Blood flow distributions by microsphere deposition methods
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The art and science of the use of deposition markers for the estimation of blood flow distributions throughout the body and within organs is reviewed. Development of diffusible tracer techniques started 50 years ago. Twenty years later, radioactive 15 micron microspheres became the standard marker. Early studies on small animals, fetal sheep in 1967 and rats in 1976, provoked much of the technical development. Needs for avoiding the use of radioactivity, for having long lasting labels, and for providing higher spatial resolution, are driving the continuing exploration of newer techniques using colored and fluorescent microspheres and molecular deposition markers. Strengths and weaknesses of the various methods are compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The unbiased estimation of number and sizes of arbitrary particles using the disector
Sterio, D. C. (1984) · Journal of Microscopy · doi:10.1111/j.1365-2818.1984.tb02501.x · Cited by 2,519 · cited 1×
“Using methods of quantitative histology [55–57] it should be possible to quantitate perfusion to whole organs as well as intraorgan structures at a level not previously possible.”
MethodBlood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
Gundersen, H. J. G. (1986) · PubMed · Cited by 1,658
Gundersen, H. J. G. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb02764.x · Cited by 1,429 · cited 1×
“Using methods of quantitative histology [55–57] it should be possible to quantitate perfusion to whole organs as well as intraorgan structures at a level not previously possible.”
MethodRUDOLPH, A. M., & HEYMANN, M. A. (1967) · Circulation Research · doi:10.1161/01.res.21.2.163 · Cited by 1,316 · cited 3×
“For these reasons the radioactive microsphere technique, introduced in 1967 by Rudolph and Heymann [1] for examining regional blood flow in sheep fetuses in utero, became an essential tool in cardiovascular research.”
BackgroundMethodSome sources of error in measuring regional blood flow with radioactive microspheres.
Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffman, J. I., Archie, J. P., & Fixler, D. E. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.4.598 · Cited by 1,132 · cited 2×
“[6] and, later, other investigators [7–11] showed that accurate assessment of tissue blood flow requires a sufficient number of micro spheres per sample, 200 to 400 for 10% accuracy.”
BackgroundDOMENECH, R. J., HOFFMAN, J. I., NOBLE, M. I., SAUNDERS, K. B., HENSON, J. R., & SUBIJANTO, S. (1969) · Circulation Research · doi:10.1161/01.res.25.5.581 · Cited by 670 · cited 2×
“[25], Yipintsoi et al.”
BackgroundCk, F. (1970) · PubMed · Cited by 641
Measurement of regional myocardial blood flow with multiple colored microspheres.
Kowallik, P., Schulz, R., Guth, B. D., Schade, A., Paffhausen, W., Gross, R., & Heusch, G. (1991) · Circulation · doi:10.1161/01.cir.83.3.974 · Cited by 375
Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
Glenny, R. W., Bernard, S., & Brinkley, M. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2585 · Cited by 365 · cited 5×
“99) [50] (ischemic and non-ischemic), myocardium [13] and a variety of other organs [13,50].”
BackgroundMethodInfluentialStability of heterogeneity of myocardial blood flow in normal awake baboons.
King, R. B., Bassingthwaighte, J. B., Hales, J. R. S., & Rowell, L. B. (1985) · Circulation Research · doi:10.1161/01.res.57.2.285 · Cited by 255 · cited 2×
“For systemic flows, injection into the left atrium (preferably) or left ventricular apical region gave satisfactory mixing, and these sites differed little from each other even for coronary flow measurement [28].”
BackgroundUTLEY, J., CARLSON, E. L., HOFFMAN, J. I. E., MARTINEZ, H. M., & BUCKBERG, G. D. (1974) · Circulation Research · doi:10.1161/01.res.34.3.391 · Cited by 210
Yipintsoi, T., Dobbs, W. A., Scanlon, P. D., Knopp, T. J., & Bassingthwaighte, J. B. (1973) · Circulation Research · doi:10.1161/01.res.33.5.573 · Cited by 205 · cited 2×
“The use of the 15 micron diameter spheres established the fact that regional myocardial flows were markedly heterogeneous [26], affirming the impressions gained from diffusible indicator studies using 86Rb [18,27].”
MethodEffect of velocity distribution on red cell distribution in capillary blood vessels
Yen, R. T., & Fung, Y. C. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.2.h251 · Cited by 157 · cited 1×
“In theory, some separation is expected due to their stiffness and their size [37].”
BackgroundValidity of microsphere depositions for regional myocardial flows
Bassingthwaighte, J. B., Malone, M. A., Moffett, T. C., King, R. B., Little, S. E., Link, J. M., & Krohn, K. A. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.1.h184 · Cited by 123 · cited 1×
“However, the artifact is apparently inconsequential, because a comparison between microspheres and an almost entirely extracted molecular marker, 131I-desmethylimipramine [14,38], showed almost the same distributions in cardiac tissues for both kinds of markers.”
Backgroundvan Oosterhout, M. F. M., Willigers, H. M., Reneman, R. S., & Prinzen, F. W. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.2.h725 · Cited by 113
Self-citationDevelopments in non-radioactive microsphere techniques for blood flow measurement
Prinzen, F. W., & Glenny, R. W. (1994) · Cardiovascular Research · doi:10.1093/cvr/28.10.1467 · Cited by 104
Self-citationMeasurement of organ blood flow with coloured microspheres in the rat
Hakkinen, J. P., Miller, M. W., Smith, A. H., & Knight, D. R. (1995) · Cardiovascular Research · doi:10.1016/0008-6363(96)88549-x · Cited by 104
Pancreatic islet blood flow in normal and obese-hyperglycemic (ob/ob) mice
Carlsson, P. O., Andersson, A., & Jansson, L. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e990 · Cited by 69
Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements
van Oosterhout, M. F. M., Prinzen, F. W., Sakurada, S., Glenny, R. W., & Hales, J. R. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.1.h110 · Cited by 59 · cited 5×
“The most convincing indication of leaching of radioisotope labels from microspheres was a comparison between radioactive and fluorescent microspheres [45]: two sets of radioactive and two sets of fluorescent spheres were injected simultaneously in rabbits.”
BackgroundInfluentialSelf-citationA new sample-processing unit for the fluorescent microsphere method
Raab, S., Thein, E., Harris, A. G., & Meßmer, K. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.5.h1801 · Cited by 58 · cited 1×
“A recently developed robot system even integrates tissue digestion, microsphere isolation and fluorimetry in one system [53].”
BackgroundOn the validity of blood flow measurement using colored microspheres
Hodeige, D., Pauw, M. D., Eechaute, W., Weyne, J., & Heyndrickx, G. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.4.h1150 · Cited by 54 · cited 3×
“Colored microspheres have the disadvantages that the spectra from the different colors overlap [49] and that the sensitivity to detect the colors by spectroscopy is limited [51].”
BackgroundMethodSplanchnic and systemic hemodynamics in mice using a radioactive microsphere technique
Sarin, S. K., Sabbà, C., & Groszmann, R. J. (1990) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1990.258.3.g365 · Cited by 50 · cited 3×
“In smaller animals, injections in the ascending aorta have been used for studies on flow distribution in abdominal organs [29,30], but this is not adequate for obtaining estimates of cardiac output or of cerebral or myocardial flows.”
BackgroundInfluentialDaemen, M. J. A. P., Thijssen, H. H. W., van Essen, H., Vervoort-Peters, H. T. M., Prinzen, F. W., Struijker-Boudier, H. A. J., & Smits, J. F. M. (1989) · Journal of Pharmacological Methods · doi:10.1016/0160-5402(89)90066-1 · Cited by 49
Self-citationEffects of acute cold exposure on the distribution of cardiac output in the sheep
Hales, J. R. S., Bennett, J. W., & Fawcett, A. A. (1976) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00585871 · Cited by 37
Wieland, W., Wouters, P. F., Aken, H. V., & Flameng, W. J. (2002) · Computers in cardiology · doi:10.1109/cic.1993.378308 · Cited by 30
Use of fluorescent latex microspheres to measure coronary blood flow distribution.
Abel, F. L., Rh, C., & Rr, B. (1993) · PubMed · Cited by 27
Stanek, K. A., Coleman, T. G., Smith, T. L., & Murphy, W. R. C. (1985) · Journal of Pharmacological Methods · doi:10.1016/0160-5402(85)90055-5 · Cited by 20 · cited 3×
“Instead of dextran, other macromolecular solutions, such as Ficoll/Isopaque or plasma replacement solutions, can be used [13,61].”
BackgroundMethodObservations on the validity of using ?NEN-TRAC? microspheres for measuring organ blood flow
Hales, J. R. S., King, R. B., & Fawcett, A. A. (1979) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581435 · Cited by 14
Cited by
Vollmar, B., & Menger, M. D. (2009) · Physiological Reviews · doi:10.1152/physrev.00027.2008 · Cited by 500
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Nishida, T., Shimokawa, H., Oi, K., Tatewaki, H., Uwatoku, T., Abe, K., Matsumoto, Y., Kajihara, N., Eto, M., Matsuda, T., et al. (2004) · Circulation · doi:10.1161/01.cir.0000148849.51177.97 · Cited by 381
Left bundle branch block induces ventricular remodelling and functional septal hypoperfusion
Vernooy, K., Verbeek, X. A. A. M., Peschar, M., Crijns, H. J. G. M., Arts, T., Cornelussen, R. N. M., & Prinzen, F. W. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi008 · Cited by 357
Self-citationHow to assess intestinal viability during surgery: A review of techniques
Urbanavičius, L. (2011) · World Journal of Gastrointestinal Surgery · doi:10.4240/wjgs.v3.i5.59 · Cited by 235
Metadata
- Authors
- Prinzen, F.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-01-01
- Volume
- 45
- Issue
- 1
- Pages
- 13-21
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2032901124
- Cited by
- 182
- References
- 29
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.