Cytochrome c
Shelimov, K. B., Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9619059 · Cited by 414
Multiple charging in electrospray ionization of poly(ethylene glycols)
Wong, S. F., Meng, C. K., & Fenn, J. B. (1988) · The Journal of Physical Chemistry · doi:10.1021/j100313a058 · Cited by 393
Cited by
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
“Nevertheless, the surface tension of water (g1⁄4 73 10 3 (N/m); see Table 1) was used by Fernandez de la Mora in Equation (11) for the surface tension of the droplets. The surface tension of methanol g1⁄4 22.6 10 3 (N/m) is much smaller. However, it is expected that the evaporating droplets will lose methanol preferen…”
BackgroundMethodResultInfluentialUnraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“This observation was rationalized by the fact that during the ESI process, assuming the charge residue model [60], only solvent exposed basic residues could pick up a charge/proton.”
MethodInvestigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Fundamentals of Traveling Wave Ion Mobility Spectrometry
Shvartsburg, A. A., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8016295 · Cited by 534
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
On the mechanisms by which the charged droplets produced by electrospray lead to gas phase ions
Kebarle, P., & Peschke, M. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00598-x · Cited by 352
Mechanism of Charging and Supercharging Molecules in Electrospray Ionization
Iavarone, A. T., & Williams, E. R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021202t · Cited by 324
Principles of Electrospray Ionization
Wilm, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009407 · Cited by 311
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Nguyen, H. P., & Schug, K. A. (2008) · Journal of Separation Science · doi:10.1002/jssc.200700630 · Cited by 275
Native ion mobility-mass spectrometry and related methods in structural biology
Konijnenberg, A., Butterer, A., & Sobott, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2012.11.013 · Cited by 245
“For larger ions such as proteins and peptides, the so-called charge residue model (CRM) has been proposed [17].”
BackgroundKonermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Collisional Cooling of Large Ions in Electrospray Mass Spectrometry
Chernushevich, I. V., & Thomson, B. A. (2004) · Analytical Chemistry · doi:10.1021/ac035406j · Cited by 235
Christofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
Gas-phase ions of solute species from charged droplets of solutions
Nguyen, S., & Fenn, J. B. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609969104 · Cited by 232
Tandem Mass Spectrometry Reveals the Quaternary Organization of Macromolecular Assemblies
Benesch, J. L. P., Aquilina, J. A., Ruotolo, B. T., Sobott, F., & Robinson, C. V. (2006) · Chemistry & Biology · doi:10.1016/j.chembiol.2006.04.006 · Cited by 222
“078 3 Om [8].”
Mass spectrometry of macromolecular assemblies: preservation and dissociation
Benesch, J. L., & Robinson, C. V. (2006) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2006.03.009 · Cited by 203
“The squareroot relationship between the average charge state and the mass of the protein [27] has been shown to extend to non-covalent complexes up to and larger than 1 MDa [12].”
BackgroundMass Spectrometry of Protein Complexes: From Origins to Applications
Mehmood, S., Allison, T. M., & Robinson, C. V. (2015) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040214-121732 · Cited by 199
“According to the CRM, a droplet carrying a single protein shrinks by evaporation and fission until the complete removal of solvent, with the droplet charge transferred concomitantly to the protein (Figure 1b) (36).”
BackgroundMethodStudying 18 MDa Virus Assemblies with Native Mass Spectrometry
Snijder, J., Rose, R. J., Veesler, D., Johnson, J. E., & Heck, A. J. R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201210197 · Cited by 193
Peschke, M., Verkerk, U. H., & Kebarle, P. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.05.005 · Cited by 184
“Because of the findings of de la Mora [ 8 ] in favor of CRM, the offspring containing the protein would be expected to be considerably bigger than the protein so that the droplet after shrinkage by evaporation comes close the Rayleigh charge, before all the solvent is gone.”
BackgroundCombined Charged Residue-Field Emission Model of Macromolecular Electrospray Ionization
Hogan, C. J., Carroll, J. A., Rohrs, H. W., Biswas, P., & Gross, M. L. (2009) · Analytical Chemistry · doi:10.1021/ac8016532 · Cited by 174
Electrospray Ion Beam Deposition of Clusters and Biomolecules
Rauschenbach, S., Stadler, F. L., Lunedei, E., Malinowski, N., Koltsov, S., Costantini, G., & Kern, K. (2006) · Small · doi:10.1002/smll.200500479 · Cited by 167
New reagents for increasing ESI multiple charging of proteins and protein complexes
Lomeli, S. H., Peng, I. X., Yin, S., Ogorzalek Loo, R. R., & Loo, J. A. (2010) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.09.014 · Cited by 162
“Supercharging, the increased ESI charging observed when m-NBA and other liquids are added to denatured protein solutions, has been attributed to the charged residue model (CRM) relationship linking the Rayleigh limit of droplet charge (zR) to surface tension (), droplet radius (R), the permittivity of vacuum (0), and…”
InfluentialResolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry
Pierson, E. E., Keifer, D. Z., Asokan, A., & Jarrold, M. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00883 · Cited by 152
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
From QCEIMS to QCxMS: A Tool to Routinely Calculate CID Mass Spectra Using Molecular Dynamics
Koopman, J., & Grimme, S. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00098 · Cited by 80
Unique insights to intrinsically disordered proteins provided by ion mobility mass spectrometry
Stuchfield, D., & Barran, P. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2018.01.007 · Cited by 72
Vimer, S., Ben-Nissan, G., Morgenstern, D., Kumar-Deshmukh, F., Polkinghorn, C., Quintyn, R. S., Vasil’ev, Y. V., Beckman, J. S., Elad, N., Wysocki, V. H., et al. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00080 · Cited by 63
Kitova, E. N., Kitov, P. I., Bundle, D. R., & Klassen, J. S. (2001) · Glycobiology · doi:10.1093/glycob/11.7.605 · Cited by 59
Standard Proteoforms and Their Complexes for Native Mass Spectrometry
Schachner, L. F., Ives, A. N., McGee, J. P., Melani, R. D., Kafader, J. O., Compton, P. D., Patrie, S. M., & Kelleher, N. L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02191-w · Cited by 48
“The technique utilizes Bnative^—or non-denaturing and non-reducing—buffer conditions during the electrospray ionization process which helps preserve the primary and quaternary compositions of proteins and their complexes for subsequent MS analysis [4, 5].”
Marie, A.-L., Dominguez-Vega, E., Saller, F., Plantier, J.-L., Urbain, R., Borgel, D., Tran, N. T., Somsen, G. W., & Taverna, M. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.016 · Cited by 26
Shepherd, D. A., Holmes, K., Rowlands, D. J., Stonehouse, N. J., & Ashcroft, A. E. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.07.028 · Cited by 25
“Using the formula of de la Mora (41), we expected the maximum number of charges a folded protein of this mass to carry in the gas phase would be 14þ, indicating that the lower charges (9þ to 12þ ions) are consistent with a compact conformation.”
MethodWang, X., Norgate, E., Dai, J., Benoit, F., Bristow, T., England, R. M., Kalapothakis, J. M. D., & Barran, P. E. (2025) · Nature Communications · doi:10.1038/s41467-025-59065-x · Cited by 7
Metadata
- Authors
- Fernandez de la Mora, J.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2000-02
- Volume
- 406
- Issue
- 1
- Pages
- 93-104
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2165192566
- Cited by
- 528
- References
- 26
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.