Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283 · cited 1×
“Second, a unique Young’s modulus for all tissues was used in the model, whereas several investigators have found that the trabecular tissue properties are less than those of cortical bone (Rho et al., 1993; Choi et al., 1990; Kuhn et al., 1989).”
MethodThe direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071 · cited 2×
“These techniques were based on high-resolution imaging techniques, such as serial sectioning (Odgaard et al., 1994) or micro-CT scanning (Feldkamp et al., 1989; Rüegsegger et al., 1996), in combination with newly developed, iterative FE-solvers (Hollister and Kikuchi, 1993; Van Rietbergen et al.,…”
BackgroundMethodA microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Self-citationvan Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865 · cited 4×
“…were based on high-resolution imaging techniques, such as serial sectioning (Odgaard et al., 1994) or micro-CT scanning (Feldkamp et al., 1989; Rüegsegger et al., 1996), in combination with newly developed, iterative FE-solvers (Hollister and Kikuchi, 1993; Van Rietbergen et al., 1995, 1996).”
MethodInfluentialSelf-citationChoi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532 · cited 1×
“Second, a unique Young’s modulus for all tissues was used in the model, whereas several investigators have found that the trabecular tissue properties are less than those of cortical bone (Rho et al., 1993; Choi et al., 1990; Kuhn et al., 1989).”
MethodRelationships between loading history and femoral cancellous bone architecture
Carter, D. R., Orr, T. E., & Fyhrie, D. P. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90091-2 · Cited by 426 · cited 2×
“…to multiple load directions is also supported by the results of earlier load adaptive bone remodeling simulation studies, where it was found that multiple femoral loads are required to reproduce the natural bone density in a computer model of the femur (Carter et al., 1989; Weinans et al., 1992).”
ResultHollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322 · cited 3×
“…studies, a homogenization sampling procedure, incorporating large-scale FE-models representing small samples of trabecular bone in detail, was applied to obtain the trabecular tissue stresses throughout larger pieces of bones or whole joints (Hollister et al., 1993; Hollister and Goldstein, 1993).”
MethodA comparison of the fatigue behavior of human trabecular and cortical bone tissue
Choi, K., & Goldstein, S. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90051-2 · Cited by 247 · cited 4×
“The average tissue stress was 3.88 MPa, the standard deviation 3.04 MPa and the largest value found was 60.2 MPa.”
BackgroundInfluentialEffects of material properties of femoral hip components on bone remodeling
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100614 · Cited by 194 · cited 2×
“…to multiple load directions is also supported by the results of earlier load adaptive bone remodeling simulation studies, where it was found that multiple femoral loads are required to reproduce the natural bone density in a computer model of the femur (Carter et al., 1989; Weinans et al., 1992).”
ResultSelf-citationWeinans, H., Huiskes, R., Van Rietbergen, B., Sumner, D. R., Turner, T. M., & Galante, J. O. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110405 · Cited by 194 · cited 1×
“The values and distribution of the SED in the cortical region are very similar to those determined in earlier studies, using continuum models of a canine femur (Weinans et al., 1993).”
ResultSelf-citationComparison of the trabecular and cortical tissue moduli from human iliac crests
Kuhn, J. L., Goldstein, S. A., Choi, R., London, M., Feldkamp, L. A., & Matthews, L. S. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070614 · Cited by 164 · cited 1×
“Second, a unique Young’s modulus for all tissues was used in the model, whereas several investigators have found that the trabecular tissue properties are less than those of cortical bone (Rho et al., 1993; Choi et al., 1990; Kuhn et al., 1989).”
MethodCOMPUTATIONAL STRATEGIES FOR ITERATIVE SOLUTIONS OF LARGE FEM APPLICATIONS EMPLOYING VOXEL DATA
VAN RIETBERGEN, B., WEINANS, H., HUISKES, R., & POLMAN, B. J. W. (1996) · International Journal for Numerical Methods in Engineering · doi:10.1002/(sici)1097-0207(19960830)39:16<2743::aid-nme974>3.0.co;2-a · Cited by 135 · cited 7×
“More recent studies have used new techniques that enable the FE-analysis of realistic trabecular architectures in detail (Fyhrie et al., 1992; Hollister et al., 1993; Van Rietbergen et al., 1995).”
MethodInfluentialSelf-citationFinite Element Analysis of a Three-Dimensional Open-Celled Model for Trabecular Bone
Beaupre, G. S., & Hayes, W. C. (1985) · Journal of Biomechanical Engineering · doi:10.1115/1.3138550 · Cited by 102 · cited 2×
“In an early study, trabecular architecture was represented as a repetitive structure of unit cells (Beaupré and Hayes, 1985).”
BackgroundCamacho, D., Hopper, R. H., Lin, G. M., & Myers, B. S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00073-0 · Cited by 98 · cited 1×
“It has been shown that this can lead to errors in the stress-strain calculations, resulting in oscillating values, in particular at the bone surfaces (Jacobs et al., 1993; Guldberg and Hollister, 1994, Camacho et al., 1997).”
Backgroundvon Eisenhart‐Rothe, R., Eckstein, F., Müller‐Gerbl, M., Landgraf, J., Rock, C., & Putz, R. V. (1997) · Anatomy and Embryology · doi:10.1007/s004290050047 · Cited by 75 · cited 2×
“calculated from three orthogonal hip-joint forces was based on recent findings that the contact areas in the human hip-joint are located near the periphery of the cup with no contact in the region near the center of the acetabular cup where the femoral fovea and the round ligament inhibit contact (Eisenhart-Rothe et a…”
BackgroundBay, B. K., Hamel, A. J., Olson, S. A., & Sharkey, N. A. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00120-0 · Cited by 70 · cited 1×
“…in the region near the center of the acetabular cup where the femoral fovea and the round ligament inhibit contact (Eisenhart-Rothe et al., 1997; Bay et al., 1997), and on the observation that the anatomy of the pelvis favors load transfer in orthogonal directions rather than in other…”
BackgroundThree-dimensional reconstruction of entire vertebral bodies
Odgaard, A., Andersen, K., Ullerup, R., Frich, L. H., & Melsen, F. (1994) · Bone · doi:10.1016/8756-3282(94)90297-6 · Cited by 51 · cited 2×
“These techniques were based on high-resolution imaging techniques, such as serial sectioning (Odgaard et al., 1994) or micro-CT scanning (Feldkamp et al.”
MethodPidaparti, R. M. V., & Turner, C. H. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00052-3 · Cited by 46 · cited 3×
“…unidirectional loading, can only explain the existence of orthogonal architectures, it was suggested in these studies that an optimal cancellous structure may appear differently under multidirectional joint loads than the ‘trajectorial’ organization proposed by Wolff (Pidaparti and Turner, 1997).”
BackgroundResult
Cited by
Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
Huiskes, R., Ruimerman, R., van Lenthe, G. H., & Janssen, J. D. (2000) · Nature · doi:10.1038/35015116 · Cited by 1,180
Self-citationBiomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
3D bioprinting of tissues and organs for regenerative medicine
Vijayavenkataraman, S., Yan, W.-C., Lu, W. F., Wang, C.-H., & Fuh, J. Y. H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.004 · Cited by 630
Boutroy, S., Van Rietbergen, B., Sornay-Rendu, E., Munoz, F., Bouxsein, M. L., & Delmas, P. D. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.071108 · Cited by 470
Self-citation
Metadata
- Authors
- Van Rietbergen, B., Müller, R., Ulrich, D., Rüegsegger, P., & Huiskes, R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-02
- Volume
- 32
- Issue
- 2
- Pages
- 165-173
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2097521805
- Cited by
- 170
- References
- 18
- FWCI
- 10.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.