Multiphoton Excitation Provides Optical Sections from Deeper within Scattering Specimens than Confocal Imaging
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Multiphoton excitation fluorescence imaging generates an optical section of sample by restricting fluorophore excitation to the plane of focus. High photon densities, achieved only in the focal volume of the objective, are sufficient to excite the fluorescent probe molecules by density-dependent, multiphoton excitation processes. We present comparisons of confocal with multiphoton excitation imaging of identical optical sections within a sample. These side-by-side comparisons of imaging modes demonstrate a significant advantage of multiphoton imaging; data can be obtained from deeper within biological specimens. Observations on a variety of biological samples showed that in all cases there was at least a twofold improvement in the imaging penetration depth obtained with multiphoton excitation relative to confocal imaging. The more pronounced degradation in image contrast deep within a confocally imaged sample is primarily due to scattered emission photons, which reduce the signal and increase the local background as measurements of point spread functions indicated that resolution does not significantly change with increasing depth for either mode of microscopy. Multiphoton imaging does not suffer from degradation of signal-to-background to nearly the same extent as confocal imaging because this method is insensitive to scatter of the emitted signal. Direct detection of emitted photons using an external photodetector mounted close to the objective (possible only in a multiphoton imaging system) improves system sensitivity and the utilization of scattered emission photons for imaging. We demonstrate that this technique provides yet further improvements in the capability of multiphoton excitation imaging to produce good quality images from deeper within tissue relative to confocal imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Two-Photon Excitation in CaF2:Eu2+
Kaiser, W., & Garrett, C. G. B. (1961) · Physical Review Letters · doi:10.1103/physrevlett.7.229 · Cited by 1,851 · cited 2×
“For two-photon excitation, the excitation rate is proportional to the square of the local beam intensity (Kaiser and Garrett, 1961).”
BackgroundHandbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Dendritic spines as basic functional units of neuronal integration
Yuste, R., & Denk, W. (1995) · Nature · doi:10.1038/375682a0 · Cited by 950
White, J. G., Amos, W. B., & Fordham, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.1.41 · Cited by 858
Self-citationIn vivo dendritic calcium dynamics in neocortical pyramidal neurons
Svoboda, K., Denk, W., Kleinfeld, D., & Tank, D. W. (1997) · Nature · doi:10.1038/385161a0 · Cited by 815
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
Direct measurement of coupling between dendritic spines and shafts
Svoboda, K., Tank, D. W., & Denk, W. (1996) · Science · doi:10.1126/science.272.5262.716 · Cited by 472 · cited 1×
“Thus, physiological experiments can be performed with less perturbation due to imaging (Denk et al., 1994; Denk et al., 1995b; Yuste and Denk, 1995; Svoboda et al., 1996, 1997).”
BackgroundAnatomical and functional imaging of neurons using 2-photon laser scanning microscopy
Denk, W., Delaney, K. R., Gelperin, A., Kleinfeld, D., Strowbridge, B. W., Tank, D. W., & Yuste, R. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90189-9 · Cited by 348
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Collagen reorganization at the tumor-stromal interface facilitates local invasion
Provenzano, P. P., Eliceiri, K. W., Campbell, J. M., Inman, D. R., White, J. G., & Keely, P. J. (2006) · BMC Medicine · doi:10.1186/1741-7015-4-38 · Cited by 1,804
Self-citationFluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,355
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Two-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Skala, M. C., Riching, K. M., Gendron-Fitzpatrick, A., Eickhoff, J., Eliceiri, K. W., White, J. G., & Ramanujam, N. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708425104 · Cited by 1,001
Self-citationClearSee: a rapid optical clearing reagent for whole-plant fluorescence imaging
Kurihara, D., Mizuta, Y., Sato, Y., & Higashiyama, T. (2015) · Development · doi:10.1242/dev.127613 · Cited by 602
Photobleaching in Two-Photon Excitation Microscopy
Patterson, G. H., & Piston, D. W. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76762-2 · Cited by 527
Intracellular Coenzymes as Natural Biomarkers for Metabolic Activities and Mitochondrial Anomalies
Heikal, A. A. (2010) · Biomarkers in Medicine · doi:10.2217/bmm.10.1 · Cited by 458
Unravelling the complexity of metastasis — molecular understanding and targeted therapies
Sethi, N., & Kang, Y. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3125 · Cited by 397
Skala, M. C., Riching, K. M., Bird, D. K., Gendron-Fitzpatrick, A., Eickhoff, J., Eliceiri, K. W., Keely, P. J., & Ramanujam, N. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2717503 · Cited by 380
Multiphoton microscopy in biological research
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00241-6 · Cited by 370
Imaging in vivo: watching the brain in action
Kerr, J. N. D., & Denk, W. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2338 · Cited by 346
Two-Photon Microscopy of Cells and Tissue
Rubart, M. (2004) · Circulation Research · doi:10.1161/01.res.0000150593.30324.42 · Cited by 339
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Two-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311
Functional studies of the kidney of living animals using multicolor two-photon microscopy
Dunn, K. W., Sandoval, R. M., Kelly, K. J., Dagher, P. C., Tanner, G. A., Atkinson, S. J., Bacallao, R. L., & Molitoris, B. A. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00159.2002 · Cited by 311
Fluorescence Proteins, Live-Cell Imaging, and Mechanobiology: Seeing Is Believing
Wang, Y., Shyy, J. Y.-J., & Chien, S. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.010308.161731 · Cited by 310
Depth Penetration and Detection of pH Gradients in Biofilms by Two-Photon Excitation Microscopy
Vroom, J. M., De Grauw, K. J., Gerritsen, H. C., Bradshaw, D. J., Marsh, P. D., Watson, G. K., Birmingham, J. J., & Allison, C. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.8.3502-3511.1999 · Cited by 303
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Yu, Q., & Heikal, A. A. (2009) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2008.12.010 · Cited by 288
Patterson, G. H., Knobel, S. M., Arkhammar, P., Thastrup, O., & Piston, D. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.090098797 · Cited by 284
Four-Dimensional Migratory Coordinates of GABAergic Interneurons in the Developing Mouse Cortex
Ang, E. S. B. C., Haydar, T. F., Gluncic, V., & Rakic, P. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-13-05805.2003 · Cited by 282
“We took advantage of the reduced phototoxicity and increased tissue penetration (Denk et al., 1990; Centonze and White, 1998) inherent in multiphoton live imaging to analyze the migration patterns of GE-derived cells from global, regional, and local perspectives.”
BackgroundHigh-resolution three-photon biomedical imaging using doped ZnS nanocrystals
Yu, J. H., Kwon, S.-H., Petrášek, Z., Park, O. K., Jun, S. W., Shin, K., Choi, M., Park, Y. I., Park, K., Na, H. B., et al. (2013) · Nature Materials · doi:10.1038/nmat3565 · Cited by 276
Imaging living cells and tissues by two-photon excitation microscopy
Piston, D. (1999) · Trends in Cell Biology · doi:10.1016/s0962-8924(98)01432-9 · Cited by 244
Mitotic spindle rotation and mode of cell division in the developing telencephalon
Haydar, T. F., Ang, E., & Rakic, P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0437969100 · Cited by 237
CARDIAC REGENERATION: Repopulating the Heart
Rubart, M., & Field, L. J. (2006) · Annual Review of Physiology · doi:10.1146/annurev.physiol.68.040104.124530 · Cited by 235
Chronic Cellular Imaging of Entire Cortical Columns in Awake Mice Using Microprisms
Andermann, M. L., Gilfoy, N. B., Goldey, G. J., Sachdev, R. N. S., Wölfel, M., McCormick, D. A., Reid, R. C., & Levene, M. J. (2013) · Neuron · doi:10.1016/j.neuron.2013.07.052 · Cited by 227
Physiological Coupling of Donor and Host Cardiomyocytes After Cellular Transplantation
Rubart, M., Pasumarthi, K. B. S., Nakajima, H., Soonpaa, M. H., Nakajima, H. O., & Field, L. J. (2003) · Circulation Research · doi:10.1161/01.res.0000075089.39335.8c · Cited by 221
Skop, A. R., Bergmann, D., Mohler, W. A., & White, J. G. (2001) · Current Biology · doi:10.1016/s0960-9822(01)00231-7 · Cited by 221
Self-citationTwo‐photon fluorescence absorption and emission spectra of dyes relevant for cell imaging
Bestvater, F., Spiess, E., Stobrawa, G., Hacker, M., Feurer, T., Porwol, T., Berchner‐Pfannschmidt, U., Wotzlaw, C., & Acker, H. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01074.x · Cited by 215
Provenzano, P. P., Eliceiri, K. W., & Keely, P. J. (2009) · Clinical & Experimental Metastasis · doi:10.1007/s10585-008-9204-0 · Cited by 202
“Excitation naturally remains restricted to the plane of focus (optically sectioned) because the probability of two or more photons simultaneously exciting a fluorophore outside the focal volume is extremely low [18, 19].”
BackgroundFrom molecular structure to tissue architecture: collagen organization probed by SHG microscopy
Cicchi, R., Vogler, N., Kapsokalyvas, D., Dietzek, B., Popp, J., & Pavone, F. S. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200092 · Cited by 192
Protease sensors for bioimaging
Funovics, M., Weissleder, R., & Tung, C.-H. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2199-0 · Cited by 186
Multi-photon excitation microscopy
Diaspro, A., Bianchini, P., Vicidomini, G., Faretta, M., Ramoino, P., & Usai, C. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-36 · Cited by 185
Influence of optical properties on two-photon fluorescence imaging in turbid samples
Dunn, A. K., Wallace, V. P., Coleno, M., Berns, M. W., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.001194 · Cited by 182
Near infrared imaging with nanoparticles
Altınoğlu, E. İ., & Adair, J. H. (2010) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.77 · Cited by 178
Pampaloni, F., Ansari, N., & Stelzer, E. H. K. (2013) · Cell and Tissue Research · doi:10.1007/s00441-013-1589-7 · Cited by 177
Garner, L. E., Park, J., Dyar, S. M., Chworos, A., Sumner, J. J., & Bazan, G. C. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1016156 · Cited by 162
Metadata
- Authors
- Centonze, V. E., & White, J. G.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-10
- Volume
- 75
- Issue
- 4
- Pages
- 2015-2024
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2042194419
- Cited by
- 460
- References
- 23
- FWCI
- 12.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.