First-Trimester down syndrome screening using dried blood biochemistry and nuchal translucency
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the effectiveness of free beta-hCG, pregnancy-associated plasma protein A, and nuchal translucency in a prospective first-trimester prenatal screening study for Down syndrome and trisomy 18. METHODS: Risks were calculated for Down syndrome and trisomy 18 based on maternal age and biochemistry only (n = 10,251), nuchal translucency only (n = 5809), and the combination of nuchal translucency and biochemistry (n = 5809). RESULTS: The study population included 50 Down syndrome and 20 trisomy 18 cases. Nuchal translucency measurement was done on 33 Down syndrome and 13 trisomy 18 cases. Down syndrome screening using combined biochemistry and ultrasound resulted in a false-positive rate of 4.5% (95% confidence interval [CI] 3.9%, 5.2%) and detection rate of 87.5% (95% CI 47%, 100%) in patients under age 35 years. In older patients, the false-positive rate was 14.3% (95% CI 12.7%, 15. 8%) and detection rate was 92% (95% CI 74%, 99%). For trisomy 18 screening, the false-positive rate was 0.4% (95% CI 0.24%, 0.69%) and detection rate was 100% (95% CI 40%, 100%) in younger patients, whereas in older patients the false-positive rate was 1.4% (95% CI 0. 9%, 2.0%) and detection rate was 100% (95% CI 66%, 100%). Using modeling, at a fixed 5% false-positive rate, the Down syndrome detection rate was 91%. Conversely, at a fixed 70% Down syndrome detection rate, the false-positive rate was 1.4%. CONCLUSION: First-trimester screening for Down syndrome and trisomy 18 is effective and offers substantial benefits to clinicians and patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Spencer, K., Souter, V., Tul, N., Snijders, R., & Nicolaides, K. H. (1999) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1999.13040231.x · Cited by 568
Wald, N. J., Watt, H. C., & Hackshaw, A. K. (1999) · New England Journal of Medicine · doi:10.1056/nejm199908123410701 · Cited by 530
Souka, A. P., Snijders, R. J. M., Novakov, A., Soares, W., & Nicolaides, K. H. (1998) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1998.11060391.x · Cited by 479 · cited 1×
“Undoubtedly, ultrasound examinations done during the first trimester of pregnancy will lead to the detection of other fetal abnormalities as well.(24) Although concerns have been raised about the cost of ultrasound, it has been argued that ultrasound examinations should be done on all gravidas before secondtrimester t…”
BackgroundPrenatal Screening for Down's Syndrome with Use of Maternal Serum Markers
Haddow, J. E., Palomaki, G. E., Knight, G. J., Williams, J., Pulkkinen, A., Canick, J. A., Saller, D. N., & Bowers, G. B. (1992) · New England Journal of Medicine · doi:10.1056/nejm199208273270902 · Cited by 454
Pandya, P. P., Snijders, R. J. M., Johnson, S. P., de Lourdes Brizot, M., & Nicolaids, K. H. (1995) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1995.tb10902.x · Cited by 411
Severe limb abnormalities after chorion villus sampling at 56-66 days' gestation
Firth, H. V., Boyd, P. A., Lindenbaum, R. H., Huson, S. M., Chamberlain, P., & Mackenzie, I. Z. (1991) · The Lancet · doi:10.1016/0140-6736(91)91374-4 · Cited by 380 · cited 1×
“After the initial introduction of CVS, reports indicated an increased incidence of fetal complications, including specific limb defects.(16,17) However, more recent studies showed lower rates of limbreduction defects if CVS is done at 10 weeks or later.”
Maternal age‐ and gestation‐specific risk for trisomy 21
Snijders, R. J. M., Sundberg, K., Holzgreve, W., Henry, G., & Nicolaides, K. H. (1999) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.1999.13030167.x · Cited by 367 · cited 3×
“Risks were determined by multiplying the likelihood ratio by the women’s risk for Down syndrome and trisomy 18 before screening, which was based on maternal age14 and gestational age, using the formula of Snidjers et al.15 If blood collection and nuchal translucency measurement were not done on the same day, the later…”
MethodInfluentialRandomised trial to assess safety and fetal outcome of early and midtrimester amniocentesis
(1998) · The Lancet · doi:10.1016/s0140-6736(97)12346-7 · Cited by 318
Nicolaides, K., Brizot, M., Patel, F., & Snijders, R. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91769-8 · Cited by 271 · cited 1×
“Similarly, there are reports concerning the safety of early amniocentesis.(19,20) On balance, it is likely that both CVS and early amniocentesis will result in similar low but acceptable risks for patients who have been given appropriate preprocedure counseling.”
BackgroundFetal loss in Down syndrome pregnancies
Morris, J. K., Wald, N. J., & Watt, H. (1999) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199902)19:2<142::aid-pd486>3.0.co;2-7 · Cited by 253
Screening of Maternal Serum for Fetal Down's Syndrome in the First Trimester
Haddow, J. E., Palomaki, G. E., Knight, G. J., Williams, J., Miller, W. A., & Johnson, A. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804023381404 · Cited by 232
First‐trimester screening for fetal aneuploidy: biochemistry and nuchal translucency
Orlandi, F., Damiani, G. B., Hallaban, T. W., Krantz, D., & Macri, J. N. (1997) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1997.10060381.x · Cited by 112 · cited 1×
“Dried blood specimens were analyzed for free b-hCG and pregnancy-associated plasma protein A by using previously described enzyme-linked immunosorbent assay procedures.(6) Of 10,251 specimens, 7801 were assayed at NTD Laboratories (Huntington Station, NY) and 2450 were assayed at Centro Di Diagnosi Prenatale (Palermo,…”
MethodSelf-citationHecht, C., & Hook, E. B. (1994) · Prenatal Diagnosis · doi:10.1002/pd.1970140814 · Cited by 86
Wald, N. J., Watt, H., & Hackshaw, A. K. (2000) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-200001000-00006 · Cited by 49
Cited by
Screening for fetal aneuploidies at 11 to 13 weeks
Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2637 · Cited by 642
Nuchal translucency and other first-trimester sonographic markers of chromosomal abnormalities
Nicolaides, K. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.090 · Cited by 626
First-Trimester Screening for Trisomies 21 and 18
Wapner, R., Thom, E., Simpson, J. L., Pergament, E., Silver, R., Filkins, K., Platt, L., Mahoney, M., Johnson, A., Hogge, W. A., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa025273 · Cited by 563
Self-citationIncreased nuchal translucency with normal karyotype
Souka, A. P., von Kaisenberg, C. S., Hyett, J. A., Sonek, J. D., & Nicolaides, K. H. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.093 · Cited by 517
Spencer, K., Spencer, C. E., Power, M., Dawson, C., & Nicolaides, K. H. (2003) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1046/j.1471-0528.2003.02246.x · Cited by 305
Metadata
- Authors
- Krantz, D.
- Venue
- Obstetrics & Gynecology
- Published
- 2000-08
- Volume
- 96
- Issue
- 2
- Pages
- 207-213
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2123364225
- Cited by
- 168
- References
- 15
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.