Focal Volume Optics and Experimental Artifacts in Confocal Fluorescence Correlation Spectroscopy
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Fluorescence correlation spectroscopy (FCS) can provide a wealth of information about biological and chemical systems on a broad range of time scales (<1 micros to >1 s). Numerical modeling of the FCS observation volume combined with measurements has revealed, however, that the standard assumption of a three-dimensional Gaussian FCS observation volume is not a valid approximation under many common measurement conditions. As a result, the FCS autocorrelation will contain significant, systematic artifacts that are most severe with confocal optics when using a large detector aperture and aperture-limited illumination. These optical artifacts manifest themselves in the fluorescence correlation as an apparent additional exponential component or diffusing species with significant (>30%) amplitude that can imply extraneous kinetics, shift the measured diffusion time by as much as approximately 80%, and cause the axial ratio to diverge. Artifacts can be minimized or virtually eliminated by using a small confocal detector aperture, underfilled objective back-aperture, or two-photon excitation. However, using a detector aperture that is smaller or larger than the optimal value (approximately 4.5 optical units) greatly reduces both the count rate per molecule and the signal-to-noise ratio. Thus, there is a tradeoff between optimizing signal-to-noise and reducing experimental artifacts in one-photon FCS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Richards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095 · cited 2×
“To attempt to improve upon current FCS methodology we use a more sophisticated description of the focal volume (Wolf, 1959; Richards and Wolf, 1959), which treats the polarization of the excitation and is well-suited to high-NA optics.”
MethodInfluentialThermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Self-citationTopics in Fluorescence Spectroscopy
(2003) · Topics in Fluorescence Spectroscopy · doi:10.1007/0-306-47947-8 · Cited by 1,578
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Self-citationFluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Rigler, R., Mets, �., Widengren, J., & Kask, P. (1993) · European Biophysics Journal · doi:10.1007/bf00185777 · Cited by 1,002
Sorting single molecules: application to diagnostics and evolutionary biotechnology.
Eigen, M., & Rigler, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.13.5740 · Cited by 956
Electromagnetic diffraction in optical systems - I. An integral representation of the image field
Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0199 · Cited by 789
Cited by
Valence and patterning of aromatic residues determine the phase behavior of prion-like domains
Martin, E. W., Holehouse, A. S., Peran, I., Farag, M., Incicco, J. J., Bremer, A., Grace, C. R., Soranno, A., Pappu, R. V., & Mittag, T. (2020) · Science · doi:10.1126/science.aaw8653 · Cited by 1,147
Anomalous Subdiffusion Is a Measure for Cytoplasmic Crowding in Living Cells
Weiss, M., Elsner, M., Kartberg, F., & Nilsson, T. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.044263 · Cited by 756
Fluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
Fluorescence Correlation Spectroscopy: Novel Variations of an Established Technique
Haustein, E., & Schwille, P. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132612 · Cited by 548
Effect of Sodium Chloride on a Lipid Bilayer
Böckmann, R. A., Hac, A., Heimburg, T., & Grubmüller, H. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74594-9 · Cited by 545
Precise Measurement of Diffusion Coefficients using Scanning Fluorescence Correlation Spectroscopy
Petrášek, Z., & Schwille, P. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.108811 · Cited by 493
Fluorescence correlation spectroscopy in living cells
Kim, S. A., Heinze, K. G., & Schwille, P. (2007) · Nature Methods · doi:10.1038/nmeth1104 · Cited by 444
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Dertinger, T., Pacheco, V., von der Hocht, I., Hartmann, R., Gregor, I., & Enderlein, J. (2007) · ChemPhysChem · doi:10.1002/cphc.200600638 · Cited by 345
Anomalous Protein Diffusion in Living Cells as Seen by Fluorescence Correlation Spectroscopy
Weiss, M., Hashimoto, H., & Nilsson, T. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75130-3 · Cited by 292
Probing the Nanoscale Viscoelasticity of Intracellular Fluids in Living Cells
Guigas, G., Kalla, C., & Weiss, M. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.099267 · Cited by 281
Practical guidelines for dual-color fluorescence cross-correlation spectroscopy
Bacia, K., & Schwille, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.410 · Cited by 270
Lipid diffusion in planar membranes investigated by fluorescence correlation spectroscopy
Macháň, R., & Hof, M. (2010) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2010.02.014 · Cited by 259
Quantification of α-Synuclein Binding to Lipid Vesicles Using Fluorescence Correlation Spectroscopy
Rhoades, E., Ramlall, T. F., Webb, W. W., & Eliezer, D. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.079251 · Cited by 257
Self-citationSize Effects on Diffusion Processes within Agarose Gels
Fatin-Rouge, N., Starchev, K., & Buffle, J. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74325-8 · Cited by 246
“This assumption is valid for small detector aperture and/or overfilled back-aperture (Hess and Webb, 2002).”
BackgroundVigh, L., Escribá, P. V., Sonnleitner, A., Sonnleitner, M., Piotto, S., Maresca, B., Horváth, I., & Harwood, J. L. (2005) · Progress in Lipid Research · doi:10.1016/j.plipres.2005.08.001 · Cited by 230
Fluorescence Fluctuation Spectroscopy in Subdiffraction Focal Volumes
Kastrup, L., Blom, H., Eggeling, C., & Hell, S. W. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.178104 · Cited by 229
Performance of Fluorescence Correlation Spectroscopy for Measuring Diffusion and Concentration
Enderlein, J., Gregor, I., Patra, D., Dertinger, T., & Kaupp, U. B. (2005) · ChemPhysChem · doi:10.1002/cphc.200500414 · Cited by 221
Tcherniak, A., Dominguez-Medina, S., Chang, W.-S., Swanglap, P., Slaughter, L. S., Landes, C. F., & Link, S. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp206203s · Cited by 207
Holyst, R., Bielejewska, A., Szymański, J., Wilk, A., Patkowski, A., Gapiński, J., Żywociński, A., Kalwarczyk, T., Kalwarczyk, E., Tabaka, M., et al. (2009) · Physical Chemistry Chemical Physics · doi:10.1039/b908386c · Cited by 195
The Amyloid β Peptide (Aβ1-40) Is Thermodynamically Soluble at Physiological Concentrations
Sengupta, P., Garai, K., Sahoo, B., Shi, Y., Callaway, D. J. E., & Maiti, S. (2003) · Biochemistry · doi:10.1021/bi0341410 · Cited by 167
Seth, S., Mondal, N., Patra, S., & Samanta, A. (2016) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.5b02639 · Cited by 160
Vacuum-assisted cell loading enables shear-free mammalian microfluidic culture
Kolnik, M., Tsimring, L. S., & Hasty, J. (2012) · Lab on a Chip · doi:10.1039/c2lc40569e · Cited by 86
Metadata
- Authors
- Hess, S. T., & Webb, W. W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2002-10
- Volume
- 83
- Issue
- 4
- Pages
- 2300-2317
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1986752048
- Cited by
- 394
- References
- 36
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.