Multiphoton Excitation Provides Optical Sections from Deeper within Scattering Specimens than Confocal Imaging
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Multiphoton excitation fluorescence imaging generates an optical section of sample by restricting fluorophore excitation to the plane of focus. High photon densities, achieved only in the focal volume of the objective, are sufficient to excite the fluorescent probe molecules by density-dependent, multiphoton excitation processes. We present comparisons of confocal with multiphoton excitation imaging of identical optical sections within a sample. These side-by-side comparisons of imaging modes demonstrate a significant advantage of multiphoton imaging; data can be obtained from deeper within biological specimens. Observations on a variety of biological samples showed that in all cases there was at least a twofold improvement in the imaging penetration depth obtained with multiphoton excitation relative to confocal imaging. The more pronounced degradation in image contrast deep within a confocally imaged sample is primarily due to scattered emission photons, which reduce the signal and increase the local background as measurements of point spread functions indicated that resolution does not significantly change with increasing depth for either mode of microscopy. Multiphoton imaging does not suffer from degradation of signal-to-background to nearly the same extent as confocal imaging because this method is insensitive to scatter of the emitted signal. Direct detection of emitted photons using an external photodetector mounted close to the objective (possible only in a multiphoton imaging system) improves system sensitivity and the utilization of scattered emission photons for imaging. We demonstrate that this technique provides yet further improvements in the capability of multiphoton excitation imaging to produce good quality images from deeper within tissue relative to confocal imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Two-Photon Excitation in CaF2:Eu2+
Kaiser, W., & Garrett, C. G. B. (1961) · Physical Review Letters · doi:10.1103/physrevlett.7.229 · Cited by 1,851 · cited 2×
“For two-photon excitation, the excitation rate is proportional to the square of the local beam intensity (Kaiser and Garrett, 1961).”
BackgroundHandbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Dendritic spines as basic functional units of neuronal integration
Yuste, R., & Denk, W. (1995) · Nature · doi:10.1038/375682a0 · Cited by 950
White, J. G., Amos, W. B., & Fordham, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.1.41 · Cited by 858
Self-citationIn vivo dendritic calcium dynamics in neocortical pyramidal neurons
Svoboda, K., Denk, W., Kleinfeld, D., & Tank, D. W. (1997) · Nature · doi:10.1038/385161a0 · Cited by 815
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
Direct measurement of coupling between dendritic spines and shafts
Svoboda, K., Tank, D. W., & Denk, W. (1996) · Science · doi:10.1126/science.272.5262.716 · Cited by 472 · cited 1×
“Thus, physiological experiments can be performed with less perturbation due to imaging (Denk et al., 1994; Denk et al., 1995b; Yuste and Denk, 1995; Svoboda et al., 1996, 1997).”
BackgroundAnatomical and functional imaging of neurons using 2-photon laser scanning microscopy
Denk, W., Delaney, K. R., Gelperin, A., Kleinfeld, D., Strowbridge, B. W., Tank, D. W., & Yuste, R. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90189-9 · Cited by 348
Two types of calcium response limited to single spines in cerebellar Purkinje cells.
Denk, W., Sugimori, M., & Llinás, R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.18.8279 · Cited by 282
Wavelength dependence of cell cloning efficiency after optical trapping
Liang, H., Vu, K. T., Krishnan, P., Trang, T. C., Shin, D., Kimel, S., & Berns, M. W. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79716-3 · Cited by 261
Brakenhoff, G. J., van der Voort, H. T. M., van Spronsen, E. A., Linnemans, W. A. M., & Nanninga, N. (1985) · Nature · doi:10.1038/317748a0 · Cited by 256
Cellular response to near-infrared femtosecond laser pulses in two-photon microscopes
König, K., So, P. T. C., Mantulin, W. W., & Gratton, E. (1997) · Optics Letters · doi:10.1364/ol.22.000135 · Cited by 254
Williams, R. M., Piston, D. W., & Webb, W. W. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.11.8070629 · Cited by 235
Chemistry of Structure-Function Relationships in Cheese
(1995) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-1913-3 · Cited by 174
Confocal microscopy in turbid media
Schmitt, J. M., Knüttel, A., & Yadlowsky, M. J. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002226 · Cited by 153
Mechanisms involved in the generation of free radicals.
Halliwell, B. B. (1996) · PubMed · Cited by 150
Chemistry of Structure-Function Relationships in Cheese
Malin, E. L., & Tunick, M. H. (2012) · Medical Entomology and Zoology · Cited by 138
Stelzer, E. H. K., Hell, S. W., Lindek, S., Stricker, R., Pick, R., Storz, C., Ritter, G., & SALMON, N. J. (1994) · Optics Communications · doi:10.1016/0030-4018(94)90546-0 · Cited by 119
Intravital imaging of green fluorescent protein using two-photon laser-scanning microscopy
Potter, S. M., Wang, C., Garrity, P., & Fraser, S. E. (1996) · Gene · doi:10.1016/0378-1119(95)00681-8 · Cited by 100
Two-photon excitation in functional biological imaging
Denk, W. T. (1996) · Journal of Biomedical Optics · doi:10.1117/12.242945 · Cited by 98
All-solid-state ultrafast lasers facilitate multiphoton excitation fluorescence imaging
Wokosin, D. L., Centonze, V., White, J. G., Armstrong, D., Robertson, G., & Ferguson, A. I. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577337 · Cited by 37
Self-citation
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Collagen reorganization at the tumor-stromal interface facilitates local invasion
Provenzano, P. P., Eliceiri, K. W., Campbell, J. M., Inman, D. R., White, J. G., & Keely, P. J. (2006) · BMC Medicine · doi:10.1186/1741-7015-4-38 · Cited by 1,804
Self-citationFluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,355
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Metadata
- Authors
- Centonze, V. E., & White, J. G.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-10
- Volume
- 75
- Issue
- 4
- Pages
- 2015-2024
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2042194419
- Cited by
- 460
- References
- 23
- FWCI
- 12.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.